Ronny Peter

Dr. Ronny Peter

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2005 in Physical Review E
Verified
Journal Article
Open access
PDF file
RPRonny Peter
Ronny Peter
MHM. Hilt
M. Hilt
FZF. Ziebert
F. Ziebert
JBJ. Bammert
J. Bammert
CEC. Erlenkämper
C. Erlenkämper
WZW. Zimmermann
W. Zimmermann
We investigate the response of two-dimensional pattern-forming systems with a broken up-down symmetry, such as chemical reactions, to spatially resonant forcing and propose related experiments. The nonlinear behavior immediately above threshold is analyzed in terms of amplitude equations suggested for a 1:2 and 1:1 ratio between the wavelength of the spatial periodic forcing and the wavelength of the pattern of the respective system. Both sets of coupled amplitude equations are derived by a perturbative method from the Lengyel-Epstein model describing a chemical reaction showing Turing patterns, which gives us the opportunity to relate the generic response scenarios to a specific pattern-forming system. The nonlinear competition between stripe patterns and distorted hexagons is explored and their range of existence, stability, and coexistence is determined. Whereas without modulations hexagonal patterns are always preferred near onset of pattern formation, single-mode solutions (stripes) are favored close to threshold for modulation amplitudes beyond some critical value. Hence distorted hexagons only occur in a finite range of the control parameter and their interval of existence shrinks to zero with increasing values of the modulation amplitude. Furthermore, depending on the modulation amplitude, the transition between stripes and distorted hexagons is either subcritical or supercritical.

25 April 2019 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
RPRonny Peter
Ronny Peter
GFGerhard Fischerauer
Gerhard Fischerauer
The cavity perturbation method is a standard technique for material parameter estimation. It typically assumes that the sample consisting of the material under test (MUT) is small. This and other assumptions are violated in in-process measurement scenarios that involve big and inhomogeneous samples. We analyze the limitations of the classical perturbation method and present a new approach toward the measurement of spatially varying material parameters associated with a large sample in a rectangular or a circular cylindrical microwave cavity. The method is based on the measurement of multiple resonance frequencies and quality factors and is validated by numerical and laboratory experiments. It is demonstrated that relative permittivities and conductivities may be measured with typical accuracies on the order of 1%.

23 March 2023 in TM - Technisches Messen
Verified
Journal Article
Closed access
LBLuca Bifano
Luca Bifano
VMValentin Meiler
Valentin Meiler
RPRonny Peter
Ronny Peter
GFGerhard Fischerauer
Gerhard Fischerauer
The detection of microplastics in water requires a series of processes (sample collection, purification, and preparation) until a sample can be analyzed in the laboratory. To shorten this process chain, we are investigating whether electrical impedance spectroscopy (EIS) enhanced by a classifier based on support vector machine (SVM) can be applied to the problem of microplastics detection. Results with suspensions of polypropylene (PP) and polyolefin (PO) in deionized water proved promising: The relative permittivities extracted from the measured impedances agree with literature data. The subsequent classification of measured impedances by SVM shows that the three classes “no plastic” (below the detection limit of 1 g plastic per filling), “PP” and “PO” can be distinguished securely independent of the background medium water. Mixtures of PO and PP were not examined, i.e. either PO or PP was filled into the measuring cell. An SVM regression performed after the SVM classification yields the microplastic concentration of the respective sample. Further tests with varying salinity and content of organic or biological material in the water confirmed the good results. We conclude that EIS in combination with machine learning (MLEIS) seems to be a promising approach for in situ detection of microplastics and certainly warrants further research activities.

23 January 2018 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
RPRonny Peter
Ronny Peter
GFGerhard Fischerauer
Gerhard Fischerauer
The well-known cavity perturbation method, in which a cavity resonator is partially filled with a material sample is used to determine material parameters (permittivity, electrical conductivity, and permeability) at microwave frequencies. These parameters are inferred from the differences in resonant behavior between the empty cavity and the material-loaded cavity. When applying the method, one has to couple the cavity to external measuring equipment (e.g., a vector network analyzer) to obtain the S-parameters of the cavity. The insertion of a coupling device (e.g., a thin stub) detunes the cavity. If the cavity is loaded with a large sample or if one has no access to the empty cavity-both cases may occur in in-process monitoring applications-one must remove the detuning effect from measured S-parameters to produce accurate estimates of the sample material parameters. Several methods for this de-embedding have been proposed in the literature. They work well for loose or not-too strong coupling, but less so for strong coupling, which may occur in in-process monitoring situations. We have examined the known de-embedding procedures with respect to their ability for coping with strong coupling by thin stubs and propose a method that works in this case.

13 January 2020 in Measurement Science and Technology
Verified
Journal Article
Open access
PDF file
RPRonny Peter
Ronny Peter
GFGerhard Fischerauer
Gerhard Fischerauer
The microwave cavity perturbation method is widely used for material parameter measurements in connection with small homogeneous samples. Its applicability to larger and inhomogeneous samples is uncertain, but highly desirable in connection with the in- situ condition monitoring of chemical reactors. We have investigated the problem of the reconstruction of axially inhomogeneous permittivity distributions in tubular reactors from measured cavity resonance frequencies of the reactor. It is shown that the use of a priori knowledge about the function class of the permittivity distribution, which in turn follows from assumptions about the chemical process inside the reactor, allows one to reconstruct the permittivity distribution based on a few resonances only. The resulting errors in the function parameters or in the permittivity values identified are on the order of 5%, as demonstrated by analytical and numerical calculations, by numerical experiments, and by laboratory experiments.

4 December 2019 in TM - Technisches Messen
Verified
Journal Article
Closed access
PDF file
RPRonny Peter
Ronny Peter
GFGerhard Fischerauer
Gerhard Fischerauer
The spatial distribution of electrical material parameters (e. g. permittivity and conductivity) can be a valuable indicator of the state of a chemical process or the condition of the processing system. Unfortunately, there are very few measurement systems that could handle this task in the field at low cost and with small shape factors. A potential solution currently under research for the determination of material parameter distributions is based on electromagnetic resonances inside chemical reactors. In the laboratory, vector network analyzers (VNA) and personal computers are used, which is expensive. This contribution reports on an application-specific stand-alone homodyne VNA with integrated data processing as an effort to transfer the laboratory-proven method to the field. The quality of the approach, validated by comparison with commercial VNAs, is shown to suffice for typical field applications.