Josué D. Rivera-Fernández

Dr. Josué D. Rivera-Fernández

Laboratorio de Optomecatrónica, Instituto Politécnico Nacional, Mexico City, Ciudad de México, Mexico

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Macaria Hernández ChávezMacaria Hernández Chávez
Macaria Hernández Chávez
JCJosé M. Cortés-Caballero
José M. Cortés-Caballero
ÁPÁngel A. Pérez-Martínez
Ángel A. Pérez-Martínez
LHLuis Hernández-Quintanar
Luis Hernández-Quintanar
KRKaren Roa-Tort
Karen Roa-Tort
Diego Adrián Fabila BustosDiego Adrián Fabila Bustos
Diego Adrián Fabila Bustos
A Virtual Reality application was developed to be used as an immersive virtual learning strategy for Oculus Rift S Virtual Reality glasses and through Leap Motion Controller™ infrared sensors, focused on students of the Automotive Systems Engineering academic program, as a practical teaching-learning tool in the context of Education 4.0 and the pandemic caused by COVID-19 that has kept schools closed since March 2020. The technological pillars of Industry 4.0 were used to profile students so that they can meet the demands of their professional performance at the industrial level. Virtual Reality (VR) plays a very important role for the production-engineering sector in areas such as design and autonomous cars, as well as in training and driving courses. The VR application provides the student with a more immersive and interactive experience, supported by 3D models of both the main parts that make up the four-stroke combustion engine and the mechanical workshop scenario; it allows the student to manipulate the main parts of the four-stroke combustion engine through the Oculus Rift S controls and the Leap Motion Controller™ infrared sensors, and relate them to the operation of the engine, through the animation of its operation and the additional information shown for each part that makes it up in the application.

9 April 2024 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
KRKaren Roa-Tort
Karen Roa-Tort
YSYael Saavedra
Yael Saavedra
AVAngélica Villanueva-Martínez
Angélica Villanueva-Martínez
GAGanem Adriana
Ganem Adriana
LCLaura Abril Pérez Carranza
Laura Abril Pérez Carranza
JRJosué D. Rivera-Fernández
Josué D. Rivera-Fernández
Photodynamic therapy (PDT) has been based on using photosensitizers (PS) and applying light of a specific wavelength. When this technique is used for treating infections, it is known as antimicrobial photodynamic therapy (aPDT). Currently, the use of lighting sources for in vitro studies using aPDT is generally applied in multiwell cell culture plates; however, depending on the lighting arrangement, there are usually errors in the application of the technique because the light from a well can affect the neighboring wells or it may be that not all the wells are used in the same experiment. In addition, one must be awarded high irradiance values, which can cause unwanted photothermal problems in the studies. Thus, this manuscript presents an in vitro antimicrobial photodynamic therapy for a Pseudomonas aeruginosa (P. aeruginosa) and methicillin-resistant Staphylococcus aureus (MRSA) inhibition study using an arrangement of thermally isolated and independently illuminated green light source systems for eight tubes in vitro aPDT, determining the effect of the following factors: (i) irradiance level, (ii) exposure time, and (iii) Rose Bengal (RB) concentration (used as a PS), registering the Pseudomonas aeruginosa (P. aeruginosa) and methicillin-resistant Staphylococcus aureus (MRSA) inhibition rates. The results show that in the dark, RB had a poor antimicrobial rate for P. aeruginosa, finding the maximum inhibition (2.7%) at 30 min with an RB concentration of 3 µg/mL. However, by applying light in a correct dosage (time × irradiance) and the adequate RB concentration, the inhibition rate increased by over 37%. In the case of MRSA, there was no significant inhibition with RB in complete darkness and, in contrast, the rate was 100% for those experiments that were irradiated.

29 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JRJosué D. Rivera-Fernández
Josué D. Rivera-Fernández
KRKaren Roa-Tort
Karen Roa-Tort
SSSuren Stolik
Suren Stolik
AVAlma Valor
Alma Valor
Diego Adrián Fabila BustosDiego Adrián Fabila Bustos
Diego Adrián Fabila Bustos
JVJose Manuel de la Rosa Vázquez
Jose Manuel de la Rosa Vázquez
Worldwide, breast cancer is the most common type of cancer that mainly affects women. Several diagnosis techniques based on optical instrumentation and image analysis have been developed, and these are commonly used in conjunction with conventional diagnostic devices such as mammographs, ultrasound, and magnetic resonance imaging of the breast. The cost of using these instruments is increasing, and developing countries, whose deaths indices due to breast cancer are high, cannot access conventional diagnostic methods and have even less access to newer techniques. Other studies, based on the analysis of images acquired by traditional methods, require high resolutions and knowledge of the origin of the captures in order to avoid errors. For this reason, the design of a low-cost diffuse optical mammography system for biomedical image processing in breast cancer diagnosis is presented. The system combines the acquisition of breast tissue photographs, diffuse optical reflectance (as a biophotonics technique), and the processing of digital images for the study and diagnosis of breast cancer. The system was developed in the form of a medical examination table with a 638 nm red-light source, using light-emitted diode technology (LED) and a low-cost web camera for the acquisition of breast tissue images. The system is automatic, and its control, through a graphical user interface (GUI), saves costs and allows for the subsequent analysis of images using a digital image-processing algorithm. The results obtained allow for the possibility of planning in vivo measurements. In addition, the acquisition of images every 30° around the breast tissue could be used in future research in order to perform a three-dimensional (3D) reconstruction and an analysis of the captures through deep learning techniques. These could be combined with virtual, augmented, or mixed reality environments to predict the position of tumors, increase the likelihood of a correct medical diagnosis, and develop a training system for specialists. Furthermore, the system allows for the possibility to develop analysis of optical characterization for new phantom studies in breast cancer diagnosis through bioimaging techniques.

5 August 2025 in Catalysts
Verified
Journal Article
Open access
PDF file
BOBetsabé Ildefonso Ojeda
Betsabé Ildefonso Ojeda
Macaria Hernández ChávezMacaria Hernández Chávez
Macaria Hernández Chávez
MAMayra Alvarez
Mayra Alvarez
RGRosendo López González
Rosendo López González
JCJosé R. Contreras-Bárbara
José R. Contreras-Bárbara
Diego Adrián Fabila BustosDiego Adrián Fabila Bustos
Diego Adrián Fabila Bustos
The development of three types of UV radiation-based photoreactors using light-emitting diodes (LEDs) is presented. In this work, three pattern irradiation arrangements, direct radiation, internal radiation, and external radiation, were tested for deactivation of a typical model contaminant in wastewater under the same conditions. All photoreactors allow the adjustment of optical power and irradiation time and include a sensor for temperature monitoring in the solution. In this case, phenol was used as a model contaminant with TiO2 as a photocatalyst in a batch-type reactor at pH 7. The results showed that the highest degradation efficiency was achieved after 120 min, reaching 97.79% for the internal-radiation photoreactor, followed by 90.17% when the direct-radiation photoreactor was used, and 85.24% for the external-radiation photoreactor. Phenol degradation served as the basis for validating reactor performance, given its persistence and relevance as an indicator in advanced oxidation processes. It was concluded that the arrangement of LEDs in each photoreactor significantly influences phenol degradation under the same reaction conditions.

29 July 2025 in Crystals
Verified
Journal Article
Open access
PDF file
BOBetsabé Ildefonso Ojeda
Betsabé Ildefonso Ojeda
Macaria Hernández ChávezMacaria Hernández Chávez
Macaria Hernández Chávez
JCJosé R. Contreras-Bárbara
José R. Contreras-Bárbara
KRKaren Roa-Tort
Karen Roa-Tort
JRJosué D. Rivera-Fernández
Josué D. Rivera-Fernández
Diego Adrián Fabila BustosDiego Adrián Fabila Bustos
Diego Adrián Fabila Bustos
This work analyzes the performance of a photoreactor built with UV-LED technology. For this task, a UV-LED wavelength of 365 nm was used as an irradiation source, and it was electrically and spectrally characterized to ensure correct operation. To evaluate the functionality, the photoreactor was tested on the degradation of Rhodamine B (Rh B), a dye commonly used in the textile industry. The experiment was conducted under optimal conditions, using a concentration of 17 ppm of Rh B and 100 mg of zinc oxide (ZnO) as a photocatalyst in a glass reactor. The mixture was continuously stirred for 120 min, achieving 99.42% efficiency. The results showed that the UV-LED photoreactor performs well in activating ZnO for the removal of Rh B from the solution, highlighting its potential for treating textile industry wastewater. The use of LEDs offers advantages such as energy efficiency and lower environmental impact compared to traditional UV lamps. ZnO, known for its reactivity under UV light, acted as a stable photocatalyst, ensuring complete degradation of the dye without producing harmful by-products. This method provides an efficient approach to dye removal in wastewater treatment, promoting cleaner and more sustainable industrial practices.

1 February 2018
Verified
Conference Paper
Closed access
JRJosué D. Rivera-Fernández
Josué D. Rivera-Fernández
KRKaren Roa-Tort
Karen Roa-Tort
JRJose M. de la Rosa-Vazquez
Jose M. de la Rosa-Vazquez
AVAlma Valor
Alma Valor
SSSuren Stolik
Suren Stolik
GEGalileo Escobedo
Galileo Escobedo
This paper presents the implementation of an endoscopic system with an opto-mechanical revolver for the interchange of five illumination sources for the in vivo diagnostic of abnormalities in liver tissue. Also, the system allows to save images produced by light reflection or autofluorescence. A pedal was implemented to automatically interchange the illumination sources during the endoscopic procedure. Software was developed to save the images captured by the endocamera. Fatty liver images were taken in an animal model which shows the advance of the disease.