Sanam Noreen Vardag

Dr. Sanam Noreen Vardag

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2023 in Science
Verified
Journal Article
Closed access
EMEva-Marie Metz
Eva-Marie Metz
SVSanam Noreen Vardag
Sanam Noreen Vardag
SBSourish Basu
Sourish Basu
MJMartin Jung
Martin Jung
BABernhard Ahrens
Bernhard Ahrens
ABAndre Butz
Andre Butz
The Australian continent contributes substantially to the year-to-year variability of the global terrestrial carbon dioxide (CO 2 ) sink. However, the scarcity of in situ observations in remote areas prevents the deciphering of processes that force the CO 2 flux variability. In this study, by examining atmospheric CO 2 measurements from satellites in the period 2009–2018, we find recurrent end-of-dry-season CO 2 pulses over the Australian continent. These pulses largely control the year-to-year variability of Australia’s CO 2 balance. They cause two to three times larger seasonal variations compared with previous top-down inversions and bottom-up estimates. The pulses occur shortly after the onset of rainfall and are driven by enhanced soil respiration preceding photosynthetic uptake in Australia’s semiarid regions. The suggested continental-scale relevance of soil-rewetting processes has substantial implications for our understanding and modeling of global climate–carbon cycle feedbacks.

7 May 2013 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
SHS. Hammer
S. Hammer
DGD. W. T. Griffith
D. W. T. Griffith
GKG. Konrad
G. Konrad
SVSanam Noreen Vardag
Sanam Noreen Vardag
CCC. Caldow
C. Caldow
ILI. Levin
I. Levin
We thoroughly evaluate the performance of a multi-species, in situ Fourier transform infrared (FTIR) analyser with respect to high-accuracy needs for greenhouse gas monitoring networks. The in situ FTIR analyser is shown to measure CO2, CO, CH4 and N2O mole fractions continuously, all with better reproducibility than the inter-laboratory compatibility (ILC) goals, requested by the World Meteorological Organization (WMO) for the Global Atmosphere Watch (GAW) programme. Simultaneously determined δ13CO2 reaches reproducibility as good as 0.03‰. Second-order dependencies between the measured components and the thermodynamic properties of the sample, (temperature, pressure and flow rate) and the cross sensitivities among the sample constituents are investigated and quantified. We describe an improved sample delivery and control system that minimises the pressure and flow rate variations, making post-processing corrections for those quantities non-essential. Temperature disequilibrium effects resulting from the evacuation of the sample cell are quantified and improved by the usage of a faster temperature sensor. The instrument has proven to be linear for all measured components in the ambient concentration range. The temporal stability of the instrument is characterised on different time scales. Instrument drifts on a weekly time scale are only observed for CH4 (0.04 nmol mol−1 day−1) and δ13CO2 (0.02‰ day−1). Based on 10 months of continuously collected quality control measures, the long-term reproducibility of the instrument is estimated to ±0.016 μmol mol−1 CO2, ±0.03‰ δ13CO2, ±0.14 nmol mol−1 CH4, ±0.1 nmol mol−1 CO and ±0.04 nmol mol−1 N2O. We propose a calibration and quality control scheme with weekly calibrations of the instrument that is sufficient to reach WMO-GAW inter-laboratory compatibility goals.

5 May 2022 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
ALAndreas Luther
Andreas Luther
JKJulian Kostinek
Julian Kostinek
RKRalph Kleinschek
Ralph Kleinschek
SDSara Defratyka
Sara Defratyka
MSMila Stanisavljević
Mila Stanisavljević
ABAndre Butz
Andre Butz
Given its abundant coal mining activities, the Upper Silesian Coal Basin (USCB) in southern Poland is one of the largest sources of anthropogenic methane (CH4) emissions in Europe. Here, we report on CH4 emission estimates for coal mine ventilation facilities in the USCB. Our estimates are driven by pairwise upwind–downwind observations of the column-average dry-air mole fractions of CH4 (XCH4) by a network of four portable, ground-based, sun-viewing Fourier transform spectrometers of the type EM27/SUN operated during the CoMet campaign in May–June 2018. The EM27/SUN instruments were deployed in the four cardinal directions around the USCB approximately 50 km from the center of the basin. We report on six case studies for which we inferred emissions by evaluating the mismatch between the observed downwind enhancements and simulations based on trajectory calculations releasing particles out of the ventilation shafts using the Lagrangian particle dispersion model FLEXPART. The latter was driven by wind fields calculated by WRF (Weather Research and Forecasting model) under assimilation of vertical wind profile measurements of three co-deployed wind lidars. For emission estimation, we use a Phillips–Tikhonov regularization scheme with the L-curve criterion. Diagnosed by the emissions averaging kernels, we find that, depending on the catchment area of the downwind measurements, our ad hoc network can resolve individual facilities or groups of ventilation facilities but that inspecting the emissions averaging kernels is essential to detect correlated estimates. Generally, our instantaneous emission estimates range between 80 and 133 kt CH4 a−1 for the southeastern part of the USCB and between 414 and 790 kt CH4 a−1 for various larger parts of the basin, suggesting higher emissions than expected from the annual emissions reported by the E-PRTR (European Pollutant Release and Transfer Register). Uncertainties range between 23 % and 36 %, dominated by the error contribution from uncertain wind fields.

16 November 2015 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
SVSanam Noreen Vardag
Sanam Noreen Vardag
CGC. Gerbig
C. Gerbig
GJG. Janssens-Maenhout
G. Janssens-Maenhout
ILI. Levin
I. Levin
We investigate different methods for estimating anthropogenic CO2 using modeled continuous atmospheric concentrations of CO2 alone, as well as CO2 in combination with the surrogate tracers CO, δ13C(CO2) and Δ14C(CO2). These methods are applied at three hypothetical stations representing rural, urban and polluted conditions. We find that, independent of the tracer used, an observation-based estimate of continuous anthropogenic CO2 is not yet feasible at rural measurement sites due to the low signal-to-noise ratio of anthropogenic CO2 estimates at such settings. The tracers δ13C(CO2) and CO provide an accurate possibility to determine anthropogenic CO2 continuously, only if all CO2 sources in the catchment area are well characterized or calibrated with respect to their isotopic signature and CO to anthropogenic CO2 ratio. We test different calibration strategies for the mean isotopic signature and CO to CO2 ratio using precise Δ14C(CO2) measurements on monthly integrated as well as on grab samples. For δ13C(CO2), a calibration with annually averaged 14C(CO2) grab samples is most promising, since integrated sampling introduces large biases into anthropogenic CO2 estimates. For CO, these biases are smaller. The precision of continuous anthropogenic CO2 determination using δ13C(CO2) depends on measurement precision of δ13C(CO2) and CO2, while the CO method is mainly limited by the variation in natural CO sources and sinks. At present, continuous anthropogenic CO2 could be determined using the tracers δ13C(CO2) and/or CO with a precision of about 30 %, a mean bias of about 10 % and without significant diurnal discrepancies. Hypothetical future measurements of continuous Δ14C(CO2) with a precision of 5 ‰ are promising for anthropogenic CO2 determination (precision ca. 10–20 %) but are not yet available. The investigated tracer-based approaches open the door to improving, validating and reducing biases of highly resolved emission inventories using atmospheric observation and regional modeling.

20 March 2018 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
DGDavid W. T. Griffith
David W. T. Griffith
DPDenis Pöhler
Denis Pöhler
SSStefan Schmitt
Stefan Schmitt
SHSamuel Hammer
Samuel Hammer
SVSanam Noreen Vardag
Sanam Noreen Vardag
UPUlrich Platt
Ulrich Platt
In complex and urban environments, atmospheric trace gas composition is highly variable in time and space. Point measurement techniques for trace gases with in situ instruments are well established and accurate, but do not provide spatial averaging to compare against developing high-resolution atmospheric models of composition and meteorology with resolutions of the order of a kilometre. Open-path measurement techniques provide path average concentrations and spatial averaging which, if sufficiently accurate, may be better suited to assessment and interpretation with such models. Open-path Fourier transform spectroscopy (FTS) in the mid-infrared region, and differential optical absorption spectroscopy (DOAS) in the UV and visible, have been used for many years for open-path spectroscopic measurements of selected species in both clean air and in polluted environments. Near infrared instrumentation allows measurements over longer paths than mid-infrared FTS for species such as greenhouse gases which are not easily accessible to DOAS. In this pilot study we present the first open-path near-infrared (4000–10 000 cm−1, 1.0–2.5 µm) FTS measurements of CO2, CH4, O2, H2O and HDO over a 1.5 km path in urban Heidelberg, Germany. We describe the construction of the open-path FTS system, the analysis of the collected spectra, several measures of precision and accuracy of the measurements, and the results a four-month trial measurement period in July–November 2014. The open-path measurements are compared to calibrated in situ measurements made at one end of the open path. We observe significant differences of the order of a few ppm for CO2 and a few tens of ppb for CH4 between the open-path and point measurements which are 2 to 4 times the measurement repeatability, but we cannot unequivocally assign the differences to specific local sources or sinks. We conclude that open-path FTS may provide a valuable new tool for investigations of atmospheric trace gas composition in complex, small-scale environments such as cities.

21 August 2014 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
SVSanam Noreen Vardag
Sanam Noreen Vardag
SHS. Hammer
S. Hammer
SOSimon O'Doherty
Simon O'Doherty
TST. G. Spain
T. G. Spain
BWB. Wastine
B. Wastine
ILI. Levin
I. Levin
A 2-month measurement campaign with a Fourier transform infrared analyser as a travelling comparison instrument (TCI) was performed at the Advanced Global Atmospheric Gases Experiment (AGAGE) and World Meteorological Organization (WMO) Global Atmosphere Watch (GAW) station at Mace Head, Ireland. The aim was to evaluate the compatibility of atmospheric methane (CH4), carbon dioxide (CO2) and nitrous oxide (N2O) measurements of the routine station instrumentation, consisting of a gas chromatograph (GC) for CH4 and N2O as well as a cavity ring-down spectroscopy (CRDS) system for CH4 and CO2. The advantage of a TCI approach for quality control is that the comparison covers the entire ambient air measurement system, including the sample intake system and the data evaluation process. For initial quality and performance control, the TCI was run in parallel with the Heidelberg GC before and after the measurement campaign at Mace Head. Median differences between the Heidelberg GC and the TCI were well within the WMO inter-laboratory compatibility target for all three greenhouse gases. At Mace Head, the median difference between the station GC and the TCI were −0.04 nmol mol−1 for CH4 and −0.37 nmol mol−1 for N2O (GC-TCI). For N2O, a similar difference (−0.40 nmol mol−1) was found when measuring surveillance or working gas cylinders with both instruments. This suggests that the difference observed in ambient air originates from a calibration offset that could partly be due to a difference between the WMO N2O X2006a reference scale used for the TCI and the Scripps Institution of Oceanography (SIO-1998) scale used at Mace Head and in the whole AGAGE network. Median differences between the CRDS G1301 and the TCI at Mace Head were 0.12 nmol mol−1 for CH4 and 0.14 μmol mol−1 for CO2 (CRDS G1301 – TCI). The difference between both instruments for CO2 could not be explained, as direct measurements of calibration gases show no such difference. The CH4 differences between the TCI, the GC and the CRDS G1301 at Mace Head are much smaller than the WMO inter-laboratory compatibility target, while this is not the case for CO2 and N2O.