Javier Salgado Fernández

Mr. Javier Salgado Fernández

Dto. de Expresión Gráfica, Diseño y Proyectos, University of Malaga, Málaga, Andalusia, Spain
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MTManuel Trinidad-Fernández
Manuel Trinidad-Fernández
BBBenoît Bossavit
Benoît Bossavit
Javier Salgado FernándezJavier Salgado Fernández
Javier Salgado Fernández
SASusana Abbate-Chica
Susana Abbate-Chica
AFAntonio J. Fernández-leiva
Antonio J. Fernández-leiva
Antonio Cuesta-VargasAntonio Cuesta-Vargas
Antonio Cuesta-Vargas
Neck disorders have a significant impact on people because of their high incidence. The head-mounted display (HMD) systems, such as Meta Quest 2, grant access to immersive virtual reality (iRV) experiences. This study aims to validate the Meta Quest 2 HMD system as an alternative for screening neck movement in healthy people. The device provides data about the position and orientation of the head and, thus, the neck mobility around the three anatomical axes. The authors develop a VR application that solicits participants to perform six neck movements (rotation, flexion, and lateralization on both sides), which allows the collection of corresponding angles. An InertiaCube3 inertial measurement unit (IMU) is also attached to the HMD to compare the criterion to a standard. The mean absolute error (MAE), the percentage of error (%MAE), and the criterion validity and agreement are calculated. The study shows that the average absolute errors do not exceed 1° (average = 0.48 ± 0.09°). The rotational movement’s average %MAE is 1.61 ± 0.82%. The head orientations obtain a correlation between 0.70 and 0.96. The Bland–Altman study reveals good agreement between the HMD and IMU systems. Overall, the study shows that the angles provided by the Meta Quest 2 HMD system are valid to calculate the rotational angles of the neck in each of the three axes. The obtained results demonstrate an acceptable error percentage and a very minimal absolute error when measuring the degrees of neck rotation; therefore, the sensor can be used for screening neck disorders in healthy people.

1 November 2020 in ICERI Proceedings
Verified
Conference Paper
Closed access
PDF file
Javier Salgado FernándezJavier Salgado Fernández
Javier Salgado Fernández
JMJose L. Martínez
Jose L. Martínez
FSFrancisco Soto
Francisco Soto
FOFrancisco Ortiz
Francisco Ortiz
Information about the paper titled "COOPERATIVE VIRTUAL REALITY PROPOSAL FOR ENGINEERING TRAINING AND EDUCATION" at IATED Digital Library

9 December 2021
Verified
Book Chapter
Closed access
PDF file
Javier Salgado FernándezJavier Salgado Fernández
Javier Salgado Fernández
FLFrancisco José Soto Lara
Francisco José Soto Lara
MMManuel Damian Marin
Manuel Damian Marin

1 November 2020 in ICERI Proceedings
Verified
Conference Paper
Closed access
PDF file
JGJorge Pérez García
Jorge Pérez García
JTJosé Luis Martínez Torres
José Luis Martínez Torres
ENEnrique Navarrete
Enrique Navarrete
Javier Salgado FernándezJavier Salgado Fernández
Javier Salgado Fernández
Information about the paper titled "PARAMETERIZATION IN CAD ENVIRONMENT TO PROMOTE THE LEARNING OF GRAPHIC EXPRESSION IN A COLLABORATIVE WAY IN INDUSTRIAL ENGINEERING STUDENTS (ELECTRICAL). INCLUSION IN COVID-19 SCENARIO" at IATED Digital Library