Francisco Javier Soto Lara

Francisco Javier Soto Lara

Auto-generated profile, based on publicly available information

Francisco Javier Soto Lara

Universidad de Málaga (Spain)

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2021
Verified
Book Chapter
Closed access
PDF file
Javier Salgado FernándezJavier Salgado Fernández
Javier Salgado Fernández
FLFrancisco José Soto Lara
Francisco José Soto Lara
MMManuel Damian Marin
Manuel Damian Marin

1 January 2022 in DYNA Energia y Sostenibilidad
Verified
Journal Article
Closed access
JSJuan Franquelo Soler
Juan Franquelo Soler
EBElidia Beatriz Blázquez
Elidia Beatriz Blázquez
OMOscar DE Cozar Macias
Oscar DE Cozar Macias
MMManuel Damian Marin
Manuel Damian Marin
FVFrancisco Javier Soto Villaran
Francisco Javier Soto Villaran
Natural ventilation has become one of the most effective and sustainable strategies to address COVID-19 in confined spaces. Air intake through windows and other openings improves the Indoor Air Quality (IAQ) of a classroom, decreases the likelihood of respiratory disease transmission with an adequate social distance of about 1.5 m and is affordable in terms of energy consumption. In this study, a comparison of CO2 concentration, wind speed, number of people, type of ventilation and window surfaces of a school in a Mediterranean climate is carried out for 4 different cases of opening. For this purpose, CO2 levels were measured in different classrooms with different window openings (33%, 67%, 81%, 81%). (33%, 67%, 81% and 100% respectively). In addition, three types of ventilation (cross ventilation, partial cross ventilation and multidirectional ventilation) were analyzed in a time period between February and March 2021. The results show an interaction between CO2 levels and the type of ventilation. Thus, the fact that the window surface is a critical factor in reducing CO2 concentrations was determined, considering that the distance between students was approximately 1.5 m. Therefore, the orientation of buildings towards the predominant wind direction and the Window to Floor Ratio (WFR) should be reconsidered in new constructions. Keywords: natural ventilation, indoor air quality, carbon dioxide (CO2) concentration, school, WFR.

6 July 2023 in American Journal of Infection Control
Verified
Journal Article
Open access
JAJose Aguilera arjona
Jose Aguilera arjona
EGEnrique Navarrete-De Gálvez
Enrique Navarrete-De Gálvez
AHAli El Houssaini
Ali El Houssaini
FSFrancisco Soto-Lara
Francisco Soto-Lara
EHEnrique Herrera-Ceballos
Enrique Herrera-Ceballos
MGMaría V. de Gálvez
María V. de Gálvez
Background: To analyze whether the application of topical formulas as cosmetics or sunscreens could affect the skin thermographic readings in terms of infection control in pandemic situations. Methods: The temperature of the skin of the dorsal region of the back and the face of 20 volunteers was followed after the application of 6 different types of gels, sunscreens, and make-up under controlled temperature and humidity conditions. High -resolution thermographic images were analyzed to calculate the temperature of treated skin compared to skin free of topical products. Results: The application of hydroalcoholic gel resulted in a mean drop of more than 2 degrees C just after 1 minute followed by organic sunscreens until 1.7 degrees C. Recovery was observed progressively until minute 9. Color make- up type formulas, rich in iron oxide as well as sunscreens with mineral filters had little or no effect on the skin thermal response. Conclusions: It is possible to alter the skin temperature almost immediately by using hydroalcoholic gels and sunscreen cosmetics. So, it is possible to produce false negative data in the readings of patients screened thermically. (c) 2023 The Author(s). Published by Elsevier Inc. on behalf of Association for Professionals in Infection Control and Epidemiology, Inc. This is an open access article under the CC BY -NC -ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

1 July 2022 in DYNA Ingenieria e Industria
Verified
Journal Article
Closed access
JSJuan Franquelo Soler
Juan Franquelo Soler
EBElidia Beatriz Blázquez
Elidia Beatriz Blázquez
OMOscar DE Cozar Macias
Oscar DE Cozar Macias
MMManuel Damian Marin
Manuel Damian Marin
FLFrancisco Javier Soto Lara
Francisco Javier Soto Lara
Natural ventilation is one of the most suitable and sustainable means against COVID-19 in confined spaces, where social distancing reduces the possible cross transmission of the virus between humans.

1 May 2024 in DYNA Ingenieria e Industria
Verified
Journal Article
Closed access
JSJuan Franquelo Soler
Juan Franquelo Soler
FLFrancisco Javier Soto Lara
Francisco Javier Soto Lara
EBElidia Beatriz Blázquez
Elidia Beatriz Blázquez
OMOscar DE Cozar Macias
Oscar DE Cozar Macias
MMManuel Damian Marin
Manuel Damian Marin
La ventilación natural cruzada es considerada una estrategia efectiva y sostenible frente a pandemias respiratorias en espacios confinados. La entrada de aire en un aula, a través de puertas y ventanas, mejora la calidad del aire interior (Indoor Air Quality - IAQ), disminuye la transmisión de enfermedades respiratorias con una distancia social adecuada (1.5 m), siendo accesible en términos de consumo energético. En este estudio se realiza una comparación entre tipos de ventilación cruzada, a partir de la concentración de CO2, número de personas y superficies de ventilación de ventanas y puertas de un centro universitario en un clima mediterráneo. Se midieron los niveles de CO2 en dos aulas similares y anexas, con diferentes aperturas de ventanas y puertas (0%, 33% y 66%) con 2 secuencias de carga y descarga. Se analizaron dos tipos de ventilación cruzada: ventilación cruzada con ventana y puerta en la misma dirección o directa (CDIR), y ventilación cruzada en diagonal (CDIA), en un período de tiempo de 3 h. en diciembre de 2022. Los resultados muestran una interacción entre los niveles de CO2 y el tipo de ventilación. La ventilación cruzada diagonal fue más efectiva en términos de renovaciones de aire (ACH) que la directa, en rangos de apertura menores (33%), siendo la ventilación cruzada directa más efectiva globalmente y en rangos de apertura mayores (66%), en las condiciones de este estudio de caso.

1 January 2022 in DYNA Energia y Sostenibilidad
Verified
Journal Article
Closed access
JSJuan Franquelo Soler
Juan Franquelo Soler
EBElidia Beatriz Blázquez
Elidia Beatriz Blázquez
OMOscar DE Cozar Macias
Oscar DE Cozar Macias
MMManuel Damian Marin
Manuel Damian Marin
FVFrancisco Javier Soto Villaran
Francisco Javier Soto Villaran
In 1979, the Spanish government implemented the standard “Basic Building on Thermal Conditions in Buildings NBE-CT-79”. It was then that the first requirements regarding insulation and thermal properties of materials were established to reduce energy consumption. The Mediterranean climate has influenced that insufficient attention has been paid to building insulation. In dwellings before 1979, it was detected that there is a feeling of lack of comfort. However, it is not so well known that there is a lack of airtightness in these dwellings, which may contribute to discomfort. The aim of the article is to find out if the air that enters spontaneously by infiltration produces effects similar to those of a displacement diffuser and how it affects thermal comfort. Thus, cold air would flow down the walls and be evenly distributed on the floor in winter, creating a homogeneous layer and feeling discomfort. Air infiltration measurements were carried out in 5 dwellings with an anemometer and infrared thermography to support the initial hypothesis. The Fanger Method, provided by the Polytechnic University of Valencia, was used to determine the thermal sensation produced. It was found that the cold air descended slowly and continuously to the ground in a similar way to a displacement diffuser, remaining for hours and being influential in the thermal conditions of the rooms and the lack of comfort of its occupants. Keywords: air infiltration, discomfort, thermography, displacement difusión, energy efficiency.