The efficacy of linac-based SRS/fSRS treatments using the single-isocenter coplanar FFF-VMAT technique for both single and multiple BM was investigated. Seventy patients (129 BM) treated with 15–21 Gy in 1 (n = 59) or 27 Gy in 3 (n = 11) fractions were analyzed. For each fraction, plans involving the intra-fractional errors measured by post-treatment CBCT were recalculated. The relationships of BM size, distance-to-isocenter, and barycenter shift with the difference in target coverage were evaluated. Clinical outcomes were assessed using logistic regression and Kaplan-Meier analysis. The median delivery time was 3.78 min (range, 1.83–9.25). The median post-treatment 3D error was 0.5 mm (range, 0.1–2.7) and the maximum rotational error was 0.3° (range, 0.0–1.3). In single BM patients, the GTV D95% was never reduced by >5%, whereas PTV D95% reductions >1% occurred in only 11 cases (29%). In multiple BM patients, dose deficits >5% and >1% occurred in 2 GTV (2%) and 34 PTV (37%), respectively. The differences in target coverage showed a moderate-to-strong correlation only with barycenter shift. Local failure of at least one treated BM occurred in 13 (21%) patients and the 1-year and 2-year local control rates for all lesions were 94% and 90%, respectively. The implemented workflow ensured that the degradation of target and brain dose metrics in delivered treatments was negligible. Along with encouraging clinical outcomes, these findings warrant a reduction in the PTV margins at our institution.
Background: Radiotherapy is essential in the management of head–neck cancer. During the course of radiotherapy, patients may develop significant anatomical changes. Re-planning with adaptive radiotherapy may ensure adequate dose coverage and sparing of organs at risk. We investigated the consequences of adaptive radiotherapy on head–neck cancer patients treated with volumetric-modulated arc radiation therapy compared to simulated non-adaptive plans: Materials and methods: We included in this retrospective dosimetric analysis 56 patients treated with adaptive radiotherapy. The primary aim of the study was to analyze the dosimetric differences with and without an adaptive approach for targets and organs at risk, particularly the spinal cord, parotid glands, oral cavity and larynx. The original plan (OPLAN) was compared to the adaptive plan (APLAN) and to a simulated non-adaptive dosimetric plan (DPLAN). Results: The non-adaptive DPLAN, when compared to OPLAN, showed an increased dose to all organs at risk. Spinal cord D2 increased from 27.91 (21.06–31.76) Gy to 31.39 (27.66–38.79) Gy (p = 0.00). V15, V30 and V45 of the DPLAN vs. the OPLAN increased by 20.6% (p = 0.00), 14.78% (p = 0.00) and 15.55% (p = 0.00) for right parotid; and 16.25% (p = 0.00), 18.7% (p = 0.00) and 20.19% (p = 0.00) for left parotid. A difference of 36.95% was observed in the oral cavity V40 (p = 0.00). Dose coverage was significantly reduced for both CTV (97.90% vs. 99.96%; p = 0.00) and PTV (94.70% vs. 98.72%; p = 0.00). The APLAN compared to the OPLAN had similar values for all organs at risk. Conclusions: The adaptive strategy with re-planning is able to avoid an increase in dose to organs at risk and better target coverage in head–neck cancer patients, with potential benefits in terms of side effects and disease control.