This paper presents a combination of two techniques for high-resolution ultrasonic distance measurements in air. The first is the cross correlation between transmitted and received signals to determine the time of flight (TOF), and the second is sine fitting of other transmitted and received signals to determine the phase shift (PS) between them. Sine fitting can estimate the PS with very high accuracy. The result of this synergy is a very accurate distance measurement. For example, the final uncertainty is less than 100 for distances up to 1200 mm.
This experimental study provides a characterization of the flow field created by bed discordance at a fixed 70 open-channel confluence on the basis of detailed free surface topography and three-component acoustic Doppler velocimetry measurements, which are contrasted with the results for a concordant bed junction. Due to bed discordance, the jet-like flow from the tributary is bent downstream to be aligned with the main channel axis. Underneath the tributary backward-facing step, separation occurs, producing negative vorticity along the main channel axis. A strong secondary motion downstream of the tributary junction is related to flow separation at the step and to flow release from the jet-like flow induced by a difference in the curvature of jet-like motion. A quantification of the terms in the equation of conservation of the longitudinal vorticity shows that the vortex stretching terms are sufficient to explain the development of the helical motion, which is thus classified as a secondary motion of Prandtl's first kind.
This paper is concerned with the characterization of depth profiles defects in metallic structures. Experimental work using giant magnetoresistors (GMR) scanning automatically a metallic plate with eddy currents induced by an excitation coil has been carried out and is described. The results are analyzed in comparison with the simulation results obtained with a commercial finite element model for some test cases.
18 December 2009 in IEEE Transactions on Instrumentation and Measurement
In this paper, the bias on the estimated amplitude, which is caused by Gaussian jitter, is studied in case of the IEEE 1057 standard three-parameter sine-fitting method. Because no analytical study exists, this source of uncertainty is usually not considered. Nowadays, it is becoming more and more important due to the ever increasing sampling rates available in analog-to-digital converters (ADCs), which are used in innumerable application like high-speed digital oscilloscopes. The effect of additive noise is also taken into account.
18 March 2010 in IEEE Transactions on Instrumentation and Measurement
In this paper, a new processing scheme for compensating the liftoff effect is proposed to increase the signal-to-noise ratio of measurements carried out when a duralumin plate with artificially manufactured defects was scanned with eddy-current probes. The mathematical algorithm is based on the spatial frequency behavior of the output signals with the liftoff distance (the distance between the probe used for inspection and the sample) and its equivalent form (deconvolution) in the spatial domain. Results are presented for measurements performed at three different distances for the same defect of the duralumin plate.