Dr. Med. Guram Imnadze

Dr. Dr. Med. Guram Imnadze

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2022 in EP Europace
Verified
Journal Article
Open access
PDF file
MHMustapha El Hamriti
Mustapha El Hamriti
MBMartin Braun
Martin Braun
SMStephan Molatta
Stephan Molatta
DIDr. Med. Guram Imnadze
Dr. Med. Guram Imnadze
MKMoneeb Khalaph
Moneeb Khalaph
PSPhilipp Sommer
Philipp Sommer
Accessory pathway (AP) ablation is a standard procedure for the treatment of Wolff-Parkinson-White syndrome (WPW). Twelve-lead electrocardiogram (ECG)-based delta wave analysis is essential for predicting ablation sites. Previous algorithms have shown to be complex, time-consuming, and unprecise. We aimed to retrospectively develop and prospectively validate a new, simple ECG-based algorithm considering the patients’ heart axis allowing for exact localization of APs in patients undergoing ablation for WPW. Our multicentre study included 211 patients undergoing ablation of a single manifest AP due to WPW between 2013 and 2021. The algorithm was developed retrospectively and validated prospectively by comparing its efficacy to two established ones (Pambrun and Arruda). All patients (32 ± 19 years old, 47% female) underwent successful pathway ablation. Prediction of AP-localization was correct in 197 patients (93%) (sensitivity 92%, specificity 99%, PPV 96%, and NPV 99%). Our algorithm was particularly useful in correctly localizing antero-septal/-lateral (sensitivity and specificity 100%) and posteroseptal (sensitivity 98%, specificity 92%) AP in proximity to the tricuspid valve. The accuracy of EASY-WPW was superior compared to the Pambrun (93% vs. 84%, P = 0.003*) and the Arruda algorithm (94% vs. 75%, P < 0.001*). A subgroup analysis of children (n = 58, 12 ± 4 years old, 55% female) revealed superiority to the Arruda algorithm (P < 0.001*). The reproducibility of our algorithm was excellent (ϰ>0.8; P < 0.001*). The novel EASY-WPW algorithm provides reliable and accurate pre-interventional ablation site determination in WPW patients. Only two steps are necessary to locate left-sided AP, and three steps to determine right-sided AP.

27 September 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
PFPiotr Futyma
Piotr Futyma
ASArian Sultan
Arian Sultan
ŁZŁukasz Piotr Zarębski
Łukasz Piotr Zarębski
DIDr. Med. Guram Imnadze
Dr. Med. Guram Imnadze
VMVera Maslova
Vera Maslova
JCJulian K R Chun
Julian K R Chun
Advanced ablation strategies are needed to treat ventricular tachycardia (VT) and premature ventricular complexes (PVC) refractory to standard unipolar radiofrequency ablation (Uni-RFA). Bipolar radiofrequency catheter ablation (Bi-RFA) has emerged as a treatment option for refractory VT and PVC. Multicentre registry data on the use of Bi-RFA in the setting of refractory VT and PVC are lacking. The aim of this Bi-RFA registry is to determine its real-world safety, feasibility, and efficacy in patients with refractory VT/PVC. Consecutive patients undergoing Bi-RFA at 16 European centres for recurring VT/PVC after at least one standard Uni-RFA were included. Second ablation catheter was used instead of a dispersive patch and was positioned at the opposite site of the ablation target. Between March 2021 and August 2024, 91 patients underwent 94 Bi-RFA procedures (74 males, age 62 ± 13, and prior Uni-RFA range 1–8). Indications were recurrence of PVC (n = 56), VT (n = 20), electrical storm (n = 13), or PVC-triggered ventricular fibrillation (n = 2). Procedural time was 160 ± 73 min, Bi-RFA time 426 ± 286 s, and mean Uni-RFA time 819 ± 697 s. Elimination of clinical VT/PVC was achieved in 67 (74%) patients and suppression of VT/PVC in a further 10 (11%) patients. In the remaining 14 patients (15%), no effect on VT/PVC was observed. Three major complications occurred: coronary artery occlusion, atrioventricular block, and arteriovenous fistula. Follow-up lasted 7 ± 8 months. Nineteen patients (61%) remained VT free. ≥80% PVC burden reduction was achieved in 45 (78%). These real-world registry data indicate that Bi-RFA appears safe, is feasible, and is effective in the majority of patients with VT/PVC.

23 February 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
VSVanessa Sciacca
Vanessa Sciacca
TFThomas Fink
Thomas Fink
HKHermann Körperich
Hermann Körperich
LBLeonard Bergau
Leonard Bergau
DGDenise Guckel
Denise Guckel
CSChristian Sohns
Christian Sohns
Atrial fibrillation (AF) ablation protocols using energy delivery with very high power and short duration (vHPSD) have been introduced to improve lesion formation. This study reports procedural data of vHPSD ablation in AF patients and analyses characteristics of ablation-induced left atrial (LA) scar formation from cardiac magnetic resonance imaging (MRI). Sixty consecutive patients undergoing index pulmonary vein isolation following our institutional Q4U-AF workflow were prospectively enrolled. Ablation was conducted using a contact force sensing catheter allowing for vHPSD ablation using a temperature-controlled ablation mode. Thirty patients underwent cardiac late gadolinium enhancement MRI of the LA 3 months after ablation to assess LA scar. Mean procedural duration was 66.5 ± 14.8 min. Mean ablation time was 4.7 ± 0.9 min with a mean number of 69.9 ± 14.2 applications. First-pass isolation was achieved in 51 patients (85%) for the right pulmonary veins (RPVs), in 37 patients (61.7%) for the left pulmonary veins (LPVs), and in 34 patients (56.7%) for both pulmonary veins (PVs). Magnetic resonance imaging at 3 months post-ablation demonstrated a mean scar width of 14.4 ± 2.6 mm around RPVs and 11.9 ± 1.9 mm at LPVs (P > 0.05). Complete PV encirclement was observed in 76.7% for RPVs, in 76.7% for LPVs, and in 66.7% for both PV pairs. During a mean follow-up of 4.7 ± 1.4 months, arrhythmia recurrence was observed in 3.3% of the patients. Pulmonary vein isolation following a novel vHPSD workflow resulted in short procedure duration and high acute and mid-term efficacy. Magnetic resonance imaging demonstrated durable and transmural PV lesions with homogeneous and contiguous scar formation.

22 October 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DGDenise Guckel
Denise Guckel
KIKhuraman Isgandarova
Khuraman Isgandarova
LBLeonard Bergau
Leonard Bergau
Misagh PiranMisagh Piran
Misagh Piran
MHMustapha El Hamriti
Mustapha El Hamriti
CSChristian Sohns
Christian Sohns
Diabetes mellitus (DM) plays a crucial role in the regulation of atrial fibrillation (AF). This study aimed to evaluate the outcome of pulmonary vein isolation (PVI) using a single-shot device in patients with AF and DM. A total of 531 consecutive patients undergoing initial cryoballoon (CB)-guided PVI were evaluated. Two hundred eighty-one patients (53%) suffered from paroxysmal AF (PAF; mean age 51 ± 23.2 years, 26% female), 250 patients (48%) from persistent AF (PERS; 64 ± 10.0 years old, 30% female) and 80 patients (15%) were diagnosed with coincidental DM (68 ± 19.6 years old, 30% female). Follow-up visits were performed at 3, 6 and 12 months including 7-day Holter ECGs. Primary endpoint was the first documented recurrence of atrial tachyarrhythmia. AF recurrence occurred in 26% (140 patients). PAF patients with DM presented with a significantly higher risk for arrhythmia recurrence (Kaplan Meier analysis; Log rank p < 0.001 *). Multivariate analyses found DM to be an independent predictor (IP) for AF recurrence (p = 0.009 *, hazard ratio (HR) 4.363, confidence interval (CI) 1.456–13.074). In PERS, DM was associated with a 43% increase in AF recurrence (p = 0.320, HR 1.427, CI 0.707–2.879). DM has relevant effects on AF recurrence after PVI-only ablation approaches for AF. Major differences were observed in PAF as DM seems to favor the development of individual arrhythmia substrate, which is usually not yet present in PAF. In PERS, DM effects are less pronounced as individual fibrosis has already developed. Thus, personalized paths addressing individual arrhythmia substrates are needed in this specific cohort of patients.

30 September 2022 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
VSVanessa Sciacca
Vanessa Sciacca
TFThomas Fink
Thomas Fink
DGDenise Guckel
Denise Guckel
MHMustapha El Hamriti
Mustapha El Hamriti
MKMoneeb Khalaph
Moneeb Khalaph
DIDr. Med. Guram Imnadze
Dr. Med. Guram Imnadze
Background: Ventricular fibrillation (VF) is a leading cause of cardiovascular death worldwide. However, recurrence rates of arrhythmia are high leading to mortality and morbidity. Recently, Purkinje fibers have been identified as potential sources of VF initiation and maintenance.Aim: The study analyzes the feasibility and effectiveness of catheter ablation in patients with recurrent VF by specific Purkinje de-networking (PDN).Methods: Consecutive patients with recurrent VF undergoing PDN were included in this observational study. The procedural endpoint was the non-inducibility of sustained ventricular arrhythmia. A three-dimensional -anatomical mapping was conducted, and the specific cardiac conduction system and Purkinje fibers were tagged. All detectable Purkinje signals were ablated in the left ventricle (LV). Additional right ventricular (RV) PDN was performed in case of VF inducibility after LV ablation. Follow-up was performed by patient visits at our outpatient clinic including device interrogation and by telephone interviews.Results: Eight patients were included in the study. Six patients were females (75%); the median age during the procedure was 43 [37;57] years and the median body mass index was 24 [23;33] kg/m2. Four patients (50%) had known structural heart disease with two cases of ischemic cardiomyopathy and two cases of dilated cardiomyopathy. In four patients (50%), no underlying structural heart disease could be identified. The median LV ejection fraction was 42 ± 16.4%. All patients had an implantable cardioverter-defibrillator (ICD) prior to ablation with documentation of recurrent VF. The median number of ICD shocks before the ablation was 5 [3;7]. LV PDN was performed in all patients. In two patients (25%), an additional RV PDN was performed. Non-inducibility of any ventricular arrhythmia was achieved in all patients after PDN. Two patients showed complete left bundle branch block post-ablation. The median follow-up duration was 264 [58;421] days. Two patients (25%) experienced ventricular arrhythmia recurrence with recurrent ICD-shock delivery. One patient died during follow-up with an unknown cause of death. Six patients (75%) experienced no arrhythmia recurrence during follow-up.Conclusion: Purkinje de-networking represents a novel treatment option for patients with recurrent VF without arrhythmia substrate or specific arrhythmia triggers with promising results in terms of efficiency and feasibility. Larger and more prospective studies are needed for a systematic evaluation.

19 August 2019 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Open access
PDF file
DIDr. Med. Guram Imnadze
Dr. Med. Guram Imnadze
TZThomas Zerm
Thomas Zerm
Introduction: Sudden cardiac death from ventricular fibrillation (VF) remains a major health problem worldwide. Currently, there are limited treatment options available to patients who suffer from episodes of VF. Because Purkinje fibers have been implicated as a source of initiation of VF, we are presenting the first paper of a series highlighting the promising results of substrate modulation through “De‐Networking” of the Purkinje system preventing VF in patients without an alternative ablation strategy.Methods and Results: We studied 10 consecutive patients (two female) all but one implanted with an ICD with documented VF or fast polymorphic Ventricular tachycardia (VT) (five patients without history of structural heart disease, two with ischemic cardiomyopathy, one with hypertrophic obstructive cardiomyopathy, one with dilated cardiomyopathy, and one with aortic valve disease). After 3D electroanatomical mapping, the left bundle branch (LBB) and left ventricular Purkinje potentials were annotated creating a virtual triangle with the apex formed by the distal LBB and the base by the most distal Purkinje potentials. Linear radiofrequency catheter ablation at the base of the triangle was performed, followed by ablation within the virtual triangle sparing the LBB and both fascicles (“de‐networking”). All patients were treated without complications. During 1‐year follow‐up, only 2/10(20%) patients experienced recurrence in form of a single episode of polymorphic VT/VF.Conclusion: Catheter ablation of VF through “de‐networking” of the Purkinje system in patients without overt arrhythmia substrate or trigger appears safe and effective and will require further study in a larger patient cohort.