Vanessa Sciacca

Dr. Vanessa Sciacca

Herz- und Diabeteszentrum, Bad Oeynhausen, North Rhine-Westphalia, Germany
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LBLeonard Bergau
Leonard Bergau
PBPhilipp Bengel
Philipp Bengel
VSVanessa Sciacca
Vanessa Sciacca
TFThomas Fink
Thomas Fink
CSChristian Sohns
Christian Sohns
PSPhilipp Sommer
Philipp Sommer
Atrial fibrillation (AF) is the most common sustained arrhythmia worldwide and has a strong association with heart failure (HF). It often remains unclear if HF is the cause or consequence of AF due to the complexity of the processes that are involved in both the perpetuation of AF and the development of HF. To date, two therapeutic strategies are accepted as the standard of care in AF patients with heart failure. Rhythm control aims to permanently restore sinus rhythm, whereas a rate-control strategy aims to slow ventricular rate without the termination of AF. In the last 5 years a tremendous number of important studies have been published investigating the optimal therapeutic strategy in HF patients. This review highlights the important studies with respect to the involvement of AF in promoting left-ventricular dysfunction and discusses the optimal strategy in HF patients suffering from AF.

20 October 2023 in Balkan Medical Journal
Verified
Journal Article
Open access
VNVinitha Nesapiragasan
Vinitha Nesapiragasan
MHMert İlker Hayıroğlu
Mert İlker Hayıroğlu
VSVanessa Sciacca
Vanessa Sciacca
PSPhilipp Sommer
Philipp Sommer
CSChristian Sohns
Christian Sohns
TFThomas Fink
Thomas Fink
Catheter ablation has emerged as an effective treatment for atrial arrhythmias, and pulmonary vein isolation (PVI) is the cornerstone of ablation strategies. Significant technological evolution and widespread increase in operator experience have facilitated the effectiveness of catheter ablation to achieve durable PVIs in single or multiple ablation procedures. Nevertheless, arrhythmia recurrence is a common problem even after establishing PVI. Data on catheter ablation in these patients are sparse and repeat ablation in this population is highly challenging. In this review we have summarized the available data as well as potential strategies of catheter ablation following the initial PVI.

22 April 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
RTRoland Richard Tilz
Roland Richard Tilz
MFMarcel Feher
Marcel Feher
JVJulia Vogler
Julia Vogler
KBKerstin Bode
Kerstin Bode
ADAlexandru Ionut Duta
Alexandru Ionut Duta
SPSorin Stefan Popescu
Sorin Stefan Popescu
Aims: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients’ comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. Methods and results: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. Conclusion: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.

4 July 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
PSPhilipp Sommer
Philipp Sommer
VSVanessa Sciacca
Vanessa Sciacca
Matteo AnselminoMatteo Anselmino
Matteo Anselmino
RTRoland Richard Tilz
Roland Richard Tilz
FBFelix Bourier
Felix Bourier
ABAlan Bulava
Alan Bulava
Interventional electrophysiology offers a great variety of treatment options to patients suffering from symptomatic cardiac arrhythmia. Catheter ablation of supraventricular and ventricular tachycardia has globally evolved a cornerstone in modern arrhythmia management. Complex interventional electrophysiological procedures engaging multiple ablation tools have been developed over the past decades. Fluoroscopy enabled interventional electrophysiologist throughout the years to gain profound knowledge on intracardiac anatomy and catheter movement inside the cardiac cavities and hence develop specific ablation approaches. However, the application of X-ray technologies imposes serious health risks to patients and operators. To reduce the use of fluoroscopy during interventional electrophysiological procedures to the possibly lowest degree and to establish an optimal protection of patients and operators in cases of fluoroscopy is the main goal of modern radiation management. The present manuscript gives an overview of possible strategies of fluoroscopy reduction and specific radiation protection strategies.

12 December 2022 in EP Europace
Verified
Journal Article
Open access
PDF file
MHMustapha El Hamriti
Mustapha El Hamriti
MBMartin Braun
Martin Braun
SMStephan Molatta
Stephan Molatta
DIDr. Med. Guram Imnadze
Dr. Med. Guram Imnadze
MKMoneeb Khalaph
Moneeb Khalaph
PSPhilipp Sommer
Philipp Sommer
Accessory pathway (AP) ablation is a standard procedure for the treatment of Wolff-Parkinson-White syndrome (WPW). Twelve-lead electrocardiogram (ECG)-based delta wave analysis is essential for predicting ablation sites. Previous algorithms have shown to be complex, time-consuming, and unprecise. We aimed to retrospectively develop and prospectively validate a new, simple ECG-based algorithm considering the patients’ heart axis allowing for exact localization of APs in patients undergoing ablation for WPW. Our multicentre study included 211 patients undergoing ablation of a single manifest AP due to WPW between 2013 and 2021. The algorithm was developed retrospectively and validated prospectively by comparing its efficacy to two established ones (Pambrun and Arruda). All patients (32 ± 19 years old, 47% female) underwent successful pathway ablation. Prediction of AP-localization was correct in 197 patients (93%) (sensitivity 92%, specificity 99%, PPV 96%, and NPV 99%). Our algorithm was particularly useful in correctly localizing antero-septal/-lateral (sensitivity and specificity 100%) and posteroseptal (sensitivity 98%, specificity 92%) AP in proximity to the tricuspid valve. The accuracy of EASY-WPW was superior compared to the Pambrun (93% vs. 84%, P = 0.003*) and the Arruda algorithm (94% vs. 75%, P < 0.001*). A subgroup analysis of children (n = 58, 12 ± 4 years old, 55% female) revealed superiority to the Arruda algorithm (P < 0.001*). The reproducibility of our algorithm was excellent (ϰ>0.8; P < 0.001*). The novel EASY-WPW algorithm provides reliable and accurate pre-interventional ablation site determination in WPW patients. Only two steps are necessary to locate left-sided AP, and three steps to determine right-sided AP.

23 February 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
VSVanessa Sciacca
Vanessa Sciacca
TFThomas Fink
Thomas Fink
HKHermann Körperich
Hermann Körperich
LBLeonard Bergau
Leonard Bergau
DGDenise Guckel
Denise Guckel
CSChristian Sohns
Christian Sohns
Atrial fibrillation (AF) ablation protocols using energy delivery with very high power and short duration (vHPSD) have been introduced to improve lesion formation. This study reports procedural data of vHPSD ablation in AF patients and analyses characteristics of ablation-induced left atrial (LA) scar formation from cardiac magnetic resonance imaging (MRI). Sixty consecutive patients undergoing index pulmonary vein isolation following our institutional Q4U-AF workflow were prospectively enrolled. Ablation was conducted using a contact force sensing catheter allowing for vHPSD ablation using a temperature-controlled ablation mode. Thirty patients underwent cardiac late gadolinium enhancement MRI of the LA 3 months after ablation to assess LA scar. Mean procedural duration was 66.5 ± 14.8 min. Mean ablation time was 4.7 ± 0.9 min with a mean number of 69.9 ± 14.2 applications. First-pass isolation was achieved in 51 patients (85%) for the right pulmonary veins (RPVs), in 37 patients (61.7%) for the left pulmonary veins (LPVs), and in 34 patients (56.7%) for both pulmonary veins (PVs). Magnetic resonance imaging at 3 months post-ablation demonstrated a mean scar width of 14.4 ± 2.6 mm around RPVs and 11.9 ± 1.9 mm at LPVs (P > 0.05). Complete PV encirclement was observed in 76.7% for RPVs, in 76.7% for LPVs, and in 66.7% for both PV pairs. During a mean follow-up of 4.7 ± 1.4 months, arrhythmia recurrence was observed in 3.3% of the patients. Pulmonary vein isolation following a novel vHPSD workflow resulted in short procedure duration and high acute and mid-term efficacy. Magnetic resonance imaging demonstrated durable and transmural PV lesions with homogeneous and contiguous scar formation.