Pramod Agarwal

Prof. Dr. Pramod Agarwal


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
NUNitin Upadhyay
Nitin Upadhyay
NPNarayana Prasad Padhy
Narayana Prasad Padhy
PAPramod Agarwal
Pramod Agarwal
The inverter-current proportional feedback (ICPF) active damping (AD) for an LCL grid-connected inverter (LCL-GCI) suffers from adverse gain reduction and loss of inductive ability in the low-frequency zone, making it unsuitable for active damping. To overcome the limitations of ICPF-AD, inverter-current bandpass filter feedback (ICBFF) AD is more conducive to suppressing the resonance of LCL-GCI. However, it is found that the system time delay constrains the damping capability of ICBFF-AD to resonance frequencies lower than those achievable with ICPF-AD. Therefore, this article proposes a second-order lead filter (SOLF) in cascade with the bandpass filter (BF) as an AD controller for inverter-current feedback AD. The analysis illustrates that cascading a SOLF with BF in the AD loop preserves the LCL filter's low-frequency gain and inductive nature resulting in improved dynamic response as compared to the ICPF-AD. Additionally, the cascaded filter AD allows the damping of higher resonance frequency with better noise immunity. The design approach for BF and SOLF is proposed and the effectiveness of the cascaded AD controller in the presence of different grid impedance is presented. The experimental results from a 10 kW laboratory setup corroborate the theoretical analysis.

22 January 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ASAshesh M. Shah
Ashesh M. Shah
BBBhavesh R. Bhalja
Bhavesh R. Bhalja
RPRajesh M. Patel
Rajesh M. Patel
HBHet Bhalja
Het Bhalja
PAPramod Agarwal
Pramod Agarwal
OMOm Malik
Om Malik

1 January 2014 in International Journal of Power and Energy Conversion
Verified
Journal Article
Closed access
AMAmbarisha Mishra
Ambarisha Mishra
PAPramod Agarwal
Pramod Agarwal
SSS.P. Srivastava
S.P. Srivastava
Permanent magnet synchronous motor (PMSM) is gaining much attention in the area of high performance drives with the recent development in solid state electronics, processors, and intelligent computing. The development of ASIC and advanced VLSI technologies compact size and high efficiency of PMSM made it a suitable candidate for servo drives. This paper describes a brief analysis of permanent PMSM. The advantages over widely used DC motors and induction motors are also discussed in detail. To overcome the inherent coupling effect and the sluggish response of scalar control the vector control is employed. By using the vector control, the performance of AC machines can be made similar to that of a DC machine. To implement the vector control two-axis mathematical model in d-q reference frame is obtained. The performance of proposed controller is investigated for different speed and torque values. The effectiveness of proposed controller is verified through simulations.

1 December 2012
Verified
Conference Paper
Closed access
AMAmbarisha Mishra
Ambarisha Mishra
VMVasundhara Mahajan
Vasundhara Mahajan
PAPramod Agarwal
Pramod Agarwal
SSS.P. Srivastava
S.P. Srivastava
To achieve a high dynamics performance vector control of PMSM drive is employed. In vector control stator current is decomposed into two parts- flux generating component and torque generating component. These two currents require separate control to control the flux and torque produced by motor separately like dc machine. The complete drive has two loops- inner current control loop, and outer speed control loop. In this paper fuzzy-logic is employed and investigated for all three controllers (one as speed controller and two as current controllers). Fuzzy logic controllers are used with input and output scaling factors. Each controller has their separate input and output range, so tuning (selection of scaling factors) of three controllers are different. Tuning is done observing the values at input and output of controller by using PI controller by keeping the interval of membership function [-2 2] in mind. Simulation is done in MATLAB for various operating conditions. Simulation results show the validity of proposed controllers.

1 January 2009
Verified
Conference Paper
Closed access
TCThanga Raj Chelliah
Thanga Raj Chelliah
JYJ.G. Yadav
J.G. Yadav
SSS.P. Srivastava
S.P. Srivastava
PAPramod Agarwal
Pramod Agarwal
This paper presents simulation studies on the optimal energy control of an inverter-fed three-phase induction motor (1 hp). An overview of various controllers: loss model controller, search controller and their hybridization are given. Induction motor parameter variations due to temperature rise and core saturation are considered when loss models are derived. Mine hoist drive of a mineral industry and the implementation of efficiency optimization controllers with the help of particle swarm optimization (PSO) and fuzzy logic are given. Fuzzy pre-compensated proportional integral (FPPI) is used to improve motor's dynamic performances during the activation of optimal energy control. Analysis shows that it is possible to conserve energy in Indian industries by choosing several possible ways of implementing optimal energy control.

18 March 2025 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
RRRayaprolu. M. Raghuveer
Rayaprolu. M. Raghuveer
BBBhavesh R. Bhalja
Bhavesh R. Bhalja
PAPramod Agarwal
Pramod Agarwal
This study presents a real-time energy management approach for multiple electric vehicle charging stations (EVCSs), which are integrated with photovoltaic (PV) systems, wind turbines (WTs), and battery energy storages (BESs) in an active distribution network (ADN). The proposed optimization framework is developed as a mixed-integer second order cone programming problem that aims to minimize the operating cost while minimizing the accelerated aging of substation transformer and meeting the electric vehicle (EV) users driving needs. Additionally, it also fulfills power flow and voltage constraints of ADN ensuring global optimum which is achieved by scheduling both active and reactive powers of EVs and BESs, respectively. Furthermore, to address the real-time uncertainties associated with EVs, the developed algorithm is operated using dynamic prediction horizon based model predictive control technique. The proposed algorithm is applied on a modified IEEE-33 bus radial ADN, and its effectiveness is validated through a practical case study integrating both residential and workplace EVCSs. Additionally, the scalability of the proposed method is tested using a modified IEEE 118-bus distribution network. The results indicate substantial cost savings, significant reduction in the peak demand of the substation transformer along with its reduced loss-of-life, decreased energy loss while improving the voltage profile and better fulfillment of the EV driving requirements when compared to conventional EV charging methods.