Shanshan Yin

Mrs. Shanshan Yin

College of Information Engineering, Henan University of Science and Technology, Luoyang, Henan, China
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2024 in Computers and Electrical Engineering
Verified
Journal Article
Closed access
JWJun Wang
Jun Wang
HCHaoran Chen
Haoran Chen
YSYifei Si
Yifei Si
YZYonghai Zhu
Yonghai Zhu
TZTianci Zhu
Tianci Zhu
BLBo Liu
Bo Liu

18 November 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Shanshan YinShanshan Yin
Shanshan Yin
XLXiaohua Li
Xiaohua Li
JLJiewen Li
Jiewen Li
DLDui Liu
Dui Liu
ZCZexiang Cai
Zexiang Cai
The safety of converters is key to the stable operation of AC/DC hybrid power grids after AC faults. Thyristor valve current is a direct manifestation of the converter observability, but there are no measuring elements inside the converter, so the thyristor valve current can be reflected only indirectly through external electrical quantities. This paper proposes a virtual measurement scheme based on the temporal features of the converter terminal current. First, under the action of the trigger pulse, the polarity characteristics of the AC current and temporal features between the valves are utilized to predictive estimate the valve state. Then, when commutation failures occur and the bypass paths form, the conduction state of valve is constructed based on the relationship between AC and DC current. Last, when the valve is to be shut-off in the bypass path, the blocking state of the valve is corrected based on the unidirectional conductance characteristics of the valve. According to the above analysis, combined with the topological current equation of the converter, the valve current can be calculated in the whole process. Through the simulation of the different valve states and bypass paths and analysis of the field record data, the results show that the valve current can still be accurately calculated based on the virtual measurement scheme.

6 September 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
XLXiaohua Li
Xiaohua Li
JLJiewen Li
Jiewen Li
HLHao Li
Hao Li
Shanshan YinShanshan Yin
Shanshan Yin
ZCZexiang Cai
Zexiang Cai
Commutation failure (CF) increases the current flowing through the converter and endangers the converter. To protect the converter, CF protection is used in high voltage direct current systems. The core of CF protection is accurate CF detection. Owing to the nonlinear characteristics of converter and the rapid control, the conventional differential current method used to detect CF faces challenges. This article proposes a method to detect CF directly by tracking commutation process. The study indicates that the characteristics of commutation process differ significantly between normal operation and CF. By extracting these characteristics, commutation process can be tracked, and CF can be detected. For improving reliability, the proposed method depends on the relative relationship between AC current and DC current, reducing the influence of current fluctuation. Temporal and amplitude characteristics are both extracted to judge commutation process state and detect CF. The performance of the proposed scheme is validated using an actual engineering model and recorded engineering data. The results indicate that the proposed method can effectively detect CF under different scenarios.

26 May 2025 in Engineering Applications of Artificial Intelligence
Verified
Journal Article
Closed access
KZKaiyang Zhang
Kaiyang Zhang
JWJun Wang
Jun Wang
YZYonghai Zhu
Yonghai Zhu
YSYifei Si
Yifei Si
Shanshan YinShanshan Yin
Shanshan Yin
HZHang Zhang
Hang Zhang

Verified
Journal Article
Open access
PDF file
Shanshan YinShanshan Yin
Shanshan Yin
PMPengjun Mao
Pengjun Mao
WLWenjun Li
Wenjun Li
Smart transformation and green development are the core research directions of electric vehicles. An electric tractor is powered by the vehicle battery. The motor converts electric energy into mechanical energy and drives the wheels through the drive train. Therefore, the electric tractor model is a modular mathematical model for the battery, motor, drive train, and drive wheel. A class of high-order terminal sliding mode control strategies is adopted to establish the relative rotational angles of drive wheels, driving angular speeds, and motor angular speeds as input, and driving angular speeds and motor angular speeds as output. This process ensures stable operating speed and good working quality under the operating conditions and achieves small-scale unattended driving. The output is a nonlinear system state equation. An n-order derivative continuous function is introduced to design the terminal sliding surface of the sliding mode. A control function to reduce chattering is also designed to ensure that the output function converges at the finite time and the existing sliding stage achieves zero steady-state error. Simulation results of the whole electric tractor model show that the speed remains stable under the condition of outside interference, and experiments verify the feasibility of the control strategy.

15 June 2023 in IEEE Access
Verified
Journal Article
Open access
Shanshan YinShanshan Yin
Shanshan Yin
When an AC fault occurs in HVDC transmission system, the transient response change in the rate of change of current and voltage, which may lead to the unexpected action behavior of converter protection. This is attributed to the electrical quantity similarities between internal and external faults, leading to difficulties in fault location identification and reducing the sensitivity in protection measure activation. To realize internal and external fault identification and quickly deal with external faults, an AC fault detection method for LCC-HVDC systems based on virtual conduction width characteristics is proposed. First, by utilizing the ratio integral of the three-phase AC current on the valve side to the reference current, the virtual conduction width flowing through each valve in the sampling window is calculated. Second, according to the size relationship among virtual conduction widths, internal and external faults are identified. Third, after determining the external faults, the difference in the virtual conduction width for each valve branch in the sampling window is calculated to locate the fault phase. Finally, the simulation results based on EMTDC/PSCAD show that the proposed method can quickly identify internal and external faults and locate fault phases and is not affected by fault moment and fault resistance.