Communication-assisted protection and self-healing control (CAPSC) is perceived as a new alternative to ensure reliable operation of distribution networks (DNs) because of its prominent advantages of information sharing. Although the application of CAPSC based on IEC 61850 has been verified in substations, it has not yet been effectively promoted in DNs. To fully exert its advantages in DNs, a novel scheme of IEC 61850-based CAPSC is proposed in this paper. The proposed scheme enable samplings to be synchronized by propagation delay compensation without external clocks. Adaptive execution algorithms of protection and self-healing control are introduced considering changeable topology and configuration conditions. The coordination between protection and self-healing control in this scheme is simplified by component state descriptions instead of event signals. The scheme proposed in this paper has been incorporated in an engineering field application. A closed-loop test has been conducted on a real-time digital simulator (RTDS) according to the field connections and parameters to verify the rationality and effectiveness of the proposed scheme.
19 April 2023 in IEEE Transactions on Power Systems
In the multi-infeed LCC-HVDC system, the concurrent commutation failure (CCF) caused by the AC fault of the receiving-end system may lead to the blocking of multiple converter stations, which challenges power grid security and stability. This paper proposes a novel method to quickly and accurately identify the CF risk areas, considering the CF probability (CFP) during the single-line-to-ground (SLG) fault. First, an AC-DC voltage asymmetry factor (ADVAF) and its theoretical derivation are proposed to quantify the influence of the fault position on the CF. Second, the critical ADVAF (CADVAF) is derived based on the equivalent method. By comparing ADVAF and CADVAF, the CF risk areas can be quickly divided into non-, possible- and inevitable-concurrent CF risk areas. Third, the relationship between local CFP (LCFP) and fault position is established, and the concurrent CFP (CCFP) is calculated. The proposed method has improved the accuracy and computational efficiency of theoretical analysis than earlier methods. Finally, the validity and accuracy of the proposed method are verified in dual-infeed and five-infeed LCC-HVDC systems built based on the IEEE 39-bus and IEEE 118-bus models, respectively.
COVID-19 is a public health emergency for human beings and brings some very harmful consequences in social and economic fields. In order to model COVID-19 and develop the effective control measures, this paper proposes an SEIR-type epidemic model with the contacting distance between the healthy individuals and the asymptomatic or symptomatic infected individuals, and the immigration rate of the healthy individuals since the contacting distance and the immigration rate are two critical factors which determine the transmission of COVID-19. Firstly, the threshold values of the contacting distance and the immigration rate are obtained to analyze the presented model. Secondly, based on the data from January 10, 2020, to March 18, 2020, for Wuhan city, all parameters are estimated. Finally, based on the estimated parameters, the sensitivity analysis and the numerical study are conducted. The results show that the contacting distance and the immigration rate play an important role in controlling COVID-19. Meanwhile, the extinct lag decreases as the contacting distance increases and/or the immigration rate decreases. Our study could give some reasonable suggestions for the health officials and the public and provide a theoretical issue for globally controlling the COVID-19 pandemic.
The application of power electronics can introduce flexibility into power systems, but it can also cause harmonic problems. As a typical application of power electronics, high-voltage direct current (HVDC) transmission exhibits very prominent harmonic problems. In recent years, many HVDC protection maloperation events caused by harmonic problems have occurred in the field. The phenomena of harmonic transfer and amplification in HVDC transmission have an undeniable impact on the overall operation of a power system. Previous studies of these phenomena have relied mainly on detailed electromagnetic transient simulations. However, these simulations normally suffer from a large computational burden and low efficiency due to the complexity of the models and the small simulation time steps used. Therefore, an efficient analysis model of harmonics for various HVDC operating modes is presented in this paper. This model is based on port theory; every part of the HVDC transmission system is represented by an equivalent two-port component to construct a unified equivalent circuit. The proposed model is simple to calculate, and only the connections of the two-port components need to be changed to model different operation modes. The proposed two-port model is applied for the harmonic analysis of an HVDC transmission system, and the validity and accuracy of the model are confirmed by detailed electromagnetic simulations. Moreover, the model can be easily applied to HVDC systems for harmonic transfer and amplification, and the effects of the HVDC transmission power and smoothing reactor on harmonic transfer and amplification are analyzed.
Battery storage (BS) sizing problems for grid-connected microgrids (GCμGs) commonly use stochastic scenarios to represent uncertain natures of renewable energy and load demand in the GCμG. Though taking a large number of stochastic scenarios into consideration can deliver a relatively accurate optimal result, it can also highly deteriorate the computational efficiency of the sizing problem. To make an accuracy-efficiency trade-off, a computationally efficient optimization method to optimize the BS capacities based on the power exchanging process of the GCμG is proposed in this paper. According to the imbalanced power of the GCμG, this paper investigates the power exchanging process between the GCμG, BS and external grid. Motivated by the BS dynamics, a forward/backward sweep-based energy management scheme is proposed based on the power exchanging process. A heuristic two-level optimization model is developed with sizing BS as the upper-level problem and optimizing the operational cost of the GCμG as the lower-level problem. The lower-level problem is solved by the proposed energy management scheme and the objective function of the upper-level is minimized by the pattern search (PS) algorithm. To validate the accuracy and computational efficiency of the proposed method, the numerical results are compared with the mixed integer linear programming (MILP) method. The comparison shows that the proposed method shares similar accuracy but is much more time-efficient than the MILP method.
18 November 2021 in IEEE Transactions on Power Delivery
The safety of converters is key to the stable operation of AC/DC hybrid power grids after AC faults. Thyristor valve current is a direct manifestation of the converter observability, but there are no measuring elements inside the converter, so the thyristor valve current can be reflected only indirectly through external electrical quantities. This paper proposes a virtual measurement scheme based on the temporal features of the converter terminal current. First, under the action of the trigger pulse, the polarity characteristics of the AC current and temporal features between the valves are utilized to predictive estimate the valve state. Then, when commutation failures occur and the bypass paths form, the conduction state of valve is constructed based on the relationship between AC and DC current. Last, when the valve is to be shut-off in the bypass path, the blocking state of the valve is corrected based on the unidirectional conductance characteristics of the valve. According to the above analysis, combined with the topological current equation of the converter, the valve current can be calculated in the whole process. Through the simulation of the different valve states and bypass paths and analysis of the field record data, the results show that the valve current can still be accurately calculated based on the virtual measurement scheme.