In critical healthcare units, such as operation theaters and intensive care units, healthcare workers require specific temperature environments at different stages of an operation, which depends upon the condition of the patient and the requirements of the surgical procedures. Therefore, the need for a dynamically controlled temperature environment and the availability of the required heating/cooling electric power is relatively more necessary for the provision of a better healthcare environment as compared to other commercial and residential buildings, where only comfortable room temperature is required. In order to establish a dynamic temperature zone, a setpoint regulator is required that can control the zone temperature with a fast dynamic response, little overshoot, and a low settling time. Thus, two zone temperature regulators have been proposed in this article, including double integral sliding mode control (DISMC) and integral terminal sliding mode control (ITSMC). A realistic scenario of a hospital operation theater is considered for evaluating their responses and performance to desired temperature setpoints. The performance analysis and superiority of the proposed controllers have been established by comparison with an already installed Johnson temperature controller (JTC) for various time spans and specific environmental conditions that require setpoints based on doctors’ and patients’ desires. The proposed controllers showed minimal overshoot and a fast settling response, making them ideal controllers for operation theater (OT) zone temperature control.
9 June 2026 in IEEE Transactions on Industry Applications
Photovoltaic (PV) systems are widely deployed renewable sources, yet their performance and reliability are often undermined by operational faults. This paper presents a novel weather-driven fault classification framework for PV predictive maintenance (PdM), addressing a key limitation of existing studies that analyse faults under fixed, short-term or simplified weather assumptions. The major contribution of this work lies in explicitly modelling variability in both solar irradiance and temperature across four distinct weather conditions, enabling the separation of weather-induced variations from true fault signatures. Features are extracted from IV characteristics under varying weather scenarios and processed through a regression-based residual analysis with a pre-feature assessment stage, generating deviation patterns and feature contribution signatures. These enhanced feature vectors are then classified using a Bayesian-optimised gradient boosting model within a two-stage architecture that (1) distinguishes normal vs. abnormal operation and (2) identifies either the prevailing weather condition (if normal) or classifies the fault type together with its corresponding weather scenario (if abnormal). The robustness and generalisability of the framework are validated using cross-validation, high-fidelity simulations, and independent laboratory experiments, achieving 99% classification accuracy. By directly linking each detected fault to its prevailing weather condition, the proposed approach provides a robust pathway for weather-aware PdM scheduling, improving diagnostic reliability and operational resilience across diverse environments.