JIE YA WANG

Dr. JIE YA WANG


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2022 in Catalysts
Verified
Journal Article
Open access
PDF file
KWKexin Wang
Kexin Wang
LLLina Liu
Lina Liu
YZYongsheng Zhang
Yongsheng Zhang
JSJianfeng Su
Jianfeng Su
RSRuirui Sun
Ruirui Sun
Mingyi ZhangMingyi Zhang
Mingyi Zhang
Semiconductor materials as photocatalysts hold great prospects for renewable energy substitutes and environmental protection. Nanostructured BiOX (X=Cl, Br, I) with favorable features of a unique layered crystal structure and suitable band gaps has been demonstrated to be a promising photocatalytic material. In this paper, a two-step synthesis route combining an electrospinning technique and SILAR reaction has been accepted as a straightforward protocol for the exploitation of BiOI/carbon nanofibers’ (CNFs) hierarchical heterostructures. As expected, the BiOI/CNFs presented a much higher degradation rate of methyl orange than that of the pure BiOI under visible light. The degradation rate of methyl orange reaches 85% within 210 min. The enhanced photocatalytic activity could be attributed to the fact that conductive CNFs as substrate could effectively improve the separation and transformation of photogenerated charges. Moreover, the fabricated BiOI/CNFs after five cycles could be easily recycled without a decrease in photocatalytic activity due to their ultra-long one-dimensional nano-structural property.

17 April 2023 in Universe
Verified
Journal Article
Open access
PDF file
XLXiao-Yu Lu
Xiao-Yu Lu
JHJinshu Huang
Jinshu Huang
CLCongbin Liu
Congbin Liu
XXXiu-Mei Xu
Xiu-Mei Xu
JCJinbing Cheng
Jinbing Cheng
JWJIE YA WANG
JIE YA WANG
The clock comparison experiments to test special relativity mainly include the Michelson–Morley experiment, Kennedy–Thorndike experiment, Ives–Stilwell experiment and the comparison experiment of atomic clocks in two locations. These experiments can be roughly classified as the comparison of two types of clocks: optical clocks and atomic clocks. Through the comparison of such clocks, Lorentz invariance breaking parameters in the RMS framework can be tested. However, in such experiments, the structural effects of optical clocks have been fully considered, yet the structural effects of atomic clocks have not been carefully studied. Based on this, this paper analyzes the structural effects of atomic clocks in detail and divides the experiments into six types: the comparison of two atomic clocks, two optical clocks, and atomic clocks and optical clocks placed in different and the same locations. Finally, correction parameters for the experimental measurements are given.

9 September 2024 in Physica Scripta
Verified
Journal Article
Closed access
JWJIE YA WANG
JIE YA WANG
XLXiao-Yu Lu
Xiao-Yu Lu
JZJiao Zhang
Jiao Zhang
KWKe-Xin Wang
Ke-Xin Wang
JSJian-Feng Su
Jian-Feng Su
CTChun-Juan Tang
Chun-Juan Tang
With the rapid development of atom interference technology, multi-loop atom interferometers are widely used in the high-precision measurement of various physical constants and testing of various gravity-related effects. However, in ground-based multi-loop atom interference experiments, the systematic error contribution by classical effects is an important factor that affects the experimental measurement accuracy and gravitational effect detection. Based on this, we used the atomic wave-function evolution-phase accumulation method to provide a high-order interference phase of multi-loop atom interferometers in an inhomogeneous gravitational field containing Earth’s rotation. Furthermore, we propose a new scheme that combines optimised frequency-shift compensation technology with an improved pulse sequence to eliminate systematic errors due to the gravity gradient, Earth’s rotation, and their coupling effect with the pulse duration, as well as the coupling effect of laser detuning with the pulse duration. This study lays a theoretical foundation for experiments on multi-loop atom interferometers with higher precision.

3 September 2024 in Physica Scripta
Verified
Journal Article
Closed access
XLXiao-Yu Lu
Xiao-Yu Lu
JWJIE YA WANG
JIE YA WANG
ZLZhi-Gang Li
Zhi-Gang Li
The heterodyne measurements are adopted in space-based gravitational wave detectors to detect gravitational wave signals in the millihertz range. Due to the difficulty in maintaining the equal distance between these spacecrafts in the detector, laser phase noise is a main noise in the detection process, so time-delay interferometry combination is adopted to eliminate this noise by synthesizing virtual equal arm interferometry. However, when conducting heterodyne laser interferometry measurements in space-based gravitational wave detection, clock noise is also introduced into the measurement, but the analytical results of clock noise have been ignored in previous studies. Based on time-delay interferometry combination, we analyze the impact of clock noise and provide analytical results of the total noise in various data combinations. Through this result, we evaluate the required clock accuracy of 10−16 for the gravitational wave detector when clock noise is not reduction, so the analytical result can more intuitively reflect how the clock noise effects the sensitivity of the detector.