Alain Hoornaert

Dr. Alain Hoornaert

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Acta Biomaterialia
Verified
Journal Article
Closed access
LSLaëtitia Salou
Laëtitia Salou
AHAlain Hoornaert
Alain Hoornaert
Guy LouarnGuy Louarn
Guy Louarn
Pierre LayrollePierre Layrolle
Pierre Layrolle

12 February 2020 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
LVluciano vidal
luciano vidal
CKCarina Kampleitner
Carina Kampleitner
MBMeadhbh Á. Brennan
Meadhbh Á. Brennan
AHAlain Hoornaert
Alain Hoornaert
Pierre LayrollePierre Layrolle
Pierre Layrolle
The healing of bone fractures is a well-orchestrated physiological process involving multiple cell types and signaling molecules interacting at the fracture site to replace and repair bone tissue without scar formation. However, when the lesion is too large, normal healing is compromised. These so-called non-union bone fractures, mostly arising due to trauma, tumor resection or disease, represent a major therapeutic challenge for orthopedic and reconstructive surgeons. In this review, we firstly present the current commonly employed surgical strategies comprising auto-, allo-, and xenograft transplantations, as well as synthetic biomaterials. Further to this, we discuss the multiple factors influencing the effectiveness of the reconstructive therapy. One essential parameter is adequate vascularization that ensures the vitality of the bone grafts thereby supporting the regeneration process, however deficient vascularization presents a frequently encountered problem in current management strategies. To address this challenge, vascularized bone grafts, including free or pedicled fibula flaps, or in situ approaches using the Masquelet induced membrane, or the patient’s body as a bioreactor, comprise feasible alternatives. Finally, we highlight future directions and novel strategies such as 3D printing and bioprinting which could overcome some of the current challenges in the field of bone defect reconstruction, with the benefit of fabricating personalized and vascularized scaffolds.

8 September 2009 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
jean-christophe rozejean-christophe roze
jean-christophe roze
SBStéphanie Babu
Stéphanie Babu
ASAfchine Saffarzadeh
Afchine Saffarzadeh
MGMarie Gayet‐Delacroix
Marie Gayet‐Delacroix
AHAlain Hoornaert
Alain Hoornaert
Pierre LayrollePierre Layrolle
Pierre Layrolle

1 August 2016 in Biomedical Materials
Verified
Journal Article
Open access
PDF file
AHAlain Hoornaert
Alain Hoornaert
CDCyril D’arros
Cyril D’arros
MHMarie Françoise Heymann
Marie Françoise Heymann
Pierre LayrollePierre Layrolle
Pierre Layrolle
Membranes for guided bone regeneration (GBR) were prepared from the synthetic biodegradable polymer poly-D,L-lactic/glycolic acid (PLGA). This GBR membrane has a bi-layered structure with a dense film to prevent gingival fibroblast ingrowth and ensure mechanical function, and a micro-fibrous layer to support colonization by osteogenic cells and promote bone regeneration. Hydrolysis and biodegradation were both studied in vitro through soaking in phosphate buffered saline (PBS) and in vivo by implantation in the subcutis of rats for 4, 8, 16, 26, 48 and 52 weeks. Histology revealed an excellent colonization of the micro-fibrous layer by cells with a minimal inflammatory reaction during resorption. GBR using the synthetic PLGA membrane was evaluated on critical-size calvaria defects in rats for 4 and 8 weeks. Radiographs, micro-computed tomography and histology showed bone regeneration with the PLGA membrane, while the defects covered with a collagen membrane showed a limited amount of mineralized bone, similar to that of the defect left empty. The biofunctionality of the PLGA membranes was also compared to collagen membranes in mandible defects in rabbits, associated or not with beta-tricalcium phosphate granules. This study revealed that the bi-layered synthetic membrane made of PLGA was safer, more biocompatible, and had a greater controlled resorption rate and bone regeneration capacity than collagen membranes. This new PLGA membrane could be used in pre-implantology and peri-odontology surgery.

30 July 2012 in Nanomedicine
Verified
Journal Article
Closed access
SLSandrine Lavenus
Sandrine Lavenus
VTValérie Trichet
Valérie Trichet
SCSébastien Le Chevalier
Sébastien Le Chevalier
AHAlain Hoornaert
Alain Hoornaert
Guy LouarnGuy Louarn
Guy Louarn
Pierre LayrollePierre Layrolle
Pierre Layrolle
We aimed to study the interactions between human mesenchymal stem cells and the bone integration of nanostructured titanium implants. Nanopores of 20, 30 and 50 nm were prepared by anodization of titanium at 5, 10 and 20 V in a mixture of fluorhydric and acetic acid. Ti 30 and 50 nanostructures promoted early osteoblastic gene differentiation of the human mesenchymal stem cells without osteogenic supplements. The osseointegration of nanostructured and control titanium implants was compared by implantation in rat tibias for 1 and 3 weeks. The nanostructures significantly accelerated bone apposition and bone bonding strength in vivo in correlation with in vitro results. These findings demonstrate that specific nanostructures controlled the differentiation of cells and, thus, the integration of implants in tissues. These nanoporous titanium surfaces may be of considerable interest for dental and orthopedic implants.

1 September 2020 in Acta Biomaterialia
Verified
Journal Article
Open access
LVluciano vidal
luciano vidal
MBMeadhbh Á Brennan
Meadhbh Á Brennan
SKStéphanie Krissian
Stéphanie Krissian
JLJulien De Lima
Julien De Lima
AHAlain Hoornaert
Alain Hoornaert
Pierre LayrollePierre Layrolle
Pierre Layrolle
Reconstructing large bone defects caused by severe trauma or resection of tumors remains a challenge for surgeons. A fibula free flap and its vascularized bed can be transplanted to the reconstruction site to achieve healing. However, this technique adds morbidity, and requires microsurgery and sculpting of the bone tissue to adapt the graft to both the vasculature and the anatomy of the defect. The aim of the current study was to evaluate an alternative approach consisting of the in situ production of a pre-vascularized synthetic bone graft and its subsequent transplantation to a critical-sized bone defect. 3D printed chambers containing biphasic calcium phosphate (BCP) granules, perfused by a local vascular pedicle, with or without the addition of stromal vascular fraction (SVF), were subcutaneously implanted into New Zealand White female rabbits. SVF was prepared extemporaneously from autologous adipose tissue, the vascular pedicle was isolated from the inguinal site, while BCP granules alone served as a control group. After 8 weeks, the constructs containing a vascular pedicle exhibited abundant neovascularization with blood vessels sprouting from the pedicle, leading to significantly increased vascularization compared to BCP controls. Pre-vascularized synthetic bone grafts were then transplanted into 15 mm critical-sized segmental ulnar defects for a further 8 weeks. Micro-CT and decalcified histology revealed that pre-vascularization of synthetic bone grafts led to enhanced bone regeneration. This pre-clinical study demonstrates the feasibility and efficacy of the in situ production of pre-vascularized synthetic bone grafts for regenerating large bone defects, thereby addressing an important clinical need. STATEMENT OF SIGNIFICANCE: The current gold standard in large bone defect regeneration is vascularized fibula grafting. An alternative approach consisting of in situ production of a pre-vascularized synthetic bone graft and its subsequent transplantation to a bone defect is presented here. 3D printed chambers were filled with biphasic calcium phosphate granules, supplemented with autologous stromal vascular fraction and an axial vascular pedicle and subcutaneously implanted in inguinal sites. These pre-vascularized synthetic grafts were then transplanted into critical-sized segmental ulnar defects. Micro-CT and decalcified histology revealed that the pre-vascularized synthetic bone grafts led to higher bone regeneration than non-vascularized constructs. An alternative to vascularized fibula grafting is provided and may address an important clinical need for large bone defect reconstruction.