Roland Leigh

Prof. Roland Leigh

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
PPPhilip Peterson
Philip Peterson
AAAmrita Aujla
Amrita Aujla
KGKirsty H. Grant
Kirsty H. Grant
ABAlex G. Brundle
Alex G. Brundle
MTMartin Thompson
Martin Thompson
RLRoland Leigh
Roland Leigh
The potential of inexpensive Metal Oxide Semiconductor (MOS) gas sensors to be used for urban air quality monitoring has been the topic of increasing interest in the last decade. This paper discusses some of the lessons of three years of experience working with such sensors on a novel instrument platform (Small Open General purpose Sensor (SOGS)) in the measurement of atmospheric nitrogen dioxide and ozone concentrations. Analytic methods for increasing long-term accuracy of measurements are discussed, which permit nitrogen dioxide measurements with 95% confidence intervals of 20.0 μ g m − 3 and ozone precision of 26.8 μ g m − 3 , for measurements over a period one month away from calibration, averaged over 18 months of such calibrations. Beyond four months from calibration, sensor drift becomes significant, and accuracy is significantly reduced. Successful calibration schemes are discussed with the use of controlled artificial atmospheres complementing deployment on a reference weather station exposed to the elements. Manufacturing variation in the attributes of individual sensors are examined, an experiment possible due to the instrument being equipped with pairs of sensors of the same kind. Good repeatability (better than 0.7 correlation) between individual sensor elements is shown. The results from sensors that used fans to push air past an internal sensor element are compared with mounting the sensors on the outside of the enclosure, the latter design increasing effective integration time to more than a day. Finally, possible paths forward are suggested for improving the reliability of this promising sensor technology for measuring pollution in an urban environment.

1 June 2017 in Environmental Pollution
Verified
Journal Article
Open access
AJA.P.R. Jeanjean
A.P.R. Jeanjean
JGJohn Gallagher
John Gallagher
PMP.S. Monks
P.S. Monks
RLRoland Leigh
Roland Leigh
Air pollution continues to be a problem in the urban environment. A range of different pollutant mitigation strategies that promote dispersion and deposition exist, but there is little evidence with respect to their comparative performance from both an environmental and economic perspective. This paper focuses on examining different NO2 mitigation strategies such as trees, buildings facades coated with photocatalytic paint and solid barriers in Oxford Street in London. The case study findings will support ranking the environmental and economic impacts of these different strategies to improve personal exposure conditions on the footpath and on the road in a real urban street canyon. CFD simulations of airflow and NO2 dispersion in Oxford Street in London were undertaken using the OpenFOAM software platform with the k-ε model, taking into account local prevailing wind conditions. Trees are shown to be the most cost-effective strategy, with a small reduction in NO2 concentrations of up to 0.7% on the road. However, solid barriers with and without the application of photocatalytic paint and an innovative material (20 times more expensive than trees) can improve air quality on the footpaths more substantially, up to 7.4%, yet this has a significant detrimental impact on NO2 concentrations (≤23.8%) on the road. Photocatalytic paint on building surfaces presented a minimal environmental reductions (1.2%) and economic (>100 times more expensive than trees) mitigation strategy. The findings recognised the differences between footpath and road concentrations occurred and that a focused examination of three pollution hotspots can provide more cost effective pollution mitigation. This study considers how a number of pollutant mitigation measures can be applied in a single street canyon and demonstrates the strengths and weaknesses of these strategies from economic and environmental perspectives. Further research is required to extrapolate the findings presented here to different street geometries.

26 November 2009 in Atmospheric Environment
Verified
Journal Article
Closed access
DWDavid Worton
David Worton
CRClaire E. Reeves
Claire E. Reeves
SPStuart A. Penkett
Stuart A. Penkett
WSWilliam Sturges
William Sturges
JSJana Slemr
Jana Slemr
SSShona C. Smith
Shona C. Smith

24 March 2015 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
JAJ. S. Anand
J. S. Anand
PMP. S. Monks
P. S. Monks
RLRoland Leigh
Roland Leigh
A novel tropospheric NO2 DOAS retrieval algorithm optimised for a nadir-viewing satellite instrument imaging polluted areas is proposed in this work. Current satellite DOAS retrievals have relied on using a solar reference spectrum to derive a total slant column, then using either model assimilation or spatial filtering to derive the tropospheric component. In the ERrs-DOAS (Earth radiance reference sector DOAS) algorithm, tropospheric NO2 slant columns are derived using spectra averaged from measurements over unpolluted regions, thus removing the need for post-hoc separation techniques, though some residual stratospheric biases may still remain. To validate the ERrs-DOAS algorithm, DOAS retrievals were performed on modelled spectra created by the radiative transfer model SCIATRAN, as well as L1B Earth radiance data measured by the NASA/KNMI Ozone Monitoring Instrument (OMI). It was found that retrievals using an Earth radiance reference produce spatial distributions of tropospheric NO2 over eastern China during June 2005 that highly correlate with those derived using existing retrieval algorithms. Comparisons with slant columns retrieved by the operational NO2 retrieval algorithm for OMI (OMNO2A) show that the ERrs-DOAS algorithm greatly reduces the presence of artificial across-track biases (stripes) caused by calibration errors, as well as the removal of path length enhancement in off-nadir pixels. Analysis of Pacific SCDs suggests that the algorithm also produces a 27% reduction in retrieval uncertainty, though this may be partially due to biases introduced by differences in the retrieval algorithm settings. The ERrs-DOAS technique also reveals absorption features over the Sahara and similar regions characteristic of sand and liquid H2O absorption, as first discovered in the analysis of GOME-2 NO2 retrievals.

5 September 2018 in Aerosol Science and Technology
Verified
Journal Article
Open access
JHJoshua D. Vande Hey
Joshua D. Vande Hey
HSHannah Sonderfeld
Hannah Sonderfeld
AJAntoine P. R. Jeanjean
Antoine P. R. Jeanjean
RPRikesh Panchal
Rikesh Panchal
RLRoland Leigh
Roland Leigh
PMPaul S. Monks
Paul S. Monks
Poor air quality inside vehicles and its impact on human health is an issue requiring attention, with drivers and passengers facing levels of air pollution potentially greater than street-side outdoor air. This paper assesses the potential effectiveness of a car cabin filtration system to remove fine particulate matter PM2.5 and improve air quality for car passengers. The study was conducted as a practical evaluation coupled to a model implementation. First, the effectiveness of PM2.5 filter material was investigated in a chamber experiment under a range of environmental and loading conditions using a realistic automotive auxiliary scrubber. Second, implementation of such a system was evaluated in a full air flow 3D computational fluid dynamical model configured for a realistic cabin and ventilation system, and related to the chamber results through a simple decay model. Additionally, performance of low-cost dust sensors was evaluated as potential cabin monitoring devices. The experiment and modeling support the feasibility of a robust system which could be integrated into automotive designs in a straightforward manner. Results suggest that an auxiliary scrubber in the rear of the cabin alone would provide suboptimal performance, but that by incorporating a PM2.5 filter into the main air handling system, cabin PM2.5 concentrations could be reduced from 100 µg m−3 to less than 25 µg m−3 in 100 s and to 5 µg m−3 in 250 s. A health impact assessment for hypothetical occupational driver populations using such technology long term showed considerable reductions in indicative PM2.5 attributable mortality. Copyright © 2018 The Authors. Published with license by Taylor & Francis Group, LLC