Łukasz Macioszek

Dr. Łukasz Macioszek

Inst. of Metrology, Electronics and Computer Sc., University of Zielona Góra, Zielona Góra, Lubuskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
ŁMŁukasz Macioszek
Łukasz Macioszek
SWSylwia Włodarczak
Sylwia Włodarczak
RRRyszard Rybski
Ryszard Rybski
In this study, an attempt was made to evaluate very small water content (below 0.05% in volume) in the ‘20–30’ mineral oil using both electrochemical impedance spectroscopy (EIS) and dielectric constant calculation based on the measured impedance values. Measurements were performed with the use of laboratory EIS system and were designed to verify experimentally that it is possible to develop an IS‐based measuring system that would be able to work in situ, be relatively cheap and fast alternative compared with systems widely used nowadays. Known amounts of water were added to the oil samples, which were not treated by any other factors, e.g. solvents, contrary to other researchers’ findings. Impedance of the samples was measured in the frequency range of 0.01–100 Hz. Equivalent circuit was proposed and used to reveal how electric properties of the oil change due to water addition. Both calibration curves based on the value of an equivalent circuit element and dielectric constant showed linear correlation of their values with the water amount. Thus, experimental results confirm that with some discussed limitations, EIS and dielectric constant calculation can be used to estimate even such small quantities of water in mineral oil.

17 April 2024 in Energies
Verified
Journal Article
Open access
PDF file
ŁMŁukasz Macioszek
Łukasz Macioszek
DSDariusz Sobczynski
Dariusz Sobczynski
Diesel is consistently a very popular fuel for internal combustion engines. Its consumption in the European Union has been rising over recent years, as has the number of engines increasingly sensitive to fuel contamination. One of the most important parameters affecting diesel quality is water content. Its exceedance of the standard’s permissible amount carries the risk of serious damage to expensive, modern fuel injection systems. Current methods of measuring water content require both specialised personnel and equipment, as well as transporting the sample to a suitable laboratory. Analysing the properties of diesel is challenging, mainly because many types of the fuel are sold, the chemical composition of which is always a well-guarded manufacturer’s secret. The research presented in this paper is aimed at verifying whether it is possible to test the moisture content of diesel using impedance spectroscopy. To date, it is the first such attempt with commercially available diesel using this method, which, once refined, could be used in situ. The authors propose and apply a novel technique that is able to be used when the electrical properties of tested oils are unknown. The experimental results obtained show that it is possible to use impedance spectroscopy to estimate the water content of different types of diesel fuel. The measurement accuracy achieved makes it possible to detect approaching or exceeding the permissible water content.


27 March 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
ŁMŁukasz Macioszek
Łukasz Macioszek
DSDariusz Sobczynski
Dariusz Sobczynski
Diesel is consistently a very popular fuel for internal combustion engines. Its consumption in the European Union has been rising over recent years, as has the number of engines increasingly sensitive to fuel contamination. One of the most important parameters affecting diesel quality is water content. Although its exceedances of the standard’s permissible amount are not common, they carry the risk of serious damage to expensive, modern fuel injection systems. Current methods of measuring water content require both specialised personnel and equipment, as well as transporting the sample to a suitable laboratory. The research presented in this paper was aimed at verifying whether it would be possible to test the moisture content of diesel using impedance spectroscopy. Once refined, such measurement method could be used in situ. Analysing the properties of diesel is challenging, mainly because many types of the fuel are sold, the chemical composition of which is always a well-guarded manufacturer’s secret. The experimental results obtained on many types of commercially available diesel show that it is possible to use impedance spectroscopy to estimate the water content of different types of diesel fuel. The measurement accuracy achieved makes it possible to detect approaching or exceeding the permissible water content.

11 November 2022 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
ŁMŁukasz Macioszek
Łukasz Macioszek
SASylwia Andrzejczak-Grządko
Sylwia Andrzejczak-Grządko
JUJoanna Urbaniak
Joanna Urbaniak
Katarzyna DembińskaKatarzyna Dembińska
Katarzyna Dembińska
Zanieczyszczenie mikrobiologiczne piwa skutkuje pojawieniem się szeregu wad produktu. Celem niniejszej pracy było zastosowanie spektroskopii impedancyjnej w ocenie stopnia zanieczyszczenia mikrobiologicznego w produkcji piwa niepasteryzowanego. Uzyskane wyniki wskazują, że pomiary impedancji mogą być szybką metodą oceny stopnia zanieczyszczenia.

5 December 2016 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
ŁMŁukasz Macioszek
Łukasz Macioszek
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.