In this paper, we demonstrate a miniature energy harvesting wind velocity sensor of simple, low-cost construction, based on a single-degree-of-freedom galloping structure. The sensor consists of a prismatic bluff body with a triangular cross section attached to the free end of a cantilever incorporating a commercial polyvinylidene fluoride piezoelectric film. In the wind, the bluff body causes vibration of the cantilever based on galloping, and the piezoelectric film converts the vibration energy into an electrical signal. We have observed a negative correlation between the wind velocity and the vibration frequency, and we demonstrate that this relationship can be used to detect wind velocity directly with useful accuracy. A simple theoretical model indicates that the frequency shift can be accounted for by the effect of the axial loading due to form drag. The model shows close agreement with the experimental results. In wind tunnel tests, a prototype wind velocity sensor based on this principle could measure wind velocities from 4.45 to 10 m/s, with the measured velocity typically being within 4% of the reference value obtained using a Pitot tube.
4 December 2013 in Journal of Physics: Conference Series
Real world systems rarely vibrate at a single resonance frequency and the frequencies drift over time. Tunable devices exist, but generally need additional energy to achieve frequency adaptation. This means that the benefits in power output from this tuning need to be large enough to power the mechanism itself. Passively self-tuning systems go into resonance without requiring active control. This paper focuses on a passively self-tuning system with a proof mass that can slide freely along a clamped-clamped beam. Under external vibration, the slider moves along the beam until the system goes into resonance. A proof-of-concept design is introduced using either a copper or a steel beam and a 3D-printed ABS thermoplastic proof mass. Successful self-tuning is demonstrated in both cases. The frequencies range from 80 – 140 Hz at accelerations as low as 0.007 g rms. Results show the resonance of the beam and the position of the slider along the beam with time. Furthermore, the dynamic magnification and the proof mass position at resonance are discussed, together with the inherent non-linearities of double-clamped beam resonators. The findings support the hypothesis that the effect of the ratio between proof mass and beam mass outweighs the Duffing spring stiffening effects.
1 January 2009 in Journal of the American Society for Mass Spectrometry
The fractional open-circuit voltage (FOCV) method is extensively used in low-power energy harvesting (EH) sources to extract maximum power. For fast-varying EH sources, a fast sampling rate is required. This work theoretically analyzes the influence of the sampling time and period on the harvested power of sinusoidal EH sources. In addition, the circuit limitations to achieve a fast sampling rate are presented and circuits to deal with them proposed and implemented. Furthermore, one of the circuits is based on a novel pseudoFOCV method and achieves the fastest sampling rate. Experimental tests are performed with a 2 Hz, 1 to 3 V sinusoidal source having an output resistance of 127 Ω, and the results are shown to agree with theoretical predictions. It is shown that the harvested power increases with the sampling rate when the sampling time is negligible (sampling 15 times faster than the source frequency extracts around 99% of the maximum), and for fixed sampling times, there is an optimum sampling rate where the harvested power is maximum. The first result is generic and valid for methods other than the FOCV. Tests were also performed with a small-scale wave energy converter placed in a linear shaker emulating a sea environment. Harvested power increases by 25% with respect using a commercial FOCV unit with a low sampling rate.
Measurements of the angle-dependent ablation rates of polymers that have applications in microdevice fabrication are reported. A simple model based on Beer’s law, including plume absorption, is shown to give good agreement with the experimental findings for polycarbonate and SU8, ablated using the 193 and 248 nm excimer lasers, respectively. The modeling forms a useful tool for designing masks needed to fabricate complex surface relief by ablation.