Jonghyun Lee

Dr. Jonghyun Lee

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
SPSung Hee Park
Sung Hee Park
HLHyeji Lee
Hyeji Lee
TKTae In Kim
Tae In Kim
JLJonghyun Lee
Jonghyun Lee
SHSung Yong Han
Sung Yong Han
DKDong Uk Kim
Dong Uk Kim
Background/Objectives: Biliary tract cancer (BTC) is a rare but aggressive malignancy that requires surgical treatment. However, postoperative recurrence rates are high, and reliable predictors of recurrence are limited. This study aimed to investigate the effectiveness of cell-free DNA (cfDNA) and circulating tumor cells (CTCs) in predicting early recurrence after curative surgery and complete adjuvant therapy in patients with BTC. Methods: Twenty-four patients who underwent R0 and R1 resections and completed adjuvant therapy for BTC between September 2019 and March 2022 were followed up until March 2024. Patients were categorized into early recurrence (ER) and non-ER groups, using one year as the cutoff for recurrence. Results: The combination score derived from ultrashort fragments of cfDNA, vimentin-positive CTCs, and carbohydrate antigen (CA) 19-9 levels showed a statistically significant difference between the ER and non-ER groups (p-value < 0.001). The receiver operating characteristic curve from the combination score and CA 19-9 levels yielded areas under the curve of 0.891 and 0.750, respectively. Conclusions: Although further research is required, these findings suggest that cfDNA and CTCs may increase the accuracy of predicting postoperative recurrence in patients with BTC.

Verified
Journal Article
Open access
PDF file
SHSung Yong Han
Sung Yong Han
SJSung Ill Jang
Sung Ill Jang
DKDong Hee Koh
Dong Hee Koh
JLJonghyun Lee
Jonghyun Lee
DKDong Uk Kim
Dong Uk Kim
CKChang-Il Kwon
Chang-Il Kwon
Background and Aims: Various guidewires are used for biliary cannulation, and each one has its own characteristics affecting its effectiveness. This study aimed to measure the basic properties and evaluate the effectiveness of a newly developed 0.025-inch guidewire for selective biliary cannulation. Methods: A total of 190 patients at five referral hospitals were randomly allocated to undergo selective biliary cannulation using the newly developed guidewire (NGW group, n = 95) or a conventional guidewire (CGW group, n = 95). The primary outcome was the selective biliary cannulation rate in naïve papillae. The secondary outcome was to measure the NGW basic properties, compare them with those of the CGW, and analyze the importance of basic property differences. Results: There were no significant differences between the groups in the baseline characteristics. The primary outcome (75.8% vs. 84.2%, p = 0.102) and adverse event rate (6.3% vs. 4.2%, p = 0.374) were similar in both groups. However, compared with the CGW group, the NGW group showed a higher number of ampulla contacts (2.58 vs. 2.02, p = 0.011) and longer cannulation time (216.5 vs. 135.1 s, p = 0.016). Furthermore, the NGW group had higher maximum friction (34.6 ± 1.34 vs. 30.2 ± 4.09), lower stiffness, and better elastic resiliency. In the multivariate analysis, a curved-tip GW (OR = 0.26, 95% CI 0.11–0.62, p = 0.002) and normal papillary shape (OR = 0.39, 95% CI 0.17–0.86, p = 0.021) were contributing factors for successful selective biliary cannulation. Conclusions: The NGW group had high friction and low stiffness, characteristics affecting biliary cannulation. Clinically, the NGW group had similar success and adverse event rates as the CGW, but they showed a higher number of ampulla contacts and longer cannulation time.

23 August 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
현손현준 손
현준 손
TKTae In Kim
Tae In Kim
JLJonghyun Lee
Jonghyun Lee
SHSung Yong Han
Sung Yong Han
DKDong Uk Kim
Dong Uk Kim
GKGun-Ho Kim
Gun-Ho Kim
Background and Aims: Despite its relatively low incidence rate compared to others, pancreatic cancer has a poor prognosis owing to its late detection and poor response to systemic chemotherapy. Because the effectiveness of chemotherapy is still restricted, the need for locoregional treatment is increasing. Cryoablation is an effective and minimally invasive treatment for some cancers, but its efficiency in pancreatic cancer is limited. Despite recent reports about promising outcomes, the optimal method and conditions of treatment are not known. In this preliminary study, we aimed to develop a cryoablation needle which can control the ablated area considering application through endoscopic ultrasonography. Methods: Here, we used a novel cryoneedle cooling system which can adjust the ablation range based on a liquid carbon dioxide refrigerant. Applied to the livers of swine, the cryoablation needle rapidly reached −60 °C within 30 s and cryoablation was performed for approximately 240 s. Based on the distance and depth, we collected real-time temperature data during the procedure. To compare the extent of cell death over time, tissue samples were collected hourly from 3 to 6 h after the procedure. Results: Approximately 4–5 mm of tissue was ablated via cryoablation, and cell death progressed over time after cryoablation. Moreover, the ablated lesions could be regulated using an insulating agent on the needle. Conclusions: This preliminary study on a novel surgical cooling needle system compatible with endoscopic ultrasound for cryoablation-based pancreatic cancer treatment confirmed the efficacy of cryoablation and identified the conditions necessary to induce necrosis. Additionally, this study evaluated the effectiveness of the insulation component of the system in protecting normal cells and assessed the extent of necrosis over time after the procedure.

Verified
Journal Article
Open access
PDF file
JLJonghyun Lee
Jonghyun Lee
SHSung Yong Han
Sung Yong Han
DBDong Hoon Baek
Dong Hoon Baek
Gwang Ha KimGwang Ha Kim
Gwang Ha Kim
GSGeun Am Song
Geun Am Song
DKDong Uk Kim
Dong Uk Kim
This study evaluated the prevalence and risk factors of early- (within 7 days of placement) and late-onset (after 7 days of placement) cholecystitis after Y-configured metal stent placement. Between June 2005 and August 2020, 109 patients who had been treated with Y-configured metal stents for malignant hilar obstruction were enrolled in the study. We retrospectively analyzed the potential risk factors for post-stent cholecystitis. The presence of diabetes (p = 0.042), the length of the common part of the Y-stent (p = 0.017), filling of the gallbladder with contrast medium during the procedure (p = 0.040), and tumor invasion of the cystic duct accompanied by filling the gallbladder with contrast medium during metal stent placement (p = 0.001) were identified as important risk factors. In cases of late-onset cholecystitis, stent obstruction (p = 0.004) and repeated endoscopic procedures due to stent malfunction (p = 0.024) were significant risk factors. In the multivariate logistic regression analysis, significant risk factors were the length of the common part of the Y-stent (p = 0.032) in early-onset cholecystitis and stent obstruction (p = 0.007) in late-onset cholecystitis. This study demonstrated that early-onset cholecystitis may occur in patients according to the length of the common portion of the Y-stent. In contrast, late-onset cholecystitis may occur in patients with stent obstruction.

31 July 2023 in The Korean Journal of Pancreas and Biliary Tract
Verified
Journal Article
Open access
PDF file
JLJonghyun Lee
Jonghyun Lee
DKDong Uk Kim
Dong Uk Kim
Cholangiocarcinoma (CCA) is one of the cancers with the worst prognosis. Its incidence and mortality have increased in recent years, but treatment options are limited. Although various clinical trials have been conducted, there is no effective therapeutic agent yet. As molecular genetic profiling is progressing in CCA, the interest in targeted therapies is growing. To realize targeted therapy in practice, various clinical requirements must be met. A molecular biological test should be performed on a patient’s tissue or blood, a target should be determined using an appropriate analysis method, and there should be a targeted agent. Regarding CCA, genetic variation occupies an intermediate level. Accordingly, many new agents have been recently developed for molecular biological targets. The most common genetic aberrations show almost similar patterns in intrahepatic and extrahepatic CCA. However, HER2 gene amplification is more often observed in extrahepatic CCA, and FGFR2 fusion, IDH1 mutation, and RAS-RAF-MEK-ERK signaling system mutations are more frequently found in intrahepatic CCA. Phase 2 or 3 clinical trials are being conducted with zanidatamab for HER2 amplification, pemigatinib/infigratinib for FGFR fusion, ivosidenib for IDH1 mutation, and dabrafenib for BRAFV600E mutation. In addition, clinical trials for agents targeting the NTRK, BRCA, and ARID1A gene mutations are ongoing. These targeted therapies are expected to have a bright future as a new treatment for CCA.

30 September 2024 in Clinical Endoscopy
Verified
Journal Article
Open access
현손현준 손
현준 손
JLJonghyun Lee
Jonghyun Lee
SHSung Yong Han
Sung Yong Han
TKTae In Kim
Tae In Kim
DKDong Uk Kim
Dong Uk Kim
GKGun-Ho Kim
Gun-Ho Kim
Background/Aims: Pancreatic cancer poses significant challenges due to its tendency for late-stage diagnosis and high mortality rates. Cryoablation, a technique used to treat various types of cancer, has shown potential in enhancing the prognosis of pancreatic cancer when combined with other therapies. However, its implementation is often limited by the need for lengthy procedures and specialized equipment. This study aims to develop a cryoablation needle optimized for endoscopic ultrasonography to simplify its application in treating pancreatic cancer.Methods: The study involved conducting cryoablation experiments on swine liver tissue. It utilized cryo-needles to evaluate the extent of cell death across various temperatures and durations of cryoablation.Results: The cryoablation system, which employed liquid carbon dioxide, achieved rapid cooling, reaching temperatures below –60 °C within 30 seconds and maintained the cryoablation process for 200 seconds. These conditions resulted in necrosis of the liver tissue. Notable cellular changes were observed up to 15 mm away from the cryoablation needle.Conclusions: This experimental study successfully demonstrated the efficacy of using a cryo-needle for cryoablation in swine liver tissue. Further trials involving pancreatic tissue are expected to verify its effectiveness, underscoring the importance of continued research to establish its role as a complementary therapy in pancreatic cancer treatment.