Hisham Elkadi

Prof. Hisham Elkadi


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2024 in Science of The Total Environment
Verified
Journal Article
Open access
Esraa ElmarakbyEsraa Elmarakby
Esraa Elmarakby
HEHisham Elkadi
Hisham Elkadi
The global climate is under threat from increasing extreme heat, evidenced by rising temperatures and a surge in hot days. Heat waves are intensifying worldwide, impacting cities and residents, as demonstrated by the record-breaking heat experienced in the UK in 2022, which resulted in over 4500 deaths. Urban heat islands (UHIs) exacerbate these heat waves, making city residents more vulnerable to heat-related deaths. UHIs occur when temperatures in urban areas exceed those in surrounding rural areas due to the heat-absorbing properties of urban structures. Implementing mitigation strategies, such as green infrastructure, is crucial for enhancing urban resilience and reducing vulnerability to UHIs. Effectively addressing UHIs requires a systematic approach, including developing risk maps to prioritise areas for UHI mitigation strategies. Using remote sensing, GIS, and SPSS correlational analysis, the research aims to develop and assess a Heat Risk Index (HRI). This index integrates UHI spatial intensity, current green cover, and population density at the district level to develop the risk index. This study stands out for its novel approach to developing the HRI, focusing on the localised impact of the UHI in Manchester City, identifying high-risk heat-vulnerable districts, and prioritising implementing effective UHI mitigation strategies. The findings highlight the importance of this approach, revealing that approximately 30 % of Manchester City is affected by UHI effects, with areas near the city centre, characterised by higher population density and reduced green cover, being particularly vulnerable. Furthermore, the study suggests that applying HRIs at a more localised level, such as the neighbourhood level rather than the district level, would provide more relevant and targeted insights for mitigating UHI. A more localised index would offer tailored insights into the unique conditions of each neighbourhood within the districts, enabling more effective mitigation strategies. The HRI developed in this paper serves as a test for a more nuanced and comprehensive index, considering additional variables related to population vulnerability and city urban structure.

6 December 2023 in Journal of Cleaner Production
Verified
Journal Article
Open access
Esraa ElmarakbyEsraa Elmarakby
Esraa Elmarakby
HEHisham Elkadi
Hisham Elkadi

1 November 2018 in Sustainable Cities and Society
Verified
Journal Article
Closed access
IKInji Kenawy
Inji Kenawy
HEHisham Elkadi
Hisham Elkadi

2 September 2022 in Building and Environment
Verified
Journal Article
Open access
MSMahsa Seifhashemi
Mahsa Seifhashemi
HEHisham Elkadi
Hisham Elkadi

24 April 2024 in Science of The Total Environment
Verified
Journal Article
Open access
Esraa ElmarakbyEsraa Elmarakby
Esraa Elmarakby
HEHisham Elkadi
Hisham Elkadi
In Transit-Oriented Development (TOD), the close integration of residential structures with community activities and traffic heightens residents' exposure to traffic-related pollutants. Despite traffic being a primary source of particulate matter (PM), the compact design of TODs, together with the impact of urban heat island (UHI), increases the likelihood of trapping emitted PM from traffic, leading to heightened exposure of TOD residents to PM. Although PM originates from two distinct sources in road traffic, exhaust and non-exhaust emissions (NEE), current legislation addressing traffic-related PM from non-exhaust emissions sources remains limited. This paper focuses on two TOD typologies in Manchester City-Manchester Piccadilly and East Didsbury-to understand the roles of TOD traffic as a PM generator and TOD place design as a PM container and trapper. The investigation aims to establish correlations between street design canyon ratios, vehicular Speed, and PM10/PM2.5, providing design guidance and effective traffic management strategies to control PM emissions within TODs. Through mapping the canyon ratio and utilising the Breezometer API for PM monitoring, the paper revealed elevated PM levels in both TOD areas, exceeding World Health Organization (WHO) recommendations, particularly for PM2.5. Correlation analysis between canyon configuration and PM2.5/PM10 highlighted the importance of considering building heights and avoiding the creation of deep canyons in TOD design to minimise the limited dispersion of PM. Leveraging UK road statistics and the PTV Group API for vehicle speed calculations, the paper studied the average speeds on the TOD roads concerning PM. Contrary to conventional assumption, the correlation analyses have revealed a noteworthy association shift between vehicular speed and PM concentrations. A positive correlation existed between speed increase and PM increases on arterial roads. However, a negative correlation emerged on main, collector, and local streets, indicating that PM levels rise for both PM10 and PM2.5 as Speed decreases. These findings challenge the traditional assumption that higher Speed leads to increased emissions, highlighting the potential impact of NEE on PM concentrations. This paper calls for thorough design considerations and traffic management strategies in TOD, especially in dense areas, considering building height, optimising traffic flow, and enhancing compromised air quality associated with vehicular emissions.

8 October 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
HEHisham Elkadi
Hisham Elkadi
MSMahsa Seifhashemi
Mahsa Seifhashemi
Rachel LauwerijssenRachel Lauwerijssen
Rachel Lauwerijssen
Urban green infrastructure (UGI) plays a vital role in mitigating climate change risks, including urban development-induced warming. The effective maintenance and monitoring of UGI are essential for detecting early signs of water stress and preventing potential fire hazards. Recent research shows that plants close their stomata under limited soil moisture availability, leading to an increase in leaf temperature. Multi-spectral cameras can detect thermal differentiation during periods of water stress and well-watered conditions. This paper examines the thermography of five characteristic green wall and green roof plant types (Pachysandra terminalis, Lonicera nit. Hohenheimer, Rubus tricolor, Liriope muscari Big Blue, and Hedera algeriensis Bellecour) under different levels of water stress compared to a well-watered reference group measured by thermal cameras. The experiment consists of a (1) pre-test experiment identifying the suitable number of days to create three different levels of water stress, and (2) the main experiment tested the suitability of thermal imaging with a drone to detect water stress in plants across three different dehydration stages. The thermal images were captured analyzed from three different types of green infrastructure. The method was suitable to detect temperature differences between plant types, between levels of water stress, and between GI types. The results show that leaf temperatures were approximately 1–3 °C warmer for water-stressed plants on the green walls, and around 3–6 °C warmer on the green roof compared to reference plants with differences among plant types. These insights are particularly relevant for UGI maintenance strategies and regulations, offering valuable information for sustainable urban planning.