Mikio Kozuma

Prof. Mikio Kozuma

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2022 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
YMYuki Miyazawa
Yuki Miyazawa
RIRyotaro Inoue
Ryotaro Inoue
HMHiroki Matsui
Hiroki Matsui
GNGyohei Nomura
Gyohei Nomura
MKMikio Kozuma
Mikio Kozuma
We report the realization of a Bose-Einstein condensate of europium atoms, which is a strongly dipolar species with unique properties, a highly symmetric [Xe]4f76s2 S7/28 electronic ground state and a hyperfine structure. By means of evaporative cooling in a crossed optical dipole trap, we produce a condensate of Eu151 containing up to 5×104 atoms. We estimate the scattering length of Eu151 to be as=110(4)  aB after comparing the velocities of expansion of condensates to different orientations of the atomic magnetic moments, where aB is the Bohr radius. We observe deformation of the condensate in the vicinity of the Feshbach resonance at 1.32 G with a width of 10 mG.

26 May 2021 in Physical Review A
Verified
Journal Article
Closed access
PDF file
YMYuki Miyazawa
Yuki Miyazawa
RIRyotaro Inoue
Ryotaro Inoue
HMHiroki Matsui
Hiroki Matsui
KTKenta Takanashi
Kenta Takanashi
MKMikio Kozuma
Mikio Kozuma
We report on the realization of a magneto-optical trap (MOT) for europium atoms using a narrow-line cooling transition with a natural linewidth of 97 kHz. Europium is a strongly dipolar species with interesting properties, such as the presence of hyperfine structure and the absence of electronic orbital angular momentum. Our starting point of the MOT is continuous capturing and cooling of optically pumped metastable europium atoms. We have employed simultaneous MOT for the metastable and ground-state atoms. The trapped metastable atoms are successively pumped back to the ground state and then continuously loaded to the narrow-line MOT, where up to 4.7×107 atoms are captured. A spin-polarized sample at a temperature of 6μK and with a peak number density of 2.2×1011cm−3 is obtained through the compression process, resulting in a phase space density of 3×10−5.

4 January 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
NTNobuyuki Takei
Nobuyuki Takei
MMMartin Miranda
Martin Miranda
YMYuki Miyazawa
Yuki Miyazawa
MKMikio Kozuma
Mikio Kozuma
The short-term sensitivity of a several-kilometers long fiber-optic gyroscope is limited mainly by thermal phase noise and relative intensity noise. Increasing the phase modulation frequency decreases the thermal phase noise but not the relative intensity noise since it behaves as white noise. Here, we propose and experimentally demonstrate that the angular random walk can be effectively decreased by suppressing relative intensity noise at the modulation frequency and its third-order harmonic using direct feedback to the drive current of a superluminescent diode. Our simultaneous suppression of thermal phase noise and relative intensity noise yields an angular random walk of 15 μdeg/ √h and a bias instability of 33 μdeg/h using a fiber coil with a length of 5 km and an effective area of 280 m 2 for a measurement time of 40 hours.

1 April 2025 in Physical Review Applied
Verified
Journal Article
Closed access
TSTomoya Sato
Tomoya Sato
NNNaoki Nishimura
Naoki Nishimura
NKNaoki Kaku
Naoki Kaku
SOSotatsu Otabe
Sotatsu Otabe
TKTakuya Kawasaki
Takuya Kawasaki
MKMikio Kozuma
Mikio Kozuma

1 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MMMartin Miranda
Martin Miranda
NTNobuyuki Takei
Nobuyuki Takei
YMYuki Miyazawa
Yuki Miyazawa
MKMikio Kozuma
Mikio Kozuma
Optimizing the bias modulation of a fiber-optic gyroscope is crucial to improving its precision. In this study, we propose and demonstrate the use of multiple harmonics of sinusoidal modulation as an intermediate alternative to the widely used modulation methods: sinusoidal and square-wave modulation. We show that this alternative integrates the advantages of each modulation method by providing a smooth modulation that produces a clean, spike-free output and a satisfactory signal-to-noise ratio. By using three harmonics of modulation in combination with a high frequency to reduce thermal phase noise, we obtained an angular random walk of 5.2(2)μdeg/h and a bias instability of ∼10μdeg/h. This is the highest performance ever reported for fiber-optic gyroscopes.

7 October 2022 in Optics Communications
Verified
Journal Article
Closed access
THToshiyuki Hosoya
Toshiyuki Hosoya
RIRyotaro Inoue
Ryotaro Inoue
TSTomoya Sato
Tomoya Sato
MKMikio Kozuma
Mikio Kozuma