Luis Paulo Brasil de Souza

Dr. Luis Paulo Brasil de Souza

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2023 in Geoenergy Science and Engineering
Verified
Journal Article
Closed access
LSLuis Paulo Brasil de Souza
Luis Paulo Brasil de Souza
GFGuilherme Rezende Bessa Ferreira
Guilherme Rezende Bessa Ferreira
ICIsabel Camerini
Isabel Camerini
TCTiago de Magalhães Correia
Tiago de Magalhães Correia
MRMateus Gheorghe de Castro Ribeiro
Mateus Gheorghe de Castro Ribeiro
JBJoão Humberto Guandalini Batista
João Humberto Guandalini Batista

1 January 2023 in Matéria (Rio de Janeiro)
Verified
Journal Article
Open access
PDF file
LSLuis Paulo Brasil de Souza
Luis Paulo Brasil de Souza
DPDario Prada Parra
Dario Prada Parra
JRJosé Alan Foicinha Raiol
José Alan Foicinha Raiol
ABArthur Braga
Arthur Braga
LRLeonardo Dantas Rodrigues
Leonardo Dantas Rodrigues
The loads acting on mechanical components are usually complex, and the more traditional fatigue analysis criteria may be non-conservative, especially in out-of-phase and non-proportional loadings. Many multiaxial fatigue models have been developed and need to be experimentally validated. This work describes the load control mechanism of a low-cost electromechanical multiaxial fatigue testing machine, which applies variable axial and torsional loads. A load cell interconnected to the motor control system was manufactured and instrumented with extensometers. For the axial load, a four-bar mechanism coupled to a power screw was designed to apply alternating axial loads, thus ensuring a higher load frequency and preservation of the motor, which will not need to alternate its direction of rotation. The machine’s control system, focused on out-phase loading, is based on the data sent by the load cell and pulse encoders per degree for each motor, ensuring good accuracy in applied loads. Tests were carried out to check the system’s response, in which it was possible to apply load curves of torque and axial force in different phase shift angle. Therefore, several existing multiaxial fatigue models can be tested with good reliability.

31 December 2024 in Wave Motion
Verified
Journal Article
Closed access
LSLuis Paulo Brasil de Souza
Luis Paulo Brasil de Souza
JHJuan Andrés Santisteban Hidalgo
Juan Andrés Santisteban Hidalgo
TCTiago de Magalhães Correia
Tiago de Magalhães Correia
ICIsabel Camerini
Isabel Camerini
GFGuilherme Rezende Bessa Ferreira
Guilherme Rezende Bessa Ferreira
ABArthur Braga
Arthur Braga

1 December 2020 in Rio Oil and Gas Expo and Conference
Verified
Journal Article
Closed access
RARafael Valladares De Almeida
Rafael Valladares De Almeida
TCTiago de Magalhães Correia
Tiago de Magalhães Correia
JHJuan Andres Santisteban Hidalgo
Juan Andres Santisteban Hidalgo
ICIsabel Camerini
Isabel Camerini
BSBruno Greco De Sousa
Bruno Greco De Sousa
LSLuis Paulo Brasil de Souza
Luis Paulo Brasil de Souza

28 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ICIsabel Camerini
Isabel Camerini
LSLuis Paulo Brasil de Souza
Luis Paulo Brasil de Souza
PGPaula Gouvêa
Paula Gouvêa
ABArthur Braga
Arthur Braga
Acoustic waves can be used for wireless telemetry as an alternative to situations where electrical or optical penetrators are unsuitable. However, the response of the ultrasonic transducer can be greatly affected by temperature variations, mechanical deformations, misalignment between transducers, and multiple layers in the propagation zone. Therefore, this work sought to quantify such influences on communication between ultrasonic transducers. The experimental measurements were performed at the frequency where power transfer is maximized. Moreover, there were four experimental models, each with its own performed setup. The ultrasonic transducers are attached to both sides of a 6 mm thick stainless-steel plate for configuring just one barrier. Multiple layers of transducers are attached to the outer side of two plates immersed in an acoustic fluid with a 100 mm thick barrier. In both cases, the S21 parameter was used to quantify the influence of the physical barrier because it correlates with the power flow between ports that return after a given excitation. The results showed that when a maximum deformation of 1250 μm/m was applied, the amplitude of the S21 parameter varied around +0.7 dB. Furthermore, increasing the temperature from 30 to 100 °C slightly affected the S21 (+0.8 dB), but the signal decayed quickly for temperatures beyond 100 °C. Additionally, the ultrasonic communication with a multiple layer was found to occur under misalignment with an intersection area of up to 40%. None of the factors evaluated resulted in insufficient power transfer, except for a large misalignment between the transducers. Such results indicate that this type of communication can be a robust alternative, with a minimum alignment of 40% between transducers and electrical penetrators.

3 May 2024 in Geoenergy Science and Engineering
Verified
Journal Article
Closed access
TCTiago de Magalhães Correia
Tiago de Magalhães Correia
LSLuis Paulo Brasil de Souza
Luis Paulo Brasil de Souza
GFGuilherme Rezende Bessa Ferreira
Guilherme Rezende Bessa Ferreira
ICIsabel Camerini
Isabel Camerini
JHJuan Andrés Santisteban Hidalgo
Juan Andrés Santisteban Hidalgo
LSLuisa Nogueira de Azeredo Coutinho Soares
Luisa Nogueira de Azeredo Coutinho Soares