Masaya Nakatani

Mr. Masaya Nakatani


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2020 in IEEE Sensors Journal
Verified
Journal Article
Open access
RYRui Yatabe
Rui Yatabe
ASAtsushi Shunori
Atsushi Shunori
BWBartosz Wyszynski
Bartosz Wyszynski
YHYosuke Hanai
Yosuke Hanai
ANAtsuo Nakao
Atsuo Nakao
Kiyoshi TokoKiyoshi Toko
Kiyoshi Toko
In this study, we developed an odor sensor system using chemosensitive resistors, which outputted multichannel data. Mixtures of gas chromatography stationary materials (GC materials) and carbon black were used as the chemosensitive resistors. The interaction between the chemosensitive resistors and gas species shifted the electrical resistance of the resistors. Sixteen different chemosensitive resistors were fabricated on an odor sensor chip. In addition, a compact measurement instrument was fabricated. Sixteen channel data were obtained from the measurements of gas species using the instrument. The data were analyzed using machine learning algorithms available on Weka software. As a result, the sensor system successfully identified alcoholic beverages. Finally, we demonstrated the classification of restroom odor in a field test. The classification was successful with an accuracy of 97.9%.

11 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
BWBartosz Wyszynski
Bartosz Wyszynski
RYRui Yatabe
Rui Yatabe
ANAtsuo Nakao
Atsuo Nakao
MNMasaya Nakatani
Masaya Nakatani
AOAkio OKI
Akio OKI
Kiyoshi TokoKiyoshi Toko
Kiyoshi Toko
Mimicking the biological olfaction, large odor-sensor arrays can be used to acquire a broad range of chemical information, with a potentially high degree of redundancy, to allow for enhanced control over the sensitivity and selectivity of artificial olfaction systems. The arrays should consist of the largest possible number of individual sensing elements while being miniaturized. Chemosensitive resistors are one of the sensing platforms that have a potential to satisfy these two conditions. In this work we test viability of fabricating a 16-element chemosensitive resistor array for detection and recognition of volatile organic compounds (VOCs). The sensors were fabricated using blends of carbon black and gas chromatography (GC) stationary-phase materials preselected based on their sorption properties. Blends of the selected GC materials with carbon black particles were subsequently coated over chemosensitive resistor devices and the resulting sensors/arrays evaluated in exposure experiments against vapors of pyrrole, benzenal, nonanal, and 2-phenethylamine at 150, 300, 450, and 900 ppb. Responses of the fabricated 16-element array were stable and differed for each individual odorant sample, proving the blends of GC materials with carbon black particles can be effectively used for fabrication of large odor-sensing arrays based on chemosensitive resistors. The obtained results suggest that the proposed sensing devices could be effective in discriminating odor/vapor samples at the sub-ppm level.