Rui Yatabe

Rui Yatabe


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2017 in Sensors
Verified
Journal Article
Open access
PDF file
CLChuanjun Liu
Chuanjun Liu
BWBartosz Wyszynski
Bartosz Wyszynski
RYRui Yatabe
Rui Yatabe
KHKenshi Hayashi
Kenshi Hayashi
Kiyoshi TokoKiyoshi Toko
Kiyoshi Toko
The detection and recognition of metabolically derived aldehydes, which have been identified as important products of oxidative stress and biomarkers of cancers; are considered as an effective approach for early cancer detection as well as health status monitoring. Quartz crystal microbalance (QCM) sensor arrays based on molecularly imprinted sol-gel (MISG) materials were developed in this work for highly sensitive detection and highly selective recognition of typical aldehyde vapors including hexanal (HAL); nonanal (NAL) and bezaldehyde (BAL). The MISGs were prepared by a sol-gel procedure using two matrix precursors: tetraethyl orthosilicate (TEOS) and tetrabutoxytitanium (TBOT). Aminopropyltriethoxysilane (APT); diethylaminopropyltrimethoxysilane (EAP) and trimethoxy-phenylsilane (TMP) were added as functional monomers to adjust the imprinting effect of the matrix. Hexanoic acid (HA); nonanoic acid (NA) and benzoic acid (BA) were used as psuedotemplates in view of their analogous structure to the target molecules as well as the strong hydrogen-bonding interaction with the matrix. Totally 13 types of MISGs with different components were prepared and coated on QCM electrodes by spin coating. Their sensing characters towards the three aldehyde vapors with different concentrations were investigated qualitatively. The results demonstrated that the response of individual sensors to each target strongly depended on the matrix precursors; functional monomers and template molecules. An optimization of the 13 MISG materials was carried out based on statistical analysis such as principle component analysis (PCA); multivariate analysis of covariance (MANCOVA) and hierarchical cluster analysis (HCA). The optimized sensor array consisting of five channels showed a high discrimination ability on the aldehyde vapors; which was confirmed by quantitative comparison with a randomly selected array. It was suggested that both the molecularly imprinting (MIP) effect and the matrix effect contributed to the sensitivity and selectivity of the optimized sensor array. The developed MISGs were expected to be promising materials for the detection and recognition of volatile aldehydes contained in exhaled breath or human body odor.

4 September 2015 in Sensors
Verified
Journal Article
Open access
PDF file
RYRui Yatabe
Rui Yatabe
JNJunpei Noda
Junpei Noda
Yusuke TaharaYusuke Tahara
Yusuke Tahara
YNYoshinobu Naito
Yoshinobu Naito
HIHidekazu Ikezaki
Hidekazu Ikezaki
Kiyoshi TokoKiyoshi Toko
Kiyoshi Toko
It is possible to evaluate the taste of foods or medicines using a taste sensor. The taste sensor converts information on taste into an electrical signal using several lipid/polymer membranes. A lipid/polymer membrane for bitterness sensing can evaluate aftertaste after immersion in monosodium glutamate (MSG), which is called “preconditioning”. However, we have not yet analyzed the change in the surface structure of the membrane as a result of preconditioning. Thus, we analyzed the change in the surface by performing contact angle and surface zeta potential measurements, Fourier transform infrared spectroscopy (FTIR), X-ray photon spectroscopy (XPS) and gas cluster ion beam time-of-flight secondary ion mass spectrometry (GCIB-TOF-SIMS). After preconditioning, the concentrations of MSG and tetradodecylammonium bromide (TDAB), contained in the lipid membrane were found to be higher in the surface region than in the bulk region. The effect of preconditioning was revealed by the above analysis methods.

19 July 2013 in Sensors
Verified
Journal Article
Open access
PDF file
RYRui Yatabe
Rui Yatabe
TOTakeshi Onodera
Takeshi Onodera
Kiyoshi TokoKiyoshi Toko
Kiyoshi Toko
In this study, we modified a surface plasmon resonance immunosensor chip with a polymer using surface-initiated atom transfer polymerization (SI-ATRP) for the highly sensitive detection of 2,4,6-trinitrotoluene (TNT). To immobilize a TNT analogue on the polymer, mono-2-(methacryloyloxy)ethylsuccinate (MES), which has a carboxyl group, was used in this study. However, the anti-TNT antibody may adsorb non-specifically on the polymer surface by an electrostatic interaction because MES is negatively charged. Therefore, a mixed monomer with MES and diethylaminoethylmethacrylate (DEAEM), which has a tertiary amino group and is positively charged, was prepared to obtain electroneutrality for suppressing the nonspecific adsorption. The detection of TNT was performed by inhibition assay using the polymer surface. To ensure high sensitivity to TNT, the affinity between the surface and the antibody was optimized by controlling the density of the initiator for ATRP by mixing two types of self-assembled monolayer reagents. As a result, a limit of detection of 5.7 pg/mL (ppt) for TNT was achieved using the optimized surface.

14 August 2020 in IEEE Sensors Journal
Verified
Journal Article
Open access
RYRui Yatabe
Rui Yatabe
ASAtsushi Shunori
Atsushi Shunori
BWBartosz Wyszynski
Bartosz Wyszynski
YHYosuke Hanai
Yosuke Hanai
ANAtsuo Nakao
Atsuo Nakao
Kiyoshi TokoKiyoshi Toko
Kiyoshi Toko
In this study, we developed an odor sensor system using chemosensitive resistors, which outputted multichannel data. Mixtures of gas chromatography stationary materials (GC materials) and carbon black were used as the chemosensitive resistors. The interaction between the chemosensitive resistors and gas species shifted the electrical resistance of the resistors. Sixteen different chemosensitive resistors were fabricated on an odor sensor chip. In addition, a compact measurement instrument was fabricated. Sixteen channel data were obtained from the measurements of gas species using the instrument. The data were analyzed using machine learning algorithms available on Weka software. As a result, the sensor system successfully identified alcoholic beverages. Finally, we demonstrated the classification of restroom odor in a field test. The classification was successful with an accuracy of 97.9%.

11 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
BWBartosz Wyszynski
Bartosz Wyszynski
RYRui Yatabe
Rui Yatabe
ANAtsuo Nakao
Atsuo Nakao
MNMasaya Nakatani
Masaya Nakatani
AOAkio OKI
Akio OKI
Kiyoshi TokoKiyoshi Toko
Kiyoshi Toko
Mimicking the biological olfaction, large odor-sensor arrays can be used to acquire a broad range of chemical information, with a potentially high degree of redundancy, to allow for enhanced control over the sensitivity and selectivity of artificial olfaction systems. The arrays should consist of the largest possible number of individual sensing elements while being miniaturized. Chemosensitive resistors are one of the sensing platforms that have a potential to satisfy these two conditions. In this work we test viability of fabricating a 16-element chemosensitive resistor array for detection and recognition of volatile organic compounds (VOCs). The sensors were fabricated using blends of carbon black and gas chromatography (GC) stationary-phase materials preselected based on their sorption properties. Blends of the selected GC materials with carbon black particles were subsequently coated over chemosensitive resistor devices and the resulting sensors/arrays evaluated in exposure experiments against vapors of pyrrole, benzenal, nonanal, and 2-phenethylamine at 150, 300, 450, and 900 ppb. Responses of the fabricated 16-element array were stable and differed for each individual odorant sample, proving the blends of GC materials with carbon black particles can be effectively used for fabrication of large odor-sensing arrays based on chemosensitive resistors. The obtained results suggest that the proposed sensing devices could be effective in discriminating odor/vapor samples at the sub-ppm level.

15 February 2016 in Sensors
Verified
Journal Article
Open access
PDF file
YHYuhei Harada
Yuhei Harada
JNJunpei Noda
Junpei Noda
RYRui Yatabe
Rui Yatabe
HIHidekazu Ikezaki
Hidekazu Ikezaki
Kiyoshi TokoKiyoshi Toko
Kiyoshi Toko
A taste sensor that uses lipid/polymer membranes can evaluate aftertastes felt by humans using Change in membrane Potential caused by Adsorption (CPA) measurements. The sensor membrane for evaluating bitterness, which is caused by acidic bitter substances such as iso-alpha acid contained in beer, needs an immersion process in monosodium glutamate (MSG) solution, called “MSG preconditioning”. However, what happens to the lipid/polymer membrane during MSG preconditioning is not clear. Therefore, we carried out three experiments to investigate the changes in the lipid/polymer membrane caused by the MSG preconditioning, i.e., measurements of the taste sensor, measurements of the amount of the bitterness substance adsorbed onto the membrane and measurements of the contact angle of the membrane surface. The CPA values increased as the preconditioning process progressed, and became stable after 3 d of preconditioning. The response potentials to the reference solution showed the same tendency of the CPA value change during the preconditioning period. The contact angle of the lipid/polymer membrane surface decreased after 7 d of MSG preconditioning; in short, the surface of the lipid/polymer membrane became hydrophilic during MSG preconditioning. The amount of adsorbed iso-alpha acid was increased until 5 d preconditioning, and then it decreased. In this study, we revealed that the CPA values increased with the progress of MSG preconditioning in spite of the decrease of the amount of iso-alpha acid adsorbed onto the lipid/polymer membrane, and it was indicated that the CPA values increase because the sensor sensitivity was improved by the MSG preconditioning.