Valery Dolgashev

Dr. Valery Dolgashev

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2014 in Physical Review Special Topics - Accelerators and Beams
Verified
Journal Article
Open access
PDF file
VDValery Dolgashev
Valery Dolgashev
GBGordon Bowden
Gordon Bowden
YDYuantao Ding
Yuantao Ding
PEPaul Emma
Paul Emma
PKPatrick Krejcik
Patrick Krejcik
DXDao Xiang
Dao Xiang
Performance of the x-ray free electron laser Linac Coherent Light Source (LCLS) and the Facility for Advanced Accelerator Experimental Tests (FACET) is determined by the properties of their extremely short electron bunches. Multi-GeV electron bunches in both LCLS and FACET are less than 100 fs long. Optimization of beam properties and understanding of free-electron laser operation require electron beam diagnostics with time resolution of about 10 fs. We designed, built and commissioned a set of high frequency X-band deflectors which can measure the beam longitudinal space charge distribution and slice energy spread to better than 10 fs resolution at full LCLS energy (14 GeV), and with 70 fs resolution at full FACET energy (20 GeV). Use of high frequency and high gradient in these devices allows them to reach unprecedented performance. We report on the physics motivation, design considerations, operational configuration, cold tests, and typical results of the X-band deflector systems currently in use at SLAC.

21 March 2019 in Physical Review Applied
Verified
Journal Article
Open access
PDF file
SKSergey V Kutsaev
Sergey V Kutsaev
BJB. Jacobson
B. Jacobson
ASA.Yu. Smirnov
A.Yu. Smirnov
TCT. Campese
T. Campese
VDValery Dolgashev
Valery Dolgashev
SSS.C. Schaub
S.C. Schaub
The development of alternative mm-wave high-gradient, >200 MV/m, accelerating structures offers a promising path to reduce the cost and footprint of future TeV-scale linear colliders, as well as linacs for industrial, medical, and security applications. The major factor limiting accelerating gradient is vacuum rf breakdown. The probability of such breakdowns increases with pulse length. For reliable operation, millimeter-wave structures require nanoseconds-long pulses at the megawatt level. This power is available from gyrotrons, which have a minimum pulse length on the order of microseconds. To create shorter pulses and to reliably detect rf breakdowns, we developed the following devices: a laser-based rf switch capable of selecting 10 ns long pulses out of the microseconds long gyrotron pulses, thus enabling the use of the gyrotrons as power sources for mm-wave high-gradient linacs, and a shot-to-shot sub-THz spectrometer with high-frequency resolution, capable of detecting pulse shortening due to rf breakdowns. We will describe the principle of operation of these devices and their achieved parameters. We also report on the experimental demonstration of these devices with the high-power gyrotron at the Massachusetts Institute of Technology. In the experiments, we demonstrate nanosecond rf power modulation, shot-to-shot measurements of the pulse spectra, and detection of rf breakdowns.

15 January 2010 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
CJChunguang Jing
Chunguang Jing
WGWei Gai
Wei Gai
JPJohn G. Power
John G. Power
RKRichard Konecny
Richard Konecny
WLWanming Liu
Wanming Liu
AKAlexei Kanareykin
Alexei Kanareykin
We summarize recent progress in a program to develop externally powered dielectric-loaded accelerating (DLA) structures that can sustain high accelerating gradients. High-power RF tests of earlier structures showed strong multipactor loading. In addition, arcing at dielectric joints between the uniform DLA structure and matching sections at either end limited the achievable gradient. In this paper, we study the onset of multipactor in a DLA structure. We also study the effect of thin-film TiN coatings applied by atomic layer deposition and the effect of a reduction in the inner diameter of the structure. Test results of these structures show significant decreases in multipactor loading. We also test new structure designs that eliminate separate dielectric matching sections and, thus, the requirement for dielectric joints, including a DLA structure using a coaxial coupler and a clamped DLA structure. The clamped structure demonstrated a significantly improved gradient without breakdown.

10 August 2021 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
VDValery Dolgashev
Valery Dolgashev
LFLuigi Faillace
Luigi Faillace
BSBruno Spataro
Bruno Spataro
STS. Tantawi
S. Tantawi
RBR. Bonifazi
R. Bonifazi
Linacs for high-energy physics, as well as for industry and medicine, require accelerating structures which are compact, robust, and cost-effective. Small foot-print linacs require high-accelerating gradients. Currently, stable-operating gradients, exceeding 100  MV/m, have been demonstrated at SLAC National Accelerator Laboratory, CERN, and KEK at X-band frequencies. Recent experiments show that accelerating cavities made out of hard copper alloys achieve better high-gradient performance as compared with soft copper cavities. In the scope of a decade-long collaboration between SLAC, INFN-Frascati, and KEK on the development of innovative high-gradient structures, this particular study focuses on the technological developments directed to show the viability of novel welding techniques. Two novel X-band accelerating structures, made out of hard copper, were fabricated at INFN-Frascati by means of clamping and welding. One cavity was welded with the electron beam and the other one with the tungsten inert gas welding process. In the technological development of the construction methods of high-gradient accelerating structures, high-power testing is a critical step for the verification of their viability. Here, we present the outcome of this step—the results of the high-power rf tests of these two structures. These tests include the measurements of the breakdown rate probability used to characterize the behavior of vacuum rf breakdowns, one of the major factors limiting the operating accelerating gradients. The electron beam welded structure demonstrated accelerating gradients of 90  MV/m at a breakdown rate of 10−3/(pulse meter) using a shaped pulse with a 150 ns flat part. Nevertheless, it did not achieve its ultimate performance because of arcing in the mode launcher power coupler. On the other hand, the tungsten inert gas welded structure reached its ultimate performance and operated at about a 150  MV/m gradient at a breakdown rate of 10−3/(pulse meter) using a shaped pulse with a 150 ns flat part. The results of both experiments show that welding, a robust, and low-cost alternative to brazing or diffusion bonding, is viable for high-gradient operation. This approach enables the construction of multicell standing and traveling-wave accelerating structures.

19 December 2022 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
MSMitchell Schneider
Mitchell Schneider
VDValery Dolgashev
Valery Dolgashev
JLJohn W. Lewellen
John W. Lewellen
STSami G. Tantawi
Sami G. Tantawi
ENEmilio Nanni
Emilio Nanni
ESEvgenya Simakov
Evgenya Simakov
We report the high gradient testing results of two single-cell off-axis coupled standing wave accelerating structures. Two brazed standing wave off-axis coupled structures with the same geometry were tested: one made of pure copper (Cu) and one made of a copper–silver (CuAg) alloy with a silver concentration of 0.08%. A peak surface electric field of 450 MV/m was achieved in the CuAg structure for a klystron input power of 14.5 MW and a 1 μs pulse length, which was 25% higher than the peak surface electric field achieved in the Cu structure. The superb high gradient performance was achieved because of the two major optimizations in the cavity's geometry: (1) the shunt impedance of the cavity was maximized for a peak surface electric field to accelerating gradient ratio of ∼2 for a fully relativistic particle, and (2) the peak magnetic field enhancement due to the input coupler was minimized to limit pulse heating. These tests allow us to conclude that C-band accelerating structures can operate at peak fields similar to those at higher frequencies while providing a larger beam iris for improved beam transport.

29 September 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VDValery Dolgashev
Valery Dolgashev
This article will review methods used at the SLAC National Accelerator Laboratory and other world accelerator laboratories to design high-gradient normal conducting accelerating structures. A quest for compact radio-frequency linacs fueled decades of studies toward a higher accelerating gradient. A major phenomena limiting the increase of the gradient is vacuum radio-frequency breakdown; therefore, this paper will address the breakdown physics and discuss approaches that reduce the breakdown probability. This discussion will cover both the electrical design and fabrication technology of the accelerating structures to achieve practical operating accelerating gradients in excess of 100 MV/m. Most of the data described here were obtained during the development of 11 GHz linacs for electron–positron linear colliders, so extrapolation of the results to other frequencies should be performed cautiously.