A sensor suitable for online monitoring of viscosity and density of glycerol–water mixtures is presented. The device is based on Lorentz force excitation and features an integrated piezoresistive readout. The core sensing element is a rectangular vibrating plate suspended by four beam springs. Two of the plate-carrying springs comprise piezoresistors. With two additional resistors on the silicon rim they form a half Wheatstone-bridge. Through the conductive layer of the beam springs a sinusoidal excitation current is driven. In the field of a permanent magnet, the Lorentz force excites plate vibrations resulting in a bridge unbalance. We recorded both the frequency response of the amplitude and the phase of the bridge output. By evaluating the properties of the resonant system, it is possible to extract the glycerol percentage and, hence, the viscosity and the mass density of the mixtures.
10 July 2013 in Measurement Science and Technology
We report on simulation-based sensor design and measurement results of a bidirectional micromachined hot-film anemometer. The device is based on a thin-film thermistor made of amorphous germanium embedded in a silicon nitride membrane. The germanium structure is divided by metal-strip electrodes into four thermistor segments which are connected to a Wheatstone bridge. The sensor combines hot-film and calorimetric transduction principles. The flow dependent cooling of the hot film results in a unipolar, strictly monotonic transduction characteristic which is utilized for flow velocity measurements. Moreover, convective heat transfer between the hot-film segments causes thermal asymmetry yielding a bridge detuning voltage with a bipolar characteristic where its sign corresponds to the flow direction. Consequently, the sensor features a strictly monotonic transduction characteristic over a wide flow velocity range combined with simultaneous detection of the flow direction. The device was characterized in constant-current and constant-temperature operating modes for stationary flows as well as step-like changes of the flow velocity. The sensor behaviour as a result of ambient temperature variations was studied in detail.
We present a novel transient measurement method to characterize effective values of the thermal conductivity, thermal diffusivity, and emissivity of a thin-film membrane implemented in a micromachined multiparameter wind sensor. Accurate values for these parameters are mandatory as they considerably influence the thermal heat shunt induced by the membrane, which is the main limiting factor for reliable sensor operation in gases with low thermal admittance and thus determines the ultimate device sensitivity. Compared with commonly used measurement techniques for these thermal thin-film parameters, our method does not require custom-built specimens, i.e., the results can directly be obtained from transient excess temperature measurements on the wind sensor device utilizing the embedded thin-film heater and thermistors. The presented method as such is universal and can easily be applied to other configurations of heating and temperature sensing elements placed on a circular thin-film membrane. In this contribution, we describe the theoretical background of this method, provide an efficient semianalytical model for the data evaluation including its validation by computer numerical simulations, and showcase sample measurements on multilayer Si x N y -SiO 2 thin films.
A 2D calorimetric flow transducer is used to study distortions of the flow velocity field induced by small surface discontinuities around the chip. The transducer is incorporated into a matching recess of a PCB enabling wire-bonded interconnections to the transducer. The chip mount forms one wall of a rectangular duct. Two shallow recesses at opposite edges of the transducer chip are required for wired interconnections. They distort the flow velocity field inside the duct and deteriorate the flow setting precision. In-depth 3D-FEM analyses of the setup revealed that both the local flow direction as well as the surface-near distribution of the flow velocity magnitude deviate significantly from the ideal guided flow case. With a temporary leveling of the indentations, the impact of the surface imperfections could be largely suppressed. Including a yaw setting uncertainty of about ±0.5°, a peak-to-peak deviation of 3.8° of the transducer output from the intended flow direction was achieved with a mean flow velocity of 5 m/s in the duct corresponding to a shear rate of 2.4·104 s−1 at the chip surface. In view of the practical compromises, the measured deviation compares well with the peak-to-peak value of 1.74° predicted by previous simulations.