Donghwan Lee

Dr. Donghwan Lee


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2019 in Diagnostics
Verified
Journal Article
Open access
PDF file
Minh Tri NgoMinh Tri Ngo
Minh Tri Ngo
CKChul In Kim
Chul In Kim
JJJinmu Jung
Jinmu Jung
GCGyung Ho Chung
Gyung Ho Chung
DLDonghwan Lee
Donghwan Lee
HKHyo Sung Kwak
Hyo Sung Kwak
Purpose: Knowledge of the hemodynamics in the vascular system is important to understand and treat vascular pathology. The present study aimed to evaluate the hemodynamics in the human carotid artery bifurcation measured by four-dimensional (4D) flow magnetic resonance imaging (MRI) as compared to computational fluid dynamics (CFD). Methods: This protocol used MRI data of 12 healthy volunteers for the 3D vascular models and 4D flow MRI measurements for the boundary conditions in CFD simulation. We compared the velocities measured at the carotid bifurcation and the 3D velocity streamlines of the carotid arteries obtained by these two methods. Results: There was a good agreement for both maximum and minimum velocity values between the 2 methods for velocity magnitude at the bifurcation plane. However, on the 3D blood flow visualization, secondary flows, and recirculation regions are of poorer quality when visualized through the 4D flow MRI. Conclusion: 4D flow MRI and CFD show reasonable agreement in demonstrated velocity magnitudes at the carotid artery bifurcation. However, the visualization of blood flow at the recirculation regions and the assessment of secondary flow characteristics should be enhanced for the use of 4D flow MRI in clinical situations.

1 November 2018 in Journal of Korean Neurosurgical Society
Verified
Journal Article
Open access
PDF file
ULUi Yun Lee
Ui Yun Lee
JJJinmu Jung
Jinmu Jung
HKHyo Sung Kwak
Hyo Sung Kwak
DLDonghwan Lee
Donghwan Lee
GCGyung Ho Chung
Gyung Ho Chung
EKEun Jeong Koh
Eun Jeong Koh
The goal of this study was to compare several parameters, including wall shear stress (WSS) and flow pattern, between unruptured and ruptured anterior communicating artery (ACoA) aneurysms using patient-specific aneurysm geometry. In total, 18 unruptured and 24 ruptured aneurysms were analyzed using computational fluid dynamics (CFD) models. Minimal, average, and maximal wall shear stress were calculated based on CFD simulations. Aneurysm height, ostium diameter, aspect ratio, and area of aneurysm were measured. Aneurysms were classified according to flow complexity (simple or complex) and inflow jet (concentrated or diffused). Statistical analyses were performed to ascertain differences between the aneurysm groups. Average wall shear stress of the ruptured group was greater than that of the unruptured group (9.42% for aneurysm and 10.38% for ostium). The average area of ruptured aneurysms was 31.22% larger than unruptured aneurysms. Simple flow was observed in 14 of 18 (78%) unruptured aneurysms, while all ruptured aneurysms had complex flow (p<0.001). Ruptured aneurysms were more likely to have a concentrated inflow jet (63%), while unruptured aneurysms predominantly had a diffused inflow jet (83%, p=0.004). Ruptured aneurysms tended to have a larger geometric size and greater WSS compared to unruptured aneurysms, but the difference was not statistically significant. Flow complexity and inflow jet were significantly different between unruptured and ruptured ACoA aneurysms.

16 December 2023 in Life
Verified
Journal Article
Open access
PDF file
JKJunyoung Kim
Junyoung Kim
DLDonghwan Lee
Donghwan Lee
Klebsiella pneumoniae (K. pneumoniae) is a multidrug-resistance Gram-negative organism responsible for carbapenem-resistant infections. These challenges have inspired studies on the use of natural products as alternatives to conventional drugs. The aim of this study was to analyze the antibacterial and antioxidant effects of Ficus carica L. (fig) branch extracts and to perform in vivo animal experiments to better understand the absorption mechanisms of the antibacterial components during the digestion process after oral administration. The antibacterial components of the fig branch extracts were analyzed via gas chromatography-mass spectrometry (GC-MS). An in vivo animal study and liquid chromatography-triple quadrupole-tandem mass spectrometry (LC-QQQ-MS/MS) analyses were performed to analyze the deacetylation reactions of the fig extracts after oral administration in mice. Ultimately, the antibacterial effects of the fig extracts increased with the fractional distillation time. The fig extracts showed excellent antibacterial effects against K. pneumoniae, as well as Escherichia coli (E. coli), Staphylococcus aureus (S. aureus), and Pseudomonas aeruginosa (P. aeruginosa). The three antibacterial and antioxidant components of the fig extracts were revealed to be eugenol, acetyleugenol, and psoralen. Interestingly, in this study, we identified acetyleugenol in the phenolic compounds of the fig extract for the first time. Through in vivo animal testing, we observed the deacetylation reaction of acetyleugenol to eugenol in the fig extract as digestion proceeded in the internal organs of the mice after oral administration. The results of this study suggest the use of natural fig extract as an effective therapeutic and prophylactic antibacterial agent for inflammation-related infections with a wide variety of biomedical applications.

13 October 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Minh Tri NgoMinh Tri Ngo
Minh Tri Ngo
ULUi Yun Lee
Ui Yun Lee
HHHojin Ha
Hojin Ha
JJJinmu Jung
Jinmu Jung
DLDonghwan Lee
Donghwan Lee
HKHyo Sung Kwak
Hyo Sung Kwak
Assessment of carotid bulb hemodynamics using four-dimensional (4D) flow magnetic resonance imaging (MRI) requires accurate segmentation of recirculation regions that is frequently hampered by limited resolution. This study aims to improve the accuracy of 4D flow MRI carotid bulb segmentation and subsequent recirculation regions analysis. Time-of-flight (TOF) MRI and 4D flow MRI were performed on bilateral carotid artery bifurcations in seven healthy volunteers. TOF-MRI data was segmented into 3D geometry for computational fluid dynamics (CFD) simulations. ITK-SNAP segmentation software was included in the workflow for the semi-automatic generation of 4D flow MRI angiographic data. This study compared the velocities calculated at the carotid bifurcations and the 3D blood flow visualization at the carotid bulbs obtained by 4D flow MRI and CFD. By applying ITK-SNAP segmentation software, an obvious improvement in the 4D flow MRI visualization of the recirculation regions was observed. The 4D flow MRI images of the recirculation flow characteristics of the carotid artery bulbs coincided with the CFD. A reasonable agreement was found in terms of velocity calculated at the carotid bifurcation between CFD and 4D flow MRI. However, the dispersion of velocity data points relative to the local errors of measurement in 4D flow MRI remains. Our proposed strategy showed the feasibility of improving recirculation regions segmentation and the potential for reliable blood flow visualization in 4D flow MRI. However, quantitative analysis of recirculation regions in 4D flow MRI with ITK-SNAP should be enhanced for use in clinical situations.

29 November 2023 in Animals
Verified
Journal Article
Open access
PDF file
CLChae-Yeong Lee
Chae-Yeong Lee
SLSung-Lim Lee
Sung-Lim Lee
EKEunJu Kim
EunJu Kim
JKJinsu Kang
Jinsu Kang
SJSunjun Jung
Sunjun Jung
DLDongbin Lee
Dongbin Lee
Whole blood viscosity, a hemorheological factor, is currently used for diagnosis, as it is correlated with various vascular diseases that are difficult to diagnose early with a general blood test. It was determined that it was necessary to set reference intervals for further studies and utilization of whole blood viscosity in cats, a representative companion animal, and this study was conducted. Fifty healthy cats were recruited for the study, and whole blood viscosity, complete blood count, and serum chemistry tests were performed. The reference intervals of whole blood viscosity were 15.169 to 43.684 cP at a shear rate of 1 s−1 reflecting diastole, and 3.524 to 5.544 cP at a shear rate of 300 s−1 reflecting systole. Red blood cells, hematocrit, hemoglobin, white blood cells, and neutrophils in the complete blood count, and total protein, albumin, globulin, and cholesterol in the serum chemistry were significantly correlated with whole blood viscosity. The results of this study set the reference intervals of whole blood viscosity for healthy cats in a wide shear rate range that has not yet been fully established, and its correlation with other blood indicators investigated.