Partial discharge (PD) detection plays an important role in online condition monitoring of electrical equipment and power cables. However, the noise of PD measurement will significantly reduce the performance of the detection algorithm. In this paper, we focus on the study of a PD noise reduction algorithm based on improved singular value decomposition (SVD) and multivariate variational mode decomposition (MVMD) for white Gaussian noise (WGN) and periodic narrowband interference signal noise. The specific noise reduction algorithm is divided into three noise reduction processes: The first noise reduction completes the suppression of narrowband interference in the noisy PD signal by the SVD algorithm with the guidance signal. The guidance signal is composed of a sinusoidal signal of the accurately estimated narrowband interference frequency component, and the amplitude is twice the maximum amplitude of the noisy PD signal. The second noise reduction decomposes the noisy PD signal after filtering the narrowband interference signal into k optimal intrinsic mode function by the MVMD after parameter optimization. By calculating the kurtosis value of each intrinsic mode function, it is determined whether it is the PD dominant component or the noise dominant component, and the noise dominant component is subjected to 3σ filtering to obtain the reconstructed PD signal. The third noise reduction uses a new wavelet threshold algorithm to denoise the reconstructed PD signal to obtain the denoised PD signal. The overall noise reduction algorithm proposed in this paper is compared with some existing methods. The results show that this method has a good effect on reducing the noise of PD signals measured in simulation and field.
Fault location technology is crucial for enhancing the efficiency of fault maintenance and ensuring the safety of the power supply in small current grounding systems. To address the challenge that traditional single-end positioning methods experience when identifying the reflected wave head and that the adaptability of wave head calibration methods is typically limited, a single-end location method of modulus wave velocity differences based on marine predator algorithm optimized multivariate variational mode decomposition (MVMD) and morphological gradient is proposed. Firstly, the minimum comprehensive entropy kurtosis ratio is used as the fitness function, and the marine predator algorithm is used to realize the automatic optimization of the mode number and penalty factor of the multivariate variational mode decomposition. Therefore, with the goal of decomposing the traveling wave characteristic signals with the most significant traveling wave characteristic information and the lowest noise component, the line-mode traveling wave and the zero-mode traveling wave are accurately decomposed. Secondly, the intrinsic mode function component with the smallest entropy kurtosis ratio is selected as the line-mode traveling wave characteristic signal and the zero-mode traveling wave characteristic signal, respectively, and the arrival time of the wave head is accurately calibrated by combining the morphological gradient value. Finally, the fault distance is calculated by the modulus wave velocity difference location formula and compared with the variational mode decomposition-Teager energy operator (VMD-TEO) method and the empirical mode decomposition _first-order difference method. The results show that the proposed method has the highest accuracy of positioning results, and the algorithm time is significantly reduced compared with the VMD-TEO method, and it has strong adaptability to different line types of faults, different fault initial conditions, and noise interference.
Due to the particularity of their process, petrochemical enterprises have high requirements for the reliability of power supply. If a large-scale blackout occurs due to a grounding fault, it will pose a huge threat to safe production. When the resonant grounding system of petrochemical enterprises faults, due to the complex fault process and weak fault signal, it is difficult to accurately detect the faulty feeder by traditional methods. This paper presents a new method of grey correlation degree based on adaptive frequency band. Firstly, the transient zero-sequence current of each feeder is decomposed by coif5 wavelet, and the low frequency band a5 (power frequency component) and high frequency band d1, d2 (noise signal) are removed. By stacking all of the remaining frequency band signals to construct the wavelet area matrix, the faulty feeder detection characteristic scale and the first faulty feeder detection result are obtained. Secondly, based on the faulty feeder detection characteristic scale, the second faulty feeder detection result is obtained by the average grey correlation degree matrix, which detects the faulty feeder according to the waveform correlation degree. Finally, the final faulty feeder detection result is obtained by equal weight voting. In MATLAB/Simulink, the 10 kV resonant grounding system of petrochemical enterprises is modeled. A large number of simulation results show that the faulty feeder detection method is not affected by the initial phase angle (0°, 45° and 90°), transition resistance (10 Ω, 100 Ω and 1000 Ω), fault distance (1 km, 8 km and 15 km) and overcompensation degree (5%, 8% and 10%), and has good sensitivity.
With the continuous attention to the safety of coal mine power systems, the traditional mine leakage protection method has its limitations; therefore, a leakage detection method based on 3 asymmetric capacitance (3AC) is proposed. This method is able to calculate the value of the insulation resistance in real time, enabling continuous monitoring of the insulation resistance and automatically disconnecting the fault line when there is an abnormal insulation resistance signal. In this paper, a mathematical model of the method is constructed, and its effectiveness and feasibility are verified by theoretical analysis and simulation.