22 April 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
Majid RoshanfarMajid Roshanfar
Majid Roshanfar
STSalar Taki
Salar Taki
ASAmir Sayadi
Amir Sayadi
RCRenzo Cecere
Renzo Cecere
JDJavad Dargahi
Javad Dargahi
AHAmir Hooshiar
Amir Hooshiar
Soft robots have gained popularity, especially in intraluminal applications, because their soft bodies make them safer for surgical interventions than flexures with rigid backbones. This study investigates a pressure-regulating stiffness tendon-driven soft robot and provides a continuum mechanics model for it towards using that in adaptive stiffness applications. To this end, first, a central single-chamber pneumatic and tri-tendon-driven soft robot was designed and fabricated. Afterward, the classic Cosserat’s rod model was adopted and augmented with the hyperelastic material model. The model was then formulated as a boundary-value problem and was solved using the shooting method. To identify the pressure-stiffening effect, a parameter-identification problem was formulated to identify the relationship between the flexural rigidity of the soft robot and internal pressure. The flexural rigidity of the robot at various pressures was optimized to match theoretical deformation and experiments. The theoretical findings of arbitrary pressures were then compared with the experiment for validation. The internal chamber pressure was in the range of 0 to 40 kPa and the tendon tensions were in the range of 0 to 3 N. The theoretical and experimental findings were in fair agreement for tip displacement with a maximum error of 6.40% of the flexure’s length.

9 January 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
TTTannaz Torkaman
Tannaz Torkaman
Majid RoshanfarMajid Roshanfar
Majid Roshanfar
JDJavad Dargahi
Javad Dargahi
AHAmir Hooshiar
Amir Hooshiar
Soft robots typically exhibit large deformation that makes integrating rigid sensors cumbersome. Especially for soft surgical robots, direct sensor-based feedback is required. In this study, we have proposed, modelled, prototyped, and validated a novel smart polymer-based soft sensor for integration with soft robots. Previously we have shown that the proposed smart polymer exhibits piezoresistivity. Thus, in this study, we integrated the proposed sensor with a flexural soft robot. Afterward, the sensor was calibrated through a series of experimental tests, and a multi-layer perceptron was trained for the calibration. The calibration showed a maximum root-mean-square error of 10.6 mN and a mean absolute error of 8±10 mN compared with the ground truth. The experimental validation showed that the proposed sensor and calibration method demonstrated a combined mean absolute error of 7.4±6.5 mN. In addition, the minimum detectable force of the sensor was less than 1 mN with a range of up to 284 mN. The system performance was compatible with representative intraluminal applications’ range and accuracy requirements.

23 December 2023 in Actuators
Verified
Journal Article
Open access
PDF file
Majid RoshanfarMajid Roshanfar
Majid Roshanfar
JDJavad Dargahi
Javad Dargahi
AHAmir Hooshiar
Amir Hooshiar
Soft robotics has emerged as a promising field due to the unique characteristics offered by compliant and flexible structures. Overcoming the challenge of precise position control is crucial in the development of such systems that require accurate modeling of soft robots. In response, a hybrid-actuated soft robot employing both air pressure and tendons was proposed, modeled, and validated using the dynamic Cosserat rod theory. This approach comprehensively addresses various aspects of deformation, including bending, torsion, shear, and extension. The designed robot was intended for robot-assisted cardiac ablation, a minimally invasive procedure that is used to treat cardiac arrhythmias. Within the framework of the Cosserat model, dynamic equations were discretized over time, and ordinary differential equations (ODEs) were solved at each time step. These equations of motion facilitated the prediction of the robot’s response to different control inputs, such as the air pressure and tension applied to the tendons. Experimental studies were conducted on a physical prototype to examine the accuracy of the model. The experiments covered a tension range of 0 to 3 N for each tendon and an air pressure range of 0 to 40 kPa for the central chamber. The results confirmed the accuracy of the model, demonstrating that the dynamic equations successfully predicted the robot’s motion in response to diverse control inputs.

22 March 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
Majid RoshanfarMajid Roshanfar
Majid Roshanfar
MSMohammadhossein Salimi
Mohammadhossein Salimi
AKAmir Hossein Kaboodrangi
Amir Hossein Kaboodrangi
SJSun-Joo Jang
Sun-Joo Jang
Albert SinusasAlbert Sinusas
Albert Sinusas
Bobak MosadeghBobak Mosadegh
Bobak Mosadegh
With an increasing number of elderly individuals, the demand for advanced technologies to treat cardiac diseases has become more critical than ever. Additionally, there is a pressing need to reduce the learning curve for cardiac interventionalists to keep pace with the rapid development of new types of procedures and devices and to expand the adoption of established procedures in more hospitals. This comprehensive review aims to shed light on recent advancements in novel robotic systems for cardiac interventions. To do so, this review provides a brief overview of the history of previously developed robotic systems and describes the necessity for advanced technologies for cardiac interventions to address the technological limitations of current systems. Moreover, this review explores the potential of cutting-edge technologies and methods in developing the next generation of intra-procedure autonomous navigation. Each highlighted topic undergoes a critical analysis to evaluate its technical limitations and the challenges that must be addressed for successful clinical implementation.

26 December 2023 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
MSMohammadhossein Salimi
Mohammadhossein Salimi
Majid RoshanfarMajid Roshanfar
Majid Roshanfar
NTNima Tabatabaei
Nima Tabatabaei
Bobak MosadeghBobak Mosadegh
Bobak Mosadegh
Personalized medicine transforms healthcare by adapting interventions to individuals’ unique genetic, molecular, and clinical profiles. To maximize diagnostic and/or therapeutic efficacy, personalized medicine requires advanced imaging devices and sensors for accurate assessment and monitoring of individual patient conditions or responses to therapeutics. In the field of biomedical optics, short-wave infrared (SWIR) techniques offer an array of capabilities that hold promise to significantly enhance diagnostics, imaging, and therapeutic interventions. SWIR techniques provide in vivo information, which was previously inaccessible, by making use of its capacity to penetrate biological tissues with reduced attenuation and enable researchers and clinicians to delve deeper into anatomical structures, physiological processes, and molecular interactions. Combining SWIR techniques with machine learning (ML), which is a powerful tool for analyzing information, holds the potential to provide unprecedented accuracy for disease detection, precision in treatment guidance, and correlations of complex biological features, opening the way for the data-driven personalized medicine field. Despite numerous biomedical demonstrations that utilize cutting-edge SWIR techniques, the clinical potential of this approach has remained significantly underexplored. This paper demonstrates how the synergy between SWIR imaging and ML is reshaping biomedical research and clinical applications. As the paper showcases the growing significance of SWIR imaging techniques that are empowered by ML, it calls for continued collaboration between researchers, engineers, and clinicians to boost the translation of this technology into clinics, ultimately bridging the gap between cutting-edge technology and its potential for personalized medicine.

21 January 2024 in Biomimetics
Verified
Journal Article
Open access
PDF file
Majid RoshanfarMajid Roshanfar
Majid Roshanfar
JDJavad Dargahi
Javad Dargahi
AHAmir Hooshiar
Amir Hooshiar
The current study investigated the geometry optimization of a hybrid-driven (based on the combination of air pressure and tendon tension) soft robot for use in robot-assisted intra-bronchial intervention. Soft robots, made from compliant materials, have gained popularity for use in surgical interventions due to their dexterity and safety. The current study aimed to design a catheter-like soft robot with an improved performance by minimizing radial expansion during inflation and increasing the force exerted on targeted tissues through geometry optimization. To do so, a finite element analysis (FEA) was employed to optimize the soft robot’s geometry, considering a multi-objective goal function that incorporated factors such as chamber pressures, tendon tensions, and the cross-sectional area. To accomplish this, a cylindrical soft robot with three air chambers, three tendons, and a central working channel was considered. Then, the dimensions of the soft robot, including the length of the air chambers, the diameter of the air chambers, and the offsets of the air chambers and tendon routes, were optimized to minimize the goal function in an in-plane bending scenario. To accurately simulate the behavior of the soft robot, Ecoflex 00-50 samples were tested based on ISO 7743, and a hyperplastic model was fitted on the compression test data. The FEA simulations were performed using the response surface optimization (RSO) module in ANSYS software, which iteratively explored the design space based on defined objectives and constraints. Using RSO, 45 points of experiments were generated based on the geometrical and loading constraints. During the simulations, tendon force was applied to the tip of the soft robot, while simultaneously, air pressure was applied inside the chamber. Following the optimization of the geometry, a prototype of the soft robot with the optimized values was fabricated and tested in a phantom model, mimicking simulated surgical conditions. The decreased actuation effort and radial expansion of the soft robot resulting from the optimization process have the potential to increase the performance of the manipulator. This advancement led to improved control over the soft robot while additionally minimizing unnecessary cross-sectional expansion. The study demonstrates the effectiveness of the optimization methodology for refining the soft robot’s design and highlights its potential for enhancing surgical interventions.