Latent cooling load accounts for 30% of the total load of air-conditioning, and its proportion is even higher in many tropical and subtropical climates. Traditional vapour-compression air-conditioning (VCAC) has a low coefficient of performance (COP) due to the refrigeration dehumidification process, which often makes necessary a great deal of subsequent re-heating. Technologies using conventional desiccants or sorbents for indoor moisture control are even less competitive than VCAC due to their high regeneration temperature, long cycling time and bulky components. Here, we report a novel high temperature cooling system that uses porous metal-organic frameworks (MOFs) as advanced sorbents for humidity control. We directly coat MOFs on the surface of evaporator and condenser. The system has no additional components compared to a traditional VCAC. The evaporator can simultaneously remove both the sensible and latent loads of the incoming air without reducing the temperature below its dew point. The regeneration of wet MOFs is completely driven by the residual heat from the condenser. The MOF-coated heat exchangers can achieve a cooling power density of 82 W·L −1 . We demonstrate that the system has a high COP, up to 7.9, and can save 36.1% of the energy required, compared to the traditional VCAC system with reheating. The amphiphilic MOFs used in the research have high water uptake, are made of low-cost raw materials and have high hydrothermal stability. They thus have the potential for being scaled up for large-scale applications in air conditioning.
Metal–organic frameworks (MOFs), an emerging class of porous sorbents, have become one of the most promising functional materials for indoor moisture regulation. However, the practical application of MOFs in building environments is challenging. Common shaping forms of MOFs (e.g., pellets, tablets, monoliths, granules, coating, etc.) may lead to agglomeration of MOF particles, higher usage costs, low efficiency, and material waste. Here, we report a new MOF-based electrospun nanofiber membrane with high porosity, light weight, and a large surface-area-to-volume ratio. MOF nanoparticles distributed on the fibers can fully contact moisture in the air, thus significantly enhancing MOFs’ utilization and performance. The results of the moisture adsorption test show that the improved MOF membrane has significantly higher water vapor uptake than most conventional hygroscopic materials and textiles in built environments. A building energy model was established to evaluate the MOF membrane’s effect on building energy consumption under different climates worldwide. The simulation results show that the MOF membrane can efficiently moderate indoor moisture fluctuation and has excellent energy-saving potential. The latent heat load reduction rate in summer can be up to 80–90% in arid/semi-arid climates and around 50% in temperate climates in a purely passive manner.
1 September 2019 in IOP Conference Series: Materials Science and Engineering
The use of desiccant-coated heat exchangers (DCHE) in air conditioning systems possesses great advantages in the independent control of both temperature and humidity, as well as low energy consumption and high coefficient of performance (COP). The paper presents a novel high temperature cooling system that uses metal-organic frameworks (MOFs) as sorbents for humidity control. MOFs are a new class of porous crystalline materials consisted of metal clusters and organic linkers, which have an excellent performance of water sorption due to the large specific surface areas and high porosity. In this research, we directly coat MOFs on the heat exchange surface of evaporator and condenser. The evaporator can simultaneously remove both the sensible and latent loads of the incoming air without reducing the temperature below its dew point. The regeneration of wet MOFs is completely driven by the residual heat from the condenser. We also make comparison between the MOF-coated cooling system and conventional desiccants coated ones (i.e. silica gel, zeolite) by way of tests and calculation. The results indicate that the dehumidification capacity of the MOF-coated heat exchanger outperforms other conventional desiccant coated ones under low regeneration temperature (∼50°C). The MOF-coated system has a high COP, up to 7.9, and can save 36.1% of the energy required, compared to the traditional vapour compression system with reheating. The amphiphilic MOFs used in the study have high water uptake and low regeneration temperature, and they thus have the potential for being scaled up for large-scale applications in energy efficient air conditioning systems.