Shuqing Cui

Shuqing Cui

Auto-generated profile, based on publicly available information

Shuqing Cui

Department of Civil Engineering, Technical University of Denmark, Lyngby, 2800, Denmark

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Building and Environment
Verified
Journal Article
Closed access
SCShuqing Cui
Shuqing Cui
MCMichaël Cohen
Michaël Cohen
PSPascal Stabat
Pascal Stabat
DMDominique Marchio
Dominique Marchio

16 October 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SCShuqing Cui
Shuqing Cui
Menghao QinMenghao Qin
Menghao Qin
AMAfsaneh Marandi
Afsaneh Marandi
VSVictoria Steggles
Victoria Steggles
SWSujing Wang
Sujing Wang
CSChristian Serre
Christian Serre
Latent cooling load accounts for 30% of the total load of air-conditioning, and its proportion is even higher in many tropical and subtropical climates. Traditional vapour-compression air-conditioning (VCAC) has a low coefficient of performance (COP) due to the refrigeration dehumidification process, which often makes necessary a great deal of subsequent re-heating. Technologies using conventional desiccants or sorbents for indoor moisture control are even less competitive than VCAC due to their high regeneration temperature, long cycling time and bulky components. Here, we report a novel high temperature cooling system that uses porous metal-organic frameworks (MOFs) as advanced sorbents for humidity control. We directly coat MOFs on the surface of evaporator and condenser. The system has no additional components compared to a traditional VCAC. The evaporator can simultaneously remove both the sensible and latent loads of the incoming air without reducing the temperature below its dew point. The regeneration of wet MOFs is completely driven by the residual heat from the condenser. The MOF-coated heat exchangers can achieve a cooling power density of 82 W·L −1 . We demonstrate that the system has a high COP, up to 7.9, and can save 36.1% of the energy required, compared to the traditional VCAC system with reheating. The amphiphilic MOFs used in the research have high water uptake, are made of low-cost raw materials and have high hydrothermal stability. They thus have the potential for being scaled up for large-scale applications in air conditioning.

1 November 2018 in Building and Environment
Verified
Journal Article
Closed access
XFXiaoxiao Feng
Xiaoxiao Feng
MQMenghao Qin
Menghao Qin
SCShuqing Cui
Shuqing Cui
CRCarsten Rode
Carsten Rode

1 November 2020 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
KZKan Zu
Kan Zu
MQMenghao Qin
Menghao Qin
SCShuqing Cui
Shuqing Cui

1 May 2013 in Energy and Buildings
Verified
Journal Article
Closed access
MCMarcello Caciolo
Marcello Caciolo
SCShuqing Cui
Shuqing Cui
PSPascal Stabat
Pascal Stabat
DMDominique Marchio
Dominique Marchio

1 October 2019 in Applied Thermal Engineering
Verified
Journal Article
Closed access
SCShuqing Cui
Shuqing Cui
AMAfsaneh Marandi
Afsaneh Marandi
GLGaëlle Lebourleux
Gaëlle Lebourleux
MTMireille Thimon
Mireille Thimon
MBMaxime Bourdon
Maxime Bourdon
CSChristian Serre
Christian Serre