Several works have been reported in powered hand orthosis in the last ten years for assistive or rehabilitative purposes. However, most of these approaches uses conventional actuators such as servo motors to power orthosis. In this work, we demonstrate the recently reported twisted and coiled polymeric (TCP) muscles to drive a compact, light, inexpensive and wearable upper extremity device, iGrab. A 3D printed orthotic hand module was designed, developed and tested for the performance. The device has six 2-ply muscles of diameter 1.35 mm with a length of 380 mm. We used a single 2-ply muscle for each finger and two 2-ply muscles for the thumb. Pulsed actuation of the muscles at 1.8 A current for 25 s with 7% duty cycle under natural cooling showed full flexion of the fingers within 2 s. Modeling and simulation were performed on the device using standard Euler–Lagrangian equations. Our artificial muscles powered hand orthosis demonstrated the capability of pinching and picking objects of different shapes, weights, and sizes.
8 October 2019 in Journal of Mechanisms and Robotics
A robotic finger actuated by novel artificial muscles known as twisted and coiled polymer (TCP) muscles has been proposed as an inexpensive, yet high-performance component of a robotic hand in recent years. In this paper, the Euler–Lagrangian method coupled with an electro-thermo-mechanical model-based transfer function was used for the analysis of finger joints in the hand. Experiments were performed at three power magnitudes provided to the TCP muscles, and the output angular displacements of the index finger subtended corresponding to the power levels were measured. The measured input and output parameters were used for system identification. To elucidate how the new artificial muscle influences the finger motion, two types of numerical simulations were performed: force input simulation (FIS) using measured force as an input and power input simulation (PIS) using measured electrical power as an input. Results were quantified statistically, and the simulated data were compared with the experimental results. Sensitivity analysis was also presented to understand the effect of the mechanical properties on the system. This model will help in understanding the effect of the TCP muscles and other similar smart actuators on the dynamics of the robotic finger.
This paper shows a detailed modeling of three-link robotic finger that is actuated by nylon artificial muscles and a simulink model that can be used for numerical study of a robotic finger. The robotic hand prototype was recently demonstrated in recent publication Wu, L., Jung de Andrade, M., Saharan, L.,Rome, R., Baughman, R., and Tadesse, Y., 2017, Compact and Low-cost Humanoid Hand Powered by Nylon Artificial Muscles, Bioinspiration & Biomimetics, 12 (2). The robotic hand is a 3D printed, lightweight and compact hand actuated by silver-coated nylon muscles, often called Twisted and coiled Polymer (TCP) muscles. TCP muscles are thermal actuators that contract when they are heated and they are getting attention for application in robotics. The purpose of this paper is to demonstrate the modeling equations that were derived based on Euler Lagrangian approach that is suitable for implementation in simulink model.