Arnaud Sanderink

Dr. Arnaud Sanderink


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2022 in Earth and Space Science
Verified
Journal Article
Open access
FKFabian Klenner
Fabian Klenner
MUMuhammad Umair
Muhammad Umair
WWWalter Walter
Walter Walter
NKNozair Khawaja
Nozair Khawaja
JHJon Hillier
Jon Hillier
FPFrank Postberg
Frank Postberg
Spaceborne impact ionization mass spectrometers, such as the Cosmic Dust Analyzer on board the past Cassini spacecraft or the SUrface Dust Analyzer being built for NASA's upcoming Europa Clipper mission, are of crucial importance for the exploration of icy moons in the Solar System, such as Saturn's moon Enceladus or Jupiter's moon Europa. For the interpretation of data produced by these instruments, analogue experiments on Earth are essential. To date, thousands of laboratory mass spectra have been recorded with an analogue experiment for impact ionization mass spectrometers. Simulation of mass spectra of ice grains in space is achieved by a Laser Induced Liquid Beam Ion Desorption (LILBID) approach. The desorbed cations or anions are analyzed in a time‐of‐flight mass spectrometer. The amount of unstructured raw data is increasingly challenging to sort, process, interpret and compare with data from space. Thus far this has been achieved manually for individual mass spectra because no database containing the recorded reference spectra was available. Here we describe the development of a comprehensive, extendable database containing cation and anion mass spectra from the laboratory LILBID facility. The database is based on a Relational Database Management System with a web server interface and enables filtering of the laboratory data using a wide range of parameters. The mass spectra can be compared not only with data from past and future space missions but also mass spectral data generated by other, terrestrial, techniques. The validated and approved subset of the database is available for general public (https://lilbid-db.planet.fu-berlin.de).

8 February 2023 in Analytical Chemistry
Verified
Journal Article
Closed access
ASArnaud Sanderink
Arnaud Sanderink
FKFabian Klenner
Fabian Klenner
IZIllia Zymak
Illia Zymak
JŽJan Žabka
Jan Žabka
FPFrank Postberg
Frank Postberg
CBChristelle Briois
Christelle Briois

1 June 2023 in Aerospace
Verified
Journal Article
Open access
PDF file
IZIllia Zymak
Illia Zymak
JŽJán Žabka
Ján Žabka
MPMiroslav Polášek
Miroslav Polášek
ASArnaud Sanderink
Arnaud Sanderink
JLJean-Pierre Lebreton
Jean-Pierre Lebreton
CBChristelle Briois
Christelle Briois
A new laboratory OrbitrapTM cell-based mass spectrometer, OLYMPIA (Orbitrap anaLYseur MultiPle IonisAtion), without a C-trap module, has been developed and constructed. The first operation of the OrbitrapTM cell-based device with the continuous ion source and without the C-trap module is reported. OLYMPIA is being developed and used as a workbench platform to test and develop technologies for the next generation of spaceborne mass spectrometers and as a laboratory instrument to perform high-resolution studies of space-relevant chemical processes. This instrument has been used to measure the quantitative composition of CO/N2/C2H4 mixtures of the same nominal mass using an electron ionization ion source. The relative abundance of ions has been measured using a short acquisition time (up to 250 ms) with a precision of better than 10% (for most abundant ions) and a mass resolution of 30,000–50,000 (full width at half maximum) over the mass range of m/z 28–86. The achieved mass accuracy of measurements is better than 20 ppm. This performance level is sufficient to resolve and identify the CO/N2/C2H4 components of the mixtures. The dynamic range and relative ion abundance measurements have been evaluated using a reference normal isotopic distribution of krypton gas. The measurement accuracy is about 10% for the 4 most abundant isotopes; 6 isotopes are detectable.

23 September 2022
Verified
Conference Paper
Open access
ASArnaud Sanderink
Arnaud Sanderink
FKFabian Klenner
Fabian Klenner
JZJan Zabka
Jan Zabka
FPFrank Postberg
Frank Postberg
JLJean-Pierre Lebreton
Jean-Pierre Lebreton
CBChristelle Briois
Christelle Briois
In 2005, a new type of mass spectrometer was commercialised for the first time, the Thermo Fisher Scientific OrbitrapTM. Using a Quadro-Logarithmic Electrostatic Ion Trap technology, Orbitrap mass spectrometers are able to reach ultra-high mass resolution1. For a decade, the Laboratoire de Physique et Chimie de l’Environnement et de l’Espace (LPC2E) is developing a spatialised version of the Orbitrap, the CosmOrbitrap2, to bring this high resolution in space exploration. The CosmOrbitrap is intended to be the mass analyser and acquisition system of laser ablation mass spectrometers aiming for planetary bodies like Europa or the Moon3,4.In this context, OLYMPIA - Orbitrap anaLYser MultiPle IonisAtion – has been develop to be used as a new laboratory test bench, and is adaptable to different ionisation methods. After a successful study of planetary atmosphere analogues using Electron Ionisation (EI)5, we now coupled OLYMPIA with the Laser Induced Liquid Beam Ion Desorption technique to analyse liquid water samples. For example, LILBID is able to accurately reproduce hypervelocity impact ionisation icy grains mass spectra6, such as those recorded by the Comic Dust Analyser7 (CDA) onboard Cassini in the vicinity of Saturn’s icy moon Enceladus. The LILBID setup is usually coupled with a Time-of-Flight (TOF) mass spectrometer, with a mass resolution of ~800 m/Δm. By coupling the LILBID technique to OLYMPIA and its Orbitrap analyser, we are now able to record hypervelocity icy grains analogue mass spectra with ultra-high mass resolution. The setup is currently able to measure H2O+ and H3O+ ions with a mass resolution of around 150.000 m/Δm (FWHM), with the spectral appearance matching mass spectra of icy grains impact ionisation in an impact velocity range of 15 to 20km/s. Future work aims to simulate lower impact velocities below 15 km/s as they are typically expected for flyby or orbiter missions.Those results will be implemented in the LILBID database8, and will be useful for the calibration and future data interpretation of the SUrface Dust Analyser (SUDA) mass spectrometer9, which will be onboard NASA’s Europa Clipper mission10 to characterize the habitability of Jupiter’s icy moon Europa. References1. Makarov, A. Electrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis. Anal. Chem. 72, 1156–1162 (2000).2. Briois, C. et al. Orbitrap mass analyser for in situ characterisation of planetary environments: Performance evaluation of a laboratory prototype. Planet. Space Sci. 131, 33–45 (2016).3. Arevalo, R. et al. An Orbitrap-based laser desorption/ablation mass spectrometer designed for spaceflight. Rapid Commun. Mass Spectrom. 32, 1875–1886 (2018).4. L. Willhite et al. CORALS: A Laser Desorption/Ablation Orbitrap Mass Spectrometer for In Situ Exploration of Europa, 2021 IEEE Aerospace Conference (50100), 2021, pp. 1-13, doi: 10.1109/AERO50100.2021.9438221.5. Zymak, I. et al. OLYMPIA - a compact laboratory Orbitrap-based high-resolution mass spectrometer laboratory set-up: Performance studies for gas composition measurement in analogues of planetary environments. https://meetingorganizer.copernicus.org/EGU21/EGU21-8424.html (2021) doi:10.5194/egusphere-egu21-8424.6. Klenner, F. et al. Analogue spectra for impact ionization mass spectra of water ice grains obtained at different impact speeds in space. Rapid Commun. Mass Spectrom. 33, 1751–1760 (2019).7. Srama, R. et al. The Cassini cosmic dust analyser. Space Sci. Rev. Volume 114, 465–518 (2004).8. Klenner, F. et al. Developing a Laser Induced Liquid Beam Ion Desorption Spectral Database as Reference for Spaceborne Mass Spectrometers. Earth and Space Science Under Review (2022).9. Kempf, S. et al. SUDA: A Dust Mass Spectrometer for Compositional Surface Mapping for a Mission to Europa. European Planetary Science Congress 2014, EPSC2014-229.10. Howell, S. M. & Pappalardo, R. T. NASA’s Europa Clipper—a mission to a potentially habitable ocean world. Nat. Commun. 11, 1311 (2020).

23 September 2022
Verified
Conference Paper
Open access
JZJan Zabka
Jan Zabka
MPMiroslav Polášek
Miroslav Polášek
YZYlja Zymak
Ylja Zymak
MLMichal Lacko
Michal Lacko
NSNikola Sixtová
Nikola Sixtová
MKMarwa Kashkoul
Marwa Kashkoul
Application of mass spectrometry in the space exploration has recently become a hot topic. It can be used for the analysis of space dust, micrometeorites and particles from larger objects.For the Czech SLAVIA (Space Laboratory for Advanced Variable Instruments and Applications) satellite project (expected to be launched in 2026 to the SSO 600km orbit) was designed the HANKA (Hmotnostný ANalyzér pre Kozmické Aplikace) space instrument - a high-resolution Orbitrap-based  electrostatic ion trap mass analyser. The instrument is based on a commercial mass analyser1 established in biology and medicine research, the so-called Orbitrap™  and the space CosmOrbitrap prototype (developed by LPC2E Orleans2). HANKA will bring this new technology into space to combine a CubeSat space version (4U) of this ion trap analyzer with an innovative in-situ hypervelocity impact ionization source for micrometeoroids.A laboratory version of this instrument (CIARA) is currently under construction, where ions can be generated by three different methods:Photons with molecules in the liquid phase (coupled with experiment LILBID(Laser Induced Liquid Bead Ion Desorption) Electrons with molecules in the gas phase (EI source) Photons with solid-phase molecules (MALDI or Laser Ablation)Based on the results obtained on the laboratory prototype, a CubeSat version of the high-resolution space mass spectrometer - HANKA - will be constructed.   References 1Makarov, A.; Anal. Chem. 2000, 72, 1156–1162. 2Briois C, Thissen R, Thirkell L, et al.; Planet Space Sci. 2016, 131, 33‐45. 3Zymak Y. et al.; article in preparation

3 July 2024
Verified
Conference Paper
Open access
MMMichaela Maleckova
Michaela Maleckova
JŽJán Žabka
Ján Žabka
YZYllia Zymak
Yllia Zymak
MPMiroslav Polášek
Miroslav Polášek
BCBarnabé Cherville
Barnabé Cherville
BABernd Abel
Bernd Abel
Mass spectrometry plays an important role in advancing space exploration. It provides unique insights into the composition of space dust, micrometeorites, and particles from distant large objects and can be used both in orbit and on the surface of an asteroid.The space instrument HANKA (Hmotnostní ANalyzér pro Kosmické Aplikace) is a high-resolution mass spectrometer based on an electrostatic ion trap, which is a principal component of commercial instruments[1] established in biology and medicine research, the so-called Orbitrap™, and the space CosmOrbitrap prototype (developed in LPC2E Orleans[2]). HANKA can take this new technology into space, combining a compact CubeSat space version of this high-resolution ion trap mass analyzer with a velocity/charge detector and hypervelocity impact ionization source.Figure 1: HANKA – CubeSat space version (a), laboratory prototype (b), and preliminary data from EI source(c)[3]Based on the results obtained from the laboratory prototype, a miniature CubeSat version of the high-resolution mass spectrometer for in-situ exploration in space will be constructed. The proposed parameters of the CubeSat module HANKA are:> Resolution: up to 50 000 at m/z 200 > Mass Range: 2 – 3000 m/z > Dimension: 200x200x100 mm (4U) > Weight: < 6kg> Power: 5-10 WAcknowledgements: This work was supported by the Czech Science Foundation (grant No. 21-11931J)References[1] Makarov, A.; Anal. Chem. 2000, 72, 1156–1162.[2] Briois C., Thissen R., Thirkell L., et al.; Planet Space Sci. 2016, 131, 33‐45.[3] Zymak Y., Zabka J., Polášek M., et al.; al.; Aerospace 2023, 10(6), 522.