Illia Zymak

Dr. Illia Zymak


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2023 in Aerospace
Verified
Journal Article
Open access
PDF file
IZIllia Zymak
Illia Zymak
JŽJán Žabka
Ján Žabka
MPMiroslav Polášek
Miroslav Polášek
ASArnaud Sanderink
Arnaud Sanderink
JLJean-Pierre Lebreton
Jean-Pierre Lebreton
CBChristelle Briois
Christelle Briois
A new laboratory OrbitrapTM cell-based mass spectrometer, OLYMPIA (Orbitrap anaLYseur MultiPle IonisAtion), without a C-trap module, has been developed and constructed. The first operation of the OrbitrapTM cell-based device with the continuous ion source and without the C-trap module is reported. OLYMPIA is being developed and used as a workbench platform to test and develop technologies for the next generation of spaceborne mass spectrometers and as a laboratory instrument to perform high-resolution studies of space-relevant chemical processes. This instrument has been used to measure the quantitative composition of CO/N2/C2H4 mixtures of the same nominal mass using an electron ionization ion source. The relative abundance of ions has been measured using a short acquisition time (up to 250 ms) with a precision of better than 10% (for most abundant ions) and a mass resolution of 30,000–50,000 (full width at half maximum) over the mass range of m/z 28–86. The achieved mass accuracy of measurements is better than 20 ppm. This performance level is sufficient to resolve and identify the CO/N2/C2H4 components of the mixtures. The dynamic range and relative ion abundance measurements have been evaluated using a reference normal isotopic distribution of krypton gas. The measurement accuracy is about 10% for the 4 most abundant isotopes; 6 isotopes are detectable.

23 December 2024 in Photonics
Verified
Journal Article
Open access
PDF file
IZIllia Zymak
Illia Zymak
MFMarco Favetta
Marco Favetta
GGGabriele Maria Grittani
Gabriele Maria Grittani
CLCarlo Maria Lazzarini
Carlo Maria Lazzarini
GTGiovanni Francesco Tassielli
Giovanni Francesco Tassielli
SBSergei Bulanov
Sergei Bulanov
We demonstrate a method to characterize the beam energy, transverse profile, charge, and dose of a pulsed electron beam generated by a 1 kHz TW laser-plasma accelerator. The method is based on imaging with a scintillating screen in an inhomogeneous, orthogonal magnetic field produced by a wide-gap magnetic dipole. Numerical simulations were developed to reconstruct the electron beam parameters accurately. The method has been experimentally verified and calibrated using a medical LINAC. The energy measurement accuracy in the 6–20 MeV range is proven to be better than 10%. The radiation dose has been calibrated by a water-equivalent phantom, RW3, showing a linear response of the method within 2% in the 0.05–0.5 mGy/pulse range.