Yuchi Tanaka

Mr. Yuchi Tanaka

Graduate School of Medical Sciences, Kitasato University, Sagamihara, Kanagawa, Japan
orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2001 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
MJM. Jablonski
M. Jablonski
YTYuchi Tanaka
Yuchi Tanaka
HYH. Yaguchi
H. Yaguchi
KFK. Furuki
K. Furuki
KSKiminori Sato
Kiminori Sato
KKK. Kikuchi
K. Kikuchi
Conventional dispersion-slope compensation filters suffer from a fundamental tradeoff between the amount of dispersion-slope compensation and the compensation bandwidth. A novel multireflection device, composed of two coupled cavity filters in a parallel configuration is proposed that has an adjustable dispersion-slope independent of the compensation bandwidth. The device provides an adjustable dispersion-slope value between -6.7 and -35.7 ps/sup 3/ over a bandwidth of 3 nm. The center wavelength is adjustable over a 10-nm range.

19 May 2022 in Journal of Chemical Education
Verified
Journal Article
Closed access
HHHaruka Honda
Haruka Honda
NMNoritaka Miyamoto
Noritaka Miyamoto
HMHisayuki Miyajima
Hisayuki Miyajima
YTYuchi Tanaka
Yuchi Tanaka

16 May 2023 in Current Oncology
Verified
Journal Article
Open access
PDF file
KFKyohei Fujii
Kyohei Fujii
MNMasahiro Nakano
Masahiro Nakano
SKShogo Kawakami
Shogo Kawakami
YTYuchi Tanaka
Yuchi Tanaka
TKTakuro Kainuma
Takuro Kainuma
HIHiromichi Ishiyama
Hiromichi Ishiyama
The indications for stereotactic body radiotherapy (SBRT) for prostate cancer have increased. However, the relationships between adverse events and risk factors remain unclear. This study aimed to clarify associations between adverse events and dose index for prostate SBRT. Participants comprised 145 patients irradiated with 32–36 Gy in 4 fractions. Radiotherapy-related risk factors such as dose-volume histogram parameters and patient-related risk factors such as T stage and Gleason score were evaluated in a competing risk analysis. Median follow-up duration was 42.9 months. A total of 9.7% had acute Grade ≥ 2 GU toxicities and 4.8% had acute Grade ≥ 2 GI toxicities. A total of 11.1% had late Grade ≥ 2 GU toxicities and 7.6% had late Grade ≥ 2 GI toxicities. Two (1.4%) patients suffered from late Grade 3 GU toxicities. Similarly, two (1.4%) patients suffered from late Grade 3 GI toxicities. Acute GU and GI events correlated with prostate volume and dose to the hottest 10 cc volume (D10cc)/volumes receiving a minimum of 30 Gy (V30 Gy) of rectum, respectively. Late GI toxicity, frequency, and rectal hemorrhage correlated with rectal D0.1 cc/D1 cc, maximum dose to the bladder, and rectal D0.1 cc, respectively. Toxicities after prostate SBRT using 32–36 Gy/4 fractions were acceptable. Our analysis showed that acute toxicities correlated with volume receiving a medium dose level, and late toxicities correlated with highest point dose of organs at risk.

2 November 2023 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
YTYuchi Tanaka
Yuchi Tanaka
MHMasatoshi Hashimoto
Masatoshi Hashimoto
MIMinoru Ishigami
Minoru Ishigami
MNMasahiro Nakano
Masahiro Nakano
THTomoyuki Hasegawa
Tomoyuki Hasegawa
Background: Intensity-modulated radiation therapy (IMRT) requires delivery quality assurance (DQA) to ensure treatment accuracy and safety. Irradiation techniques such as helical tomotherapy (HT) have become increasingly complex, rendering conventional verification methods insufficient. This study aims to develop a novel DQA system to simultaneously verify dose distribution and multi-leaf collimator (MLC) opening during HT. Methods: We developed a prototype detector consisting of a cylindrical plastic scintillator (PS) and a cooled charge-coupled device (CCD) camera. Scintillation light was recorded using a CCD camera. A TomoHDA (Accuray Inc.) was used as the irradiation device. The characteristics of the developed system were evaluated based on the light intensity. The IMRT plan was irradiated onto the PS to record a moving image of the scintillation light. MLC opening and light distribution were obtained from the recorded images. To detect MLC opening, we placed a region of interest (ROI) on the image, corresponding to the leaf position, and analyzed the temporal change in the light intensity within each ROI. Corrections were made for light changes due to differences in the PS shape and irradiation position. The corrected light intensity was converted into the leaf opening time (LOT), and an MLC sinogram was constructed. The reconstructed MLC sinogram was compared with that calculated using the treatment planning system (TPS). Light distribution was obtained by integrating all frames obtained during IMRT irradiation. The light distribution was compared with the dose distribution calculated using the TPS. Results: The LOT and the light intensity followed a linear relationship. Owing to MLC movements, the sensitivity and specificity of the reconstructed sinogram exceeded 97%, with an LOT error of − 3.9 ± 7.8%. The light distribution pattern closely resembled that of the dose distribution. The average dose difference and the pass rate of gamma analysis with 3%/3 mm were 1.4 ± 0.2% and 99%, respectively. Conclusion: We developed a DQA system for simultaneous and accurate verification of both dose distribution and MLC opening during HT.

1 January 1997 in The Review of Laser Engineering
Verified
Journal Article
Open access
PDF file
TOToshiaki Okuno
Toshiaki Okuno
MOMasashi Ohnishi
Masashi Ohnishi
MNMasayuki Nishimura
Masayuki Nishimura
ATA. Takada
A. Takada
WIW. Imajuku
W. Imajuku
YTYuchi Tanaka
Yuchi Tanaka
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies