A muon collider would enable the big jump ahead in energy reach that is needed for a fruitful exploration of fundamental interactions. The challenges of producing muon collisions at high luminosity and 10 TeV centre of mass energy are being investigated by the recently-formed International Muon Collider Collaboration. This Review summarises the status and the recent advances on muon colliders design, physics and detector studies. The aim is to provide a global perspective of the field and to outline directions for future work.
1 February 2002 in Review of Scientific Instruments
For the needs of future heavy ion accelerators, electron cyclotron resonance ion sources (ECRISs) should be able to deliver higher intensities and higher charge states. The mA level intensity has already been reached by room temperature ECRIS for medium charge states of light elements However, such level of intensity for heavy elements (like for CERN/LHC and GSI) requires more powerful ECRIS with higher electron densities (up to On the other hand, an optimized magnetic configuration system has to be used in order to obtain the suitable compromise between the electron confinement and the high flux ion losses. Before the design of the future “high intensity ECRIS,” experiments have been performed with the superconducting SERSE source both at 18 and 28 GHz. After an overview of major results recently obtained, some scaling laws will be presented. Our results show that much larger intensities and charges can be reached with ECRIS. Then, we will show how the next ECRIS generation will look like, based on the scaling laws derived in the above-mentioned experiments.
1 February 2010 in Review of Scientific Instruments
The suitable source for the production of intense beams for high power accelerators must obey to the request of high brightness, stability, and reliability. The 2.45 GHz off-resonance microwave discharge sources are the ideal device to generate the requested beams, as they produce multimilliampere beams of protons, deuterons, and monocharged ions, remaining stable for several weeks without maintenance. A description of different technical designs will be given, analyzing their strength, and weakness, with regard to the extraction system and low energy beam transport line, as the presence of beam halo is detrimental for the accelerator.
1 November 2001 in Review of Scientific Instruments
The SERSE source [P. Ludwig et al., Rev. Sci. Instrum. 69, 4082 (1998), and references therein] is a superconducting electron cyclotron resonance (ECR) ion source, operating at the Laboratori Nazionali del Sud in Catania since 1998; it is currently used as the main injector for the K-800 superconducting cyclotron. Its high magnetic field provides a high plasma confinement and large currents of highly charged ions, as compared to conventional sources. It can efficiently operate at the microwave frequency of 14 and 18 GHz [S. Gammino and G. Ciavola, Rev. Sci. Instrum. 71, 631 (2000); S. Gammino et al., ibid.70, 3577 (1999)] and has been used as a test bench for injection at 28 GHz. High-frequency operation is expected to create a higher plasma density, thus resulting in larger currents of multiply charged ions. In this article, we report the first operation of an ECR ion source at 28 GHz by using a gyrotron. The gyrotron itself and the waveguide line are described, along with the operational results (in xenon gas for the sake of simplicity). Given the limited amount of power (about 4 kW), which can be injected in the plasma chamber during dc-mode operation, the results are less outstanding than in the pulsed mode (up to 6.5 kW). However, in both cases the beam intensities are far better than the ones obtained by the other ECR ion sources operating at lower frequencies.
1 February 2008 in Review of Scientific Instruments
A set of measurements with the CAPRICE ion source at the GSI test bench has been carried out to investigate its behavior in terms of intensity and shape of the extracted beam when the microwaves generating the plasma sweep in a narrow range of frequency (±40MHz) around the klystron center frequency (14.5GHz). Remarkable variations have been observed depending on the source and the beamline operating parameters, confirming that a frequency dependent electromagnetic distribution is preserved even in the presence of plasma inside the source. Moreover, these observations confirm that the frequency tuning is a powerful method to optimize the electron cyclotron resonance ion source performances. A description of the experimental setup and of the obtained results is given in the following.
22 January 2015 in The European Physical Journal D