Jelena Selivonec

Dr. Jelena Selivonec

Applied Mechanics Department, Vilnius Gediminas Technical University, Vilnius, Vilniaus Miestas, Lithuania
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
OCOlga Chabarova
Olga Chabarova
JSJelena Selivonec
Jelena Selivonec
AHAlicia Menendez Hurtado
Alicia Menendez Hurtado
An evaluation of the impact of osteoporosis on loss of spinal stability, with or without intervertebral disc degeneration, using computational analysis is presented. The research also investigates the correlation between osteoporosis and intervertebral disc degeneration. Three-dimensional finite element models of human lumbar spine segments were used to assess the influence of osteoporosis on spinal stability. Five different models of age-related degeneration were created using various material properties for trabecular bone and intervertebral discs. Calculation results indicate that in a spine with osteoporosis, the deformation of the intervertebral discs can increase by more than 30% when compared to a healthy spine. Thus, intervertebral disc deformation depends not only on the degree of degeneration of the discs themselves, but their deformation is also influenced by the degree of osteoporosis of the vertebrae. Additionally, the load-bearing capacity of the spine can decrease by up to 30% with osteoporosis, regardless of the degree of intervertebral disc deformation. In conclusion, osteoporosis can contribute to intervertebral disc degeneration.

19 February 2017 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
AKAlgimantas Krenevičius
Algimantas Krenevičius
RKRimantas Kačianauskas
Rimantas Kačianauskas
JSJelena Selivonec
Jelena Selivonec
SSStanislav Stupak
Stanislav Stupak

31 March 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VAVidmantas Alekna
Vidmantas Alekna
OAOleg Ardatov
Oleg Ardatov
JSJelena Selivonec
Jelena Selivonec
OCOlga Chabarova
Olga Chabarova
The knee joint is a complex biomechanical subsystem, modeling of which can reveal a deeper understanding of the processes occurring within it. The purpose of this study is to examine the stress alteration in bone based on mechanical properties of cartilage. To achieve this, a numerical model of the knee joint was developed and tested under different displacement values. The mechanical behavior of the model was represented by considering the hyperelastic properties of soft tissues, along with the verification of trabecular structure of bones, resulting in a more realistic mechanical depiction of the biological subsystem. The results showed that as the stiffness of the cartilage increased; the distribution of stresses in the bone became uneven; and stress concentrators dispersed over articular surface, while in the case of mild cartilage no stress concentrators were expressed. The proposed modeling approach allows the adaptation of patient-specific data in order to predict the outcomes of tissue diseases. The obtained results allow us to state that taking into account the non-linear properties of soft tissues is extremely important for assessing the stress state of the entire biological subsystem. The main difficulty, however, is the lack of data regarding the mechanical behavior of tissues in certain diseases.

12 May 2011 in Structural and Multidisciplinary Optimization
Verified
Journal Article
Closed access
PDF file
KVKȩstutis Vislavičius
Kȩstutis Vislavičius
RKRimantas Kačianauskas
Rimantas Kačianauskas
AKAlgimantas Krenevičius
Algimantas Krenevičius
JSJelena Selivonec
Jelena Selivonec

1 January 2024 in Acta of Bioengineering and Biomechanics
Verified
Journal Article
Closed access
OCOlga Chabarova
Olga Chabarova
JSJelena Selivonec
Jelena Selivonec
Purpose This study aimed to evaluate the biomechanical response or load transfer on the osteoporotic L1 vertebra under torsional loading. Methods To achieve this goal, a numerical model of osteoporotic vertebra in various trabecular bone degenerations was developed and tested. The mechanical behavior of the model was represented taking into account the anisotropic properties of the cancellous bone, which provided a more realistic mechanical picture of the biological subsystem. To ensure the reliability of osteoporotic degradation, the thinning of cortical bone and the appearance of gaps between trabecular bone and cortical bone were also taken into account when creating the models. Results Finite element analysis showed that the deformations of cortical bone thinning and detachment of the cortical bone from the trabecular tissue lead to local instability of the vertebrae. As a result, the cortical bone of a vertebra loses its load-bearing capacity, even if the strength limit is not reached. Conclusions The results obtained allow us to state that taking into account the thinning of the trabeculae, which creates voids, is extremely important for load-bearing capacity of osteoporotic vertebrae. However, a limitation of this study is the lack of experimental data to ensure consistency with the computer simulation results.

19 October 2025 in Mathematics
Verified
Journal Article
Open access
PDF file
AHAlicia Menendez Hurtado
Alicia Menendez Hurtado
SBSergejus Borodinas
Sergejus Borodinas
OCOlga Chabarova
Olga Chabarova
JSJelena Selivonec
Jelena Selivonec
Eugenius StupakEugenius Stupak
Eugenius Stupak
Understanding the nonlinear mechanical behaviour of mitral valve chordae tendineae is critical for accurate biomechanical modelling in cardiac simulations. This study integrates high-resolution 3D finite element analysis with experimentally derived Cauchy stress–Green–Lagrange strain data to capture both material and geometric nonlinearities. A one-dimensional formulation incorporating strain-dependent elasticity and large deformation kinematics was developed and validated against 3D simulations in COMSOL Multiphysics. Calibrated using experimental stress–strain data and validated against high-fidelity 3D finite element simulations in COMSOL, it reveals that neglecting transverse deformation overestimates axial force by 7%. Cross-sectional area reduction during stretch remained consistently around 12%, underscoring the importance of Poisson effects. A polynomial fit to the strain-dependent modulus of elasticity enables efficient force prediction with excellent agreement to experimental data. These results advance the mathematical modelling of biological tissues with nonlinear hyperelastic behaviour, providing a foundation for patient-specific simulations and real-time predictive tools in cardiovascular engineering.