Eugenius Stupak

Dr. Eugenius Stupak

orcid
Associate professor

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2017 in Mathematical Modelling and Analysis
Verified
Journal Article
Open access
PDF file
VSVadimas Starikovičius
Vadimas Starikovičius
AKArnas Kačeniauskas
Arnas Kačeniauskas
AMAlgirdas Maknickas
Algirdas Maknickas
Eugenius StupakEugenius Stupak
Eugenius Stupak
RPRuslan Pacevič
Ruslan Pacevič
GDGiedrius Davidavičius
Giedrius Davidavičius
Mathematical modelling of cardiac haemodynamics presents a great challenge to the computational scientists due to numerous numerical issues and required computational resources. In this paper, we study the parallel performance of 3D simulation software for the blood flow through the aortic valve. The fluid flow problem with the open aortic valve leaflets is formulated and solved in parallel. The choice between the segregated and coupled numerical schemes is discussed and investigated. We present and compare the parallel performance results of both types of parallel solvers. We investigate their strong and weak scalability.

8 May 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AKArnas Kačeniauskas
Arnas Kačeniauskas
RPRuslan Pacevič
Ruslan Pacevič
Eugenius StupakEugenius Stupak
Eugenius Stupak
JRJerzy Rojek
Jerzy Rojek
MCMarcin Chmielewski
Marcin Chmielewski
SNSzymon Nosewicz
Szymon Nosewicz
Sintered porous materials present challenges for any modeling approach applied to simulate their damage evolution because of their complex microstructure, which is crucial for the initialization and propagation of microcracks. This paper presents discrete element simulations of the damage evolution of a NiAl-based material reconstructed by micro-CT imaging. A novel geometry reconstruction procedure based on micro-CT images and the adapted advancing front algorithm fills the solid phase using well-connected irregular and highly dense sphere packing, which directly represents the microstructure of the porous material. Uniaxial compression experiments were performed to identify the behavior of the NiAl sample and validate the discrete element model. Discrete element simulations based on micro-CT imaging revealed a realistic representation of the damage evolution and stress–strain dependency. The stress and strain of the numerically obtained curve peak differed from the experimentally measured values by 0.1% and 4.2%, respectively. The analysis of damage evolution was performed according to the time variation rate of the broken bond count. Investigation of the stress–strain dependencies obtained by using different values of the compression strain rate showed that the performed simulations approached the quasi-static state and achieved the acceptable accuracy within the limits of the available computational resources. The proposed stress scaling technique allowed a seven times increase of the size of the time step, which reduced the computing time by seven times.

19 October 2025 in Mathematics
Verified
Journal Article
Open access
PDF file
AHAlicia Menendez Hurtado
Alicia Menendez Hurtado
SBSergejus Borodinas
Sergejus Borodinas
OCOlga Chabarova
Olga Chabarova
JSJelena Selivonec
Jelena Selivonec
Eugenius StupakEugenius Stupak
Eugenius Stupak
Understanding the nonlinear mechanical behaviour of mitral valve chordae tendineae is critical for accurate biomechanical modelling in cardiac simulations. This study integrates high-resolution 3D finite element analysis with experimentally derived Cauchy stress–Green–Lagrange strain data to capture both material and geometric nonlinearities. A one-dimensional formulation incorporating strain-dependent elasticity and large deformation kinematics was developed and validated against 3D simulations in COMSOL Multiphysics. Calibrated using experimental stress–strain data and validated against high-fidelity 3D finite element simulations in COMSOL, it reveals that neglecting transverse deformation overestimates axial force by 7%. Cross-sectional area reduction during stretch remained consistently around 12%, underscoring the importance of Poisson effects. A polynomial fit to the strain-dependent modulus of elasticity enables efficient force prediction with excellent agreement to experimental data. These results advance the mathematical modelling of biological tissues with nonlinear hyperelastic behaviour, providing a foundation for patient-specific simulations and real-time predictive tools in cardiovascular engineering.