Jungsung Kim

Jungsung Kim


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
YKYeokyung Kang
Yeokyung Kang
JKJungsung Kim
Jungsung Kim
JSJae Ang Sim
Jae Ang Sim
MMMyeong Moon
Myeong Moon
JPJong-Chul Park
Jong-Chul Park
BLByung Hoon Lee
Byung Hoon Lee
Proximal fibular osteotomy (PFO) was found to relieve pain and improve knee function in patients with medial compartment knee osteoarthritis (OA). Therapy redistributes the load applied from the inside to the outside and alleviates the load applied on the inside through fibula osteotomy. Therefore, the clinical effect of fibular osteotomy using the finite element (FE) method was evaluated to calculate the exact change in stress inside a knee joint with varus deformity. Using CT and MRI images of a patient’s lower extremities, 3D models of the bone, cartilage, meniscus, and ligaments were constructed. The varus angle, representing the inward angulation of the knee, was increased by applying a force ratio in the medial and lateral directions. The results showed that performing proximal fibular osteotomy led to a significant reduction in stress in the medial direction of the meniscus and cartilage. The stress reduction in the lateral direction was relatively minor. In conclusion, the study demonstrated that proximal fibular osteotomy effectively relieves stress and redistributes the load in the knee joints of patients with medial compartment knee osteoarthritis. The findings emphasize the importance of considering force distribution and the position of fibular osteotomy to achieve optimal clinical outcomes.

26 October 2022 in Bio-Design and Manufacturing
Verified
Journal Article
Open access
PDF file
YKYeokyung Kang
Yeokyung Kang
DLDasol Lim
Dasol Lim
DSDoo-Hoon Sun
Doo-Hoon Sun
JPJong-Chul Park
Jong-Chul Park
JKJungsung Kim
Jungsung Kim
The use of commercial products such as a cup and liner for total hip arthroplasty for patients with severe bone defects has a high probability of failure. In these patients the cup alone cannot cover the bone defect, and thus, an additional augment or cage is required. In this study, we designed three-dimensional (3D) printable bone augments as an alternative to surgeries using reinforcement cages. Thirty-five sharp-edged bone augments of various sizes were 3D printed. A biporous structure was designed to reduce the weight of the augment and to facilitate bone ingrowth. Two types of frames were used to prevent damage to the augment’s porous structure and maintain its stability during printing. Furthermore, two types of holes were provided for easy augment fixation at various angles. Fatigue tests were performed on a combination of worst-case sizes derived using finite element analysis. The test results confirmed the structural stability of the specimens at a load of 5340 N. Although the porosity of the specimens was measured to be 63.70%, it cannot be said that the porous nature was uniformly distributed because porosity tests were performed locally and randomly. In summary, 3D-printable biporous bone augments capable of bonding from various angles and bidirectionally through angulation and bottom-plane screw holes are proposed. The mechanical results with bone augments indicate good structural safety in patients. However, further research is necessary to study the clinical applications of the proposed bone augment. Graphic abstract

24 June 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
BLByung Hoon Lee
Byung Hoon Lee
YKYeokyung Kang
Yeokyung Kang
SCSung Ha Cho
Sung Ha Cho
MMMyung Moon
Myung Moon
JSJae Ang Sim
Jae Ang Sim
JKJungsung Kim
Jungsung Kim
Minimally invasive plate osteosynthesis is the most commonly used minimally invasive surgery technique for tibial fractures, possibly involving single or dual plate methods. Herein, we performed a finite element analysis to investigate plate strength according to the plate type, length, and presence of a fibula by constructing a three-dimensional tibia model. A thickness of 20 mm was cut 50 mm distal from the lateral plateau, and the ligaments were created. Plates were modeled with lengths of 150, 200, and 250 mm and mounted to the tibia. Screws were arranged to avoid overlapping in the dual plating. The von-Mises stress applied to the plates was measured by applying a load of 1 body weight. Dual plates showed the least stress with low displacement, followed by medial and lateral plates. As the plate length increased, the average stress gradually decreased, increasing plate safety. The difference in the influence of the fibula depending on the presence of proximal fibula osteotomy showed that the average stress increased by 35% following proximal fibula osteotomy in the D1(Plate type: Dual plate, Medial plate length: 150 mm, Lateral plate length: 200 mm, Non Proximal fibula osteotomy) and D1P(Plate type: Dual plate, Medial plate length: 150 mm, Lateral plate length: 200 mm, Proximal fibula osteotomy) models, confirming the necessity of the fibula model. There is no consensus guideline for treatment of this kind of fracture case. A single fracture plate can decrease the risk of skin damage, ligament damage, and wound infection, but because of its design, it cannot provide sufficient stability and satisfactory reduction of the condylar fragment, especially in cases of comminution or coronal fracture. So, these results will help clinicians make an informed choice on which plate to use in patients with tibial fractures.

27 August 2022 in Journal of Orthopaedics
Verified
Journal Article
Open access
YKYeokyung Kang
Yeokyung Kang
DSDoo-Hoon Sun
Doo-Hoon Sun
JPJong-Chul Park
Jong-Chul Park
JKJungsung Kim
Jungsung Kim
Background: Owing to an increase in the number of hip arthroplasty surgeries, the number of implant replacement surgeries is increasing rapidly as well. This necessitates the study of hip joint conditions. Therefore, Paprosky defined a classification system to indicate the degree of damage to the hip joint. In this study, a customised hip implant suitable for Paprosky classification Type ⅡC and over was designed. The shape, suitability, and mechanical safety of the worst-case model for the implant were evaluated. Materials and methods To identify the implant size depending on states over Type ⅡC acetabulum bone loss, a size range was selected and a customised implant was designed according to the computed tomography data within the size range. The implant was designed for the flange, hook, and flattened model types. The worst-case selection test was conducted using finite element analysis. The von Mises stresses of the flange, hook, and flattened models were found as 76.223, 136.99, and 80.791 MPa, respectively. Therefore, the hook-type model was selected as the worst case for the mechanical performance test. Results: A bending test was conducted on the hook-type model without fracture and failure at 5344.56 N. The proposed customised implant was found suitable for Type ⅢA acetabulum bone loss, whereas the shape suitability and mechanical safety were verified for the worst case. Conclusion: The shape of a customised implant suitable for Paprosky ⅢA type was designed. The shape suitability and mechanical safety were evaluated using finite element method analysis and bending tests. Clinical validation is required through subsequent clinical evaluation.

19 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YLYongkyung Lee
Yongkyung Lee
HYHai Mi Yang
Hai Mi Yang
JJJinju Jang
Jinju Jang
DKDai-Soon Kwak
Dai-Soon Kwak
JKJungsung Kim
Jungsung Kim
Dohyung LimDohyung Lim
Dohyung Lim
Four pairs of fresh-frozen cadaver knees (eight knees, four male knees) with a mean age of 72 ± 7 years were used for tests involving a customized simulator capable of controlling quadriceps loading conditions. The muscle force distribution of the quadriceps for the normal loading condition was applied on the basis of muscle cross-sectional area data, as previously reported (VM: 31 N; RF/VI: 49 N; VL: 45 N). To simulate vastus medialis (VM) impairment, we set the muscle force for VM in the muscle force distribution of the quadriceps at zero (VM: 0 N; RF/VI: 49 N; VL: 45 N). The joint reaction forces and moments on knee joints that underwent total knee arthroplasty (TKA) did not differ significantly according to VM impairment status for all flexion angles (p > 0.05). Nevertheless, the vectors of internal–external moments mostly showed a tendency for alteration from external to internal due to VM impairment. This tendency was evident in 9 cases in 12 total test pairs (with and without VM impairment). Furthermore, the vectors of the anterior–posterior reaction forces mostly showed a tendency to increase anteriorly due to VM impairment. This tendency was also evident in 9 cases in 12 total test pairs (with and without VM impairment). These results indicate that posterior dislocation of the tibia may be induced if VM impairment occurs after TKA. In conclusion, VM impairment in knee joints undergoing TKA may contribute to posterior dislocation of the tibia by a paradoxical roll-back with enhancements of the anterior joint reaction force and external moment during knee-joint flexion. Our findings may be valuable for understanding the mechanism of potential instability and malfunction due to VM impairment in knee joints after TKA, and may help to optimize clinical/rehabilitation training plans to improve the prognosis (stability and function) of knee joints undergoing TKA.

4 February 2026 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
DLDonghwan Lee
Donghwan Lee
JOJoo Han Oh
Joo Han Oh
JLJinkyu Lee
Jinkyu Lee
SJSungwook Jung
Sungwook Jung
JKJungsung Kim
Jungsung Kim
CSChoongsoo Shin
Choongsoo Shin