Jie Zhang

Dr. Jie Zhang

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2010 in NDT & E International
Verified
Journal Article
Closed access
JZJie Zhang
Jie Zhang
BDBruce Drinkwater
Bruce Drinkwater
PWPaul D. Wilcox
Paul D. Wilcox
AHAlan J. Hunter
Alan J. Hunter

28 May 2015 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
ZHZhenyu Hong
Zhenyu Hong
JZJie Zhang
Jie Zhang
BDBruce Drinkwater
Bruce Drinkwater
We observe distinct regimes of orbital angular momentum (OAM) transfer from two-dimensional Bessel-shaped acoustic vortices to matter. In a homogeneous diphasic mixture of microparticles and water, slow swirling about the vortex axis is seen. This effect is driven by the absorption of OAM across the mixture, the motion following the OAM density distribution. Larger particles are formed into clusters by the acoustic radiation force, making the mixture nonhomogeneous. Here, the OAM transfer to the microparticle clusters dominates and they spin at high speeds entraining the surrounding fluid.

7 October 2008 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JZJie Zhang
Jie Zhang
BDBruce Drinkwater
Bruce Drinkwater
PWPaul D. Wilcox
Paul D. Wilcox
Ultrasonic nondestructive evaluation is used for detection, characterization, and sizing of defects. The accurate sizing of defects that are of similar or less size than the ultrasonic wavelength is of particular importance in assessing structural integrity. In this paper, we demonstrate how measurement of the scattering coefficient matrix of a cracklike defect can be used to obtain its size, shape, and orientation. The scattering coefficient matrix describes the far field amplitude of scattered signals from a scatterer as a function of incident and scattering angles. A finite element (FE) modeling procedure is described that predicts the scattering coefficient matrix of various cracklike defects. Experimental results are presented using a commercial 64-element, 5 MHz array on 2 aluminum test samples that contain several machined slots and through thickness circular holes. To minimize the interference from the reflections of neighboring defects, a subarray approach is used to focus ultrasound on each target defect in turn and extract its scattering coefficient matrices. A circular hole and a fine slot can be clearly distinguished by their different scattering coefficient matrices over a specific range of incident angles and scattering angles. The orientation angles of slots directly below the array are deduced from the measured scattering coefficient matrix to an accuracy of a few degrees, and their lengths are determined with an error of 10%.

16 September 2010 in Journal of Nondestructive Evaluation
Verified
Journal Article
Closed access
PDF file
JZJie Zhang
Jie Zhang
BDBruce Drinkwater
Bruce Drinkwater
PWPaul D. Wilcox
Paul D. Wilcox

2 August 2013 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JZJie Zhang
Jie Zhang
BDBruce Drinkwater
Bruce Drinkwater
PWPaul D. Wilcox
Paul D. Wilcox
Ultrasonic array imaging algorithms have been widely used and developed in nondestructive evaluation in the last 10 years. In this paper, three imaging algorithms [total focusing method (TFM), phase-coherent imaging (PCI), and spatial compounding imaging (SCI)] are compared through both simulation and experimental measurements. In the simulation, array data sets were generated using a hybrid forward model containing a single defect among a multitude of randomly distributed point scatterers to represent backscatter from material microstructure. The number of point scatterers per unit area and their scattering amplitude were optimized to reduce computation cost. The SNR of the final images and their resolution were used to indicate the quality of the different imaging algorithms. The images of different types of defects (point reflectors and planar cracks) were used to investigate the robustness of the imaging algorithms. It is shown that PCI can yield higher image resolution and higher SNR for defects in material with weak backscatter than TFM, but that the images of cracks are distorted. Overall, TFM is the most robust algorithm across a range of different types of defects. It is also shown that the detection limit of all three imaging algorithms is almost equal for weakly scattering defects.

20 March 2006 in Journal of Tribology
Verified
Journal Article
Closed access
PDF file
JZJie Zhang
Jie Zhang
BDBruce Drinkwater
Bruce Drinkwater
Robert Dwyer-JoyceRobert Dwyer-Joyce
Robert Dwyer-Joyce
A lubricant-film monitoring system for a conventional deep groove ball bearing (type 6016, shaft diameter 80 mm, ball diameter 12.7 mm) is described. A high-frequency (50 MHz) ultrasonic transducer is mounted on the static outer raceway of the bearing. The transducer is focused on the ball-raceway interface and used to measure the reflection coefficient of the lubricant in the “contact” ellipse between bearing components. The reflection coefficient characterizes the lubricant film and can be used to calculate its thickness. An accurate triggering system enables multiple reflection measurements to be made as each lubricated contact moves past the measurement location. Experiments are described in which bearings were deliberately caused to fail by the addition of acetone, water, and sand to the lubricant. The ultrasonic reflection coefficient was monitored as a function of time as the failure occurred. Also monitored were the more standard parameters, temperature and vibration. The results indicate that the ultrasonic measurements are able to detect the failures before seizure. It is also observed that, when used in parallel, these monitoring techniques offer the potential to diagnose the failure mechanism and hence improve predictions of remaining life.