Frank Blumensaat

Dr. Frank Blumensaat

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

30 April 2019 in IEEE Access
Verified
Journal Article
Open access
CEChristian Ebi
Christian Ebi
FSFabian Schaltegger
Fabian Schaltegger
ARAndreas Rust
Andreas Rust
FBFrank Blumensaat
Frank Blumensaat
Collecting precise real-time information on urban drainage system performance is essential to identify, predict and manage critical loading situations, such as urban flash floods and sewer overflows. Although emerging low-power wireless communication techniques allow efficient data transfers with great above-ground performance, for underground or indoor applications a large coverage range is difficult to achieve due to physical and topological limitations, particularly in dense urban areas. In this paper, we first discuss range limitations of the LoRaWAN standard based on a systematic evaluation of a long-term operation of a sensor network monitoring in-sewer process dynamics. Analyses reveal an –. on average – five-fold higher data packet loss for sub-surface nodes, which steadily grows with increasing distance to the gateway. Secondly, we present a novel LPWAN concept based on the LoRa. technology that i) enhances transmission reliability, efficiency and flexibility in range-critical situations through meshed multi-hop routing, and ii) ensures a precise time-synchronization through optional GPS or DCF77 long-wave time signaling. We thirdly illustrate the usefulness of the newly developed concept by evaluating the radio transmission performance for two independent full-scale field tests. Test results show that the synchronous LoRa mesh network approach clearly outperforms the standard LoRaWAN technique with regard to the reliability of packet delivery when transmitting from range-critical locations. Hence, the approach is expected to generally ease data collection from difficult-to-access locations, such as underground areas.

14 March 2017 in Hydrology and Earth System Sciences
Verified
Journal Article
Open access
PDF file
NPNadav Peleg
Nadav Peleg
FBFrank Blumensaat
Frank Blumensaat
PMPeter Molnar
Peter Molnar
SFSimone Fatichi
Simone Fatichi
PBPaolo Burlando
Paolo Burlando
The performance of urban drainage systems is typically examined using hydrological and hydrodynamic models where rainfall input is uniformly distributed, i.e., derived from a single or very few rain gauges. When models are fed with a single uniformly distributed rainfall realization, the response of the urban drainage system to the rainfall variability remains unexplored. The goal of this study was to understand how climate variability and spatial rainfall variability, jointly or individually considered, affect the response of a calibrated hydrodynamic urban drainage model. A stochastic spatially distributed rainfall generator (STREAP – Space-Time Realizations of Areal Precipitation) was used to simulate many realizations of rainfall for a 30-year period, accounting for both climate variability and spatial rainfall variability. The generated rainfall ensemble was used as input into a calibrated hydrodynamic model (EPA SWMM – the US EPA's Storm Water Management Model) to simulate surface runoff and channel flow in a small urban catchment in the city of Lucerne, Switzerland. The variability of peak flows in response to rainfall of different return periods was evaluated at three different locations in the urban drainage network and partitioned among its sources. The main contribution to the total flow variability was found to originate from the natural climate variability (on average over 74 %). In addition, the relative contribution of the spatial rainfall variability to the total flow variability was found to increase with longer return periods. This suggests that while the use of spatially distributed rainfall data can supply valuable information for sewer network design (typically based on rainfall with return periods from 5 to 15 years), there is a more pronounced relevance when conducting flood risk assessments for larger return periods. The results show the importance of using multiple distributed rainfall realizations in urban hydrology studies to capture the total flow variability in the response of the urban drainage systems to heavy rainfall events.

29 July 2011 in Environmental Earth Sciences
Verified
Journal Article
Closed access
PDF file
FBFrank Blumensaat
Frank Blumensaat
MWMartin Wolfram
Martin Wolfram
PKPeter Krebs
Peter Krebs

1 October 2017 in Water Research
Verified
Journal Article
Open access
AMAnn-Kathrin McCall
Ann-Kathrin McCall
RPRocco Palmitessa
Rocco Palmitessa
FBFrank Blumensaat
Frank Blumensaat
EMEberhard Morgenroth
Eberhard Morgenroth
COChristoph Ort
Christoph Ort
To which extent illicit drugs are transformed during in-sewer transport, depends on a number of factors: i) substance-specific transformation rates, ii) environmental conditions, iii) point of discharge (location of drug user) and iv) sewer network properties, primarily hydraulic residence time (HRT) and the ratio of biofilm contact area to wastewater volume (A/Veq). Assessing associated uncertainties typically requires numerous simulations. Therefore, we propose a new two-step modeling framework: 1) Quantify hydrodynamic conditions. This computationally demanding step was performed once in SWMM to derive HRT and A/Veq for each potential point of discharge (node) in three catchments of different size. 2) Estimate biomarker loss. In this step, Monte Carlo simulations were performed for defined scenarios. Depending on assumptions about drug user distribution and prevalence, a number of nodes was sampled. For each node an empirical first-order transformation model was applied with flow-path-corresponding HRT and A/Veq from step 1. Biotic and abiotic transformation rates were sampled from distributions combining variability of different biofilms. In our modeling study, median losses were >30% for amphetamine, 6-monoacetylmorphine and 6-acetylcodeine in all three catchments with high uncertainty (5%-100% loss), which would imply a systematic underestimation of consumption when neglecting in-sewer processes. Median losses for 21 other investigated biomarkers were <10% with different uncertainty ranges - "no substantial transformation" was confirmed for nine substances in a real sewer segment with a 2-h residence time. Transferability of these results must be tested for other catchments. To further reduce uncertainty, mainly additional knowledge on transformation rates, particularly in biofilm, and their distribution across a sewer network is needed to update model input objectively. Our approach allows efficient testing and, furthermore, can be expanded for many other human biomarkers. Accounting for biomarker stability during in-sewer transport will avoid biased estimates and further improve wastewater-based epidemiology.

1 November 2021 in Water Research
Verified
Journal Article
Open access
SRStefania Russo
Stefania Russo
MBMichael D. Besmer
Michael D. Besmer
FBFrank Blumensaat
Frank Blumensaat
DBDamien Bouffard
Damien Bouffard
ADAndy Disch
Andy Disch
KVKris Villez
Kris Villez
Anomaly detection is the process of identifying unexpected data samples in datasets. Automated anomaly detection is either performed using supervised machine learning models, which require a labelled dataset for their calibration, or unsupervised models, which do not require labels. While academic research has produced a vast array of tools and machine learning models for automated anomaly detection, the research community focused on environmental systems still lacks a comparative analysis that is simultaneously comprehensive, objective, and systematic. This knowledge gap is addressed for the first time in this study, where 15 different supervised and unsupervised anomaly detection models are evaluated on 5 different environmental datasets from engineered and natural aquatic systems. To this end, anomaly detection performance, labelling efforts, as well as the impact of model and algorithm tuning are taken into account. As a result, our analysis reveals the relative strengths and weaknesses of the different approaches in an objective manner without bias for any particular paradigm in machine learning. Most importantly, our results show that expert-based data annotation is extremely valuable for anomaly detection based on machine learning.