Stefania Russo

Stefania Russo


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in Soft Robotics
Verified
Journal Article
Open access
SRStefania Russo
Stefania Russo
TRTommaso Ranzani
Tommaso Ranzani
HLHongbin Liu
Hongbin Liu
SNSamia Nefti-Meziani
Samia Nefti-Meziani
KAKaspar Althoefer
Kaspar Althoefer
AMArianna Menciassi
Arianna Menciassi
This article introduces a soft and stretchable sensor composed of silicone rubber integrating a conductive liquid-filled channel with a biocompatible sodium chloride (NaCl) solution and novel stretchable gold sputtered electrodes to facilitate the biocompatibility of the sensor. By stretching the sensor, the cross section of the channel deforms, thus leading to a change in electrical resistance. The functionalities of the sensor have been validated experimentally: changes in electrical resistance are measured as a function of the applied strain. The experimentally measured values match theoretical predictions, showing relatively low hysteresis. A preliminary assessment on the proposed sensor prototype shows good results with a maximum tested strain of 64%. The design optimization of the saline solution, the electrodes, and the algebraic approximations derived for integrating the sensors in a flexible manipulator for surgery has been discussed. The contribution of this article is the introduction of the biocompatible and stretchable gold sputtered electrodes integrated with the NaCl-filled channel rubber as a fully biocompatible solution for measuring deformations in soft and stretchable medical instruments.

31 August 2017 in Sensors
Verified
Journal Article
Open access
PDF file
SRStefania Russo
Stefania Russo
SNSamia Nefti-Meziani
Samia Nefti-Meziani
NCNicola Carbonaro
Nicola Carbonaro
Alessandro TognettiAlessandro Tognetti
Alessandro Tognetti
Electrical Impedance Tomography (EIT) is a medical imaging technique that has been recently used to realize stretchable pressure sensors. In this method, voltage measurements are taken at electrodes placed at the boundary of the sensor and are used to reconstruct an image of the applied touch pressure points. The drawback with EIT-based sensors, however, is their low spatial resolution due to the ill-posed nature of the EIT reconstruction. In this paper, we show our performance evaluation of different EIT drive patterns, specifically strategies for electrode selection when performing current injection and voltage measurements. We compare voltage data with Signal-to-Noise Ratio (SNR) and Boundary Voltage Changes (BVC), and study image quality with Size Error (SE), Position Error (PE) and Ringing (RNG) parameters, in the case of one-point and two-point simultaneous contact locations. The study shows that, in order to improve the performance of EIT based sensors, the electrode selection strategies should dynamically change correspondingly to the location of the input stimuli. In fact, the selection of one drive pattern over another can improve the target size detection and position accuracy up to 4.7% and 18%, respectively.

1 December 2020 in Environmental Modelling & Software
Verified
Journal Article
Open access
SRStefania Russo
Stefania Russo
MLMoritz Lürig
Moritz Lürig
WHWenjin Hao
Wenjin Hao
BMBlake Matthews
Blake Matthews
KVKris Villez
Kris Villez

1 November 2021 in Water Research
Verified
Journal Article
Open access
SRStefania Russo
Stefania Russo
MBMichael D. Besmer
Michael D. Besmer
FBFrank Blumensaat
Frank Blumensaat
DBDamien Bouffard
Damien Bouffard
ADAndy Disch
Andy Disch
KVKris Villez
Kris Villez
Anomaly detection is the process of identifying unexpected data samples in datasets. Automated anomaly detection is either performed using supervised machine learning models, which require a labelled dataset for their calibration, or unsupervised models, which do not require labels. While academic research has produced a vast array of tools and machine learning models for automated anomaly detection, the research community focused on environmental systems still lacks a comparative analysis that is simultaneously comprehensive, objective, and systematic. This knowledge gap is addressed for the first time in this study, where 15 different supervised and unsupervised anomaly detection models are evaluated on 5 different environmental datasets from engineered and natural aquatic systems. To this end, anomaly detection performance, labelling efforts, as well as the impact of model and algorithm tuning are taken into account. As a result, our analysis reveals the relative strengths and weaknesses of the different approaches in an objective manner without bias for any particular paradigm in machine learning. Most importantly, our results show that expert-based data annotation is extremely valuable for anomaly detection based on machine learning.

20 April 2022 in Nutrients
Verified
Journal Article
Open access
PDF file
SRStefania Russo
Stefania Russo
Stefano BonassiStefano Bonassi
Stefano Bonassi
Nutritional epidemiology employs observational data to discover associations between diet and disease risk. However, existing analytic methods of dietary data are often sub-optimal, with limited incorporation and analysis of the correlations between the studied variables and nonlinear behaviours in the data. Machine learning (ML) is an area of artificial intelligence that has the potential to improve modelling of nonlinear associations and confounding which are found in nutritional data. These opportunities notwithstanding, the applications of ML in nutritional epidemiology must be approached cautiously to safeguard the scientific quality of the results and provide accurate interpretations. Given the complex scenario around ML, judicious application of such tools is necessary to offer nutritional epidemiology a novel analytical resource for dietary measurement and assessment and a tool to model the complexity of dietary intake and its relation to health. This work describes the applications of ML in nutritional epidemiology and provides guidelines to avoid common pitfalls encountered in applying predictive statistical models to nutritional data. Furthermore, it helps unfamiliar readers better assess the significance of their results and provides new possible future directions in the field of ML in nutritional epidemiology.

26 July 2017 in Technologies
Verified
Journal Article
Open access
PDF file
SRStefania Russo
Stefania Russo
SNSamia Nefti-Meziani
Samia Nefti-Meziani
NCNicola Carbonaro
Nicola Carbonaro
Alessandro TognettiAlessandro Tognetti
Alessandro Tognetti
Electrical impedance tomography (EIT) is an imaging method that can be applied over stretchable conductive-fabric materials to realize soft and wearable pressure sensors through current injections and voltage measurements at electrodes placed at the boundary of a conductive medium. In common EIT systems, the voltage data are serially measured by means of multiplexers, and are hence collected at slightly different times, which affects the real-time performance of the system. They also tend to have complicated hardware, which increases power consumption. In this paper, we present our design of a 16-electrode high-speed EIT system that simultaneously implements constant current injection and differential potential measurements. This leads to a faster, simpler-to-implement and less-noisy technique, when compared with traditional EIT approaches. Our system consists of a Howland current pump with two multiplexers for a constant DC current supply, and a data acquisition card. It guarantees a data collection rate of 78 frames/s. The results from our conductive stretchable fabric sensor show that the system successfully performs voltage data collection with a mean signal-to-noise ratio (SNR) of 55 dB, and a mean absolute deviation (MAD) of 0.5 mV. The power consumption can be brought down to 3 mW; therefore, it is suitable for battery-powered applications. Finally, pressure contacts over the sensor are properly reconstructed, thereby validating the efficiency of our EIT system for soft and stretchable sensor applications.