Marianne Hollensteiner

Dr. Marianne Hollensteiner


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Injury
Verified
Journal Article
Open access
PAPeter Augat
Peter Augat
MHMarianne Hollensteiner
Marianne Hollensteiner
CRChristian von Rüden
Christian von Rüden
The biomechanical environment plays a dominant role in the process of fracture repair. Mechanical signals control biological activities at the fracture site, regulate the formation and proliferation of different cell types, and are responsible for the formation of connective tissues and the consolidation of the fractured bone. The mechanobiology at the fracture site can be easily manipulated by the design and configuration of the fracture fixation construct and by the loading of the extremity (weight-bearing prescription). Depending on the choice of fracture fixation, the healing response can be directed towards direct healing or towards indirect healing through callus formation. This manuscript summarizes the evidence from experimental studies and clinical observations on the effect of mechanical manipulation on the healing response. Parameters like fracture gap size, interfragmentary movement, interfragmentary strain, and axial and shear deformation will be explored with respect to their respective effects on fracture repair. Also, the role of externally applied movement on the potential enhancement on the fracture repair process will be explored. Factors like fracture gap size, type and amplitude of the mechanical deformation as well as the loading history and its timing will be discussed.

1 August 2017 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
MHMarianne Hollensteiner
Marianne Hollensteiner
DFDavid Fürst
David Fürst
BEBenjamin Esterer
Benjamin Esterer
PAPeter Augat
Peter Augat
FSFalk Schrödl
Falk Schrödl
ASAndreas Schrempf
Andreas Schrempf

1 May 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
MHMarianne Hollensteiner
Marianne Hollensteiner
SSSabrina Sandriesser
Sabrina Sandriesser
SHSimon Hackl
Simon Hackl
PAPeter Augat
Peter Augat

1 October 2022 in Foot and Ankle Surgery
Verified
Journal Article
Open access
MHMarianne Hollensteiner
Marianne Hollensteiner
SSSabrina Sandriesser
Sabrina Sandriesser
HKHilmar Krauss
Hilmar Krauss
MGMarkus Greinwald
Markus Greinwald
FSFabian Stuby
Fabian Stuby
PAPeter Augat
Peter Augat
A common agreement for the surgical treatment of osteoporotic ankle fractures has not been defined yet although locking plates are preferred for fractures with poor bone quality. This study aims to evaluate the mechanical stability of locked and conventional plates on osteoporotic Danis-Weber-B-fibula fracture models. Fractured custom-made osteoporotic fibulae were treated with neutralization plate plus lag screw, locking plate plus lag screw, or a standalone locking plate. Load until failure was applied mimicking single-leg stance. Stiffness, failureload, and interfragmentary movements were investigated. Stiffness, failureload and axial fragment movement showed no significant differences among groups. Shear movements and fragment rotation around the shaft of the neutralization plate were on average twice as high as those of the locking plates. Although no superiority was shown for overall mechanical performance, the locking plate groups exhibited higher shear and rotational stability than the neutralization plate.

Verified
Journal Article
Open access
PDF file
MHMarianne Hollensteiner
Marianne Hollensteiner
SSSabrina Sandriesser
Sabrina Sandriesser
FRFelix Rittenschober
Felix Rittenschober
JHJosef Hochreiter
Josef Hochreiter
PAPeter Augat
Peter Augat
ROReinhold Ortmaier
Reinhold Ortmaier
Background: Acromial Levy III fractures after inverse shoulder arthroplasty occur in up to 7% of patients. To date, it is not clear how these fractures should be treated as clinical outcomes remain unsatisfactory. The aim of this study was to evaluate the biomechanical performance of three different plating methods of type III acromion fractures. Methods: Levy III fractures in synthetic scapulae were fixed with three different methods. Angular stable locking plates were placed on the spina scapula to bridge the fracture either dorsally, caudally, or on both aspects by double plating. In a biomechanical experiment, the pull of the deltoid muscle at 40° abduction of the arm was simulated by cyclic loading with increasing load levels until failure. Failure load, cycles to failure, and fragment motions were evaluated. Results: The results showed that double plating (350 ± 63 N) withstood the highest loads until failure, followed by dorsal (292 ± 20 N) and caudal (217 ± 49 N) plating. Similarly, double plating showed significantly smaller fragment movement than the other two groups. Conclusions: Double plating appeared to provide the largest biomechanical stability in type III acromion fracture under arm abduction. Caudal plating in contract resulted in insufficient fracture stability and early failure and can thus not be recommended from a biomechanical point of view.

1 October 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
BEBenjamin Esterer
Benjamin Esterer
MHMarianne Hollensteiner
Marianne Hollensteiner
ASAndreas Schrempf
Andreas Schrempf
MWMartin Winkler
Martin Winkler
SGStefan Gabauer
Stefan Gabauer
PAPeter Augat
Peter Augat
The force experienced while inserting an 18-gauge Tuohy needle into the epidural space or dura is one of only two feedback components perceived by an anaesthesiologist to deduce the needle tip position in a patient's spine. To the best of the authors knowledge, no x-ray validated measurements of these forces are currently available to the public. A needle insertion force recording during an automated insertion of an 18-gauge Tuohy needle into human vertebral segments of four female donors was conducted. During the measurements, x-ray images were recorded simultaneously. The force peaks due to the penetration of the ligamentum supraspinale and ligamentum flavum were measured and compared to the measurements of an artificial patient phantom for a hybrid patient simulator. Based on these force peaks and the slope of the ligamentum interspinale, a mathematical model was developed. The model parameters were used to compare human specimens and artificial patient phantom haptics. The force peaks for the ligamenta supraspinale and flavum were 7.55 ± 3.63 N and 15.18 ± 5.71 N, respectively. No significant differences were found between the patient phantom and the human specimens for the force peaks and four of six physical model parameters. The patient phantom mimics the same resistive force against the insertion of an 18-gauge Tuohy needle. However, there was a highly significant (p < 0.001, effsize = 0.949 and p < 0.001, effsize = 0.896) statistical difference observed in the insertion depth where the force peaks of the ligamenta supraspinale and flavum were detected between the measurements on the human specimens and the patient phantom. Within this work, biomechanical evidence was identified for the needle insertion force into human specimens. The comparison of the measured values of the human vertebral segments and the artificial patient phantom showed promising results.