Quang Huy Tran

Dr. Quang Huy Tran

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
QTQuang Huy Tran
Quang Huy Tran
DHDongyeob Han
Dongyeob Han
CKChoonghyun Kang
Choonghyun Kang
AHAchintya Haldar
Achintya Haldar
Jungwon HuhJungwon Huh
Jungwon Huh
Active thermal imaging is an effective nondestructive technique in the structural health monitoring field, especially for concrete structures not exposed directly to the sun. However, the impact of meteorological factors on the testing results is considerable and should be studied in detail. In this study, the impulse thermography technique with halogen lamps heat sources is used to detect defects in concrete structural components that are not exposed directly to sunlight and not significantly affected by the wind, such as interior bridge box-girders and buildings. To consider the effect of environment, ambient temperature and relative humidity, these factors are investigated in twelve cases of testing on a concrete slab in the laboratory, to minimize the influence of wind. The results showed that the absolute contrast between the defective and sound areas becomes more apparent with an increase of ambient temperature, and it increases at a faster rate with large and shallow delaminations than small and deep delaminations. In addition, the absolute contrast of delamination near the surface might be greater under a highly humid atmosphere. This study indicated that the results obtained from the active thermography technique will be more apparent if the inspection is conducted on a day with high ambient temperature and humidity.

18 July 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jungwon HuhJungwon Huh
Jungwon Huh
QTQuang Huy Tran
Quang Huy Tran
AHAchintya Haldar
Achintya Haldar
IPInnjoon Park
Innjoon Park
JAJin-Hee Ahn
Jin-Hee Ahn
Tunnels, culverts, and subway stations are the main parts of an integrated infrastructure system. Most of them are constructed by the cut-and-cover method at shallow depths (mainly lower than 30 m) of soil deposits, where large-scale seismic ground deformation can occur with lower stiffness and strength of the soil. Therefore, the transverse racking deformation (one of the major seismic ground deformation) due to soil shear deformations should be included in the seismic design of underground structures using cost- and time-efficient methods that can achieve robustness of design and are easily understood by engineers. This paper aims to develop a simplified but comprehensive approach relating to vulnerability assessment in the form of fragility curves on a shallow two-story reinforced concrete underground box structure constructed in a highly-weathered soil. In addition, a comparison of the results of earthquakes per peak ground acceleration (PGA) is conducted to determine the effective and appropriate number for cost- and time-benefit analysis. The ground response acceleration method for buried structures (GRAMBS) is used to analyze the behavior of the structure subjected to transverse seismic loading under quasi-static conditions. Furthermore, the damage states that indicate the exceedance level of the structural strength capacity are described by the results of nonlinear static analyses (or so-called pushover analyses). The Latin hypercube sampling technique is employed to consider the uncertainties associated with the material properties and concrete cover owing to the variation in construction conditions. Finally, a large number of artificial ground shakings satisfying the design spectrum are generated in order to develop the seismic fragility curves based on the defined damage states. It is worth noting that the number of ground motions per PGA, which is equal to or larger than 20, is a reasonable value to perform a structural analysis that produces satisfactory fragility curves.

2 December 2019 in Materials
Verified
Journal Article
Open access
PDF file
Van Ha MacVan Ha Mac
Van Ha Mac
QTQuang Huy Tran
Quang Huy Tran
Jungwon HuhJungwon Huh
Jungwon Huh
Nhu Son DoanNhu Son Doan
Nhu Son Doan
CKChoonghyun Kang
Choonghyun Kang
DHDongyeob Han
Dongyeob Han
In bridge structures, concrete decks have a higher risk of damage than other components owing to the direct impact of traffic. This study aims to develop a comprehensive system for bridge inspection using passive infrared thermography (IRT). Experiments were conducted on a concrete specimen (assumed as the surface of the bridge deck) embedded artificial delaminations with different width-to-depth ratios (WTDRs). Both professional handheld IR camera (H-IRC) and a UAV mounted with an IR camera (UAV-IRC) were employed simultaneously to capture the surface temperature of the structure. The present work indicates that the passive IRT technique with an H-IRC can be used to detect delaminations located at depths of 4 cm or less from the structure surface if the WTDRs are not lesser than 1.9 for daytime and 2.5 for nighttime when testing on a sunny day. In addition, the larger the WTDR, the higher the temperature difference can be produced, thus delaminations could be observed more clearly. Furthermore, our study suggests that the concrete bridge deck inspection using passive IRT can produce appropriate results if the inspection is performed from 10:00 to 15:00 or from 19:30 to approximately 2:00 on a sunny day. Good agreement between the results obtained from tests using H-IRC and UAV-IRC was observed, which validates the application of UAV-IRC in real structure inspection.

1 January 2016 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
Jungwon HuhJungwon Huh
Jungwon Huh
QTQuang Huy Tran
Quang Huy Tran
JLJong-Han Lee
Jong-Han Lee
DHDongYeob Han
DongYeob Han
JAJin-Hee Ahn
Jin-Hee Ahn
SYSolomon Yim
Solomon Yim
Concrete is certainly prone to internal deteriorations or defects during the construction and operating periods. Compared with other nondestructive techniques, infrared thermography can easily detect the subsurface delamination in a very short period of time, but accurately identifying its size and depth in concrete is a very challenging task. In this study, experimental testing was carried out on a concrete specimen having internal delaminations of various sizes and at varying depths. Delaminations at 1 and 2 cm deep showed a good temperature contrast after only 5-minute heating, but delaminations at 3 cm practically identified the value of the temperature contrast from heating of 15 minutes. In addition, the size of the delamination at 3 cm deep could be estimated with a difference of 10% to 28% for 20 minutes of heating. The depth of the delamination was linearly correlated with the increase in its size.

30 April 2018 in Journal of Nondestructive Evaluation
Verified
Journal Article
Closed access
PDF file
QTQuang Huy Tran
Quang Huy Tran
Jungwon HuhJungwon Huh
Jungwon Huh
CKChoonghyun Kang
Choonghyun Kang
Bang Yeon LeeBang Yeon Lee
Bang Yeon Lee
IKIn-Tae Kim
In-Tae Kim
JAJin-Hee Ahn
Jin-Hee Ahn

19 October 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jungwon HuhJungwon Huh
Jungwon Huh
Van Ha MacVan Ha Mac
Van Ha Mac
QTQuang Huy Tran
Quang Huy Tran
KLKiyeol Lee
Kiyeol Lee
JLJong-In Lee
Jong-In Lee
CKChoonghyun Kang
Choonghyun Kang
Detecting subsurface delamination is a difficult and vital task to maintain the durability and serviceability of concrete structure for its whole life cycle. The aim of this work was to obtain better knowledge of the effect of depth, heating time, and rebar on the detectability capacity of delamination. Experimental tests were carried out on a concrete specimen in the laboratory using Long Pulsed Thermography (LPT). Six halogen lamps and a long wavelength infrared camera with a focal plane array of 640 × 480 pixels were used as the heat source and infrared detector, respectively. The study focused on the embedded imitation delaminations with the size of 10 cm × 10 cm × 1 cm, located at depths varying from 1 to 8 cm. The signal-to-noise ratio (SNR) was applied as a criterion to assess the detectability of delamination. The results of this study indicate that as the provided heating time climbed, the SNR increased, and the defect could be identified more clearly. On the other hand, when using the same heating regime, a shallow delamination displayed a higher SNR than a deeper one. The moderate fall of the SNR in the case of imitating defect located below reinforced steel was also observed. The absolute contrast was monitored to determine the observation time, and the nondimensional prefactor k was empirically proposed to predict the depth of delamination. The mean absolute percentage error (MAPE) was used to quantitatively evaluate the difference between forecasted and real depth, which evaluation confirmed the high reliability of the estimated value of the prefactor k.