In recent years, wearable e-skin has emerged as a prominent technology with a wide range of applications in healthcare, health surveillance, human-machine interface, and virtual reality. Inspired by the properties of human skin, arrayed wearable e-skin is a novel technology that offers multifunctional sensing capabilities. It can detect and quantify various stimuli, mimicking the human somatosensory system, and record a wide range of physical and physiological parameters in real time. By combining flexible electronic device units with a data acquisition system, specific functional sensors can be distributed in targeted areas to achieve high sensitivity, resolution, adjustable sensing range, and large-area expandability. This review provides a comprehensive overview of recent advances in wearable e-skin technology, including its development status, types of applications, power supply methods, and prospects for future development. The emphasis of current research is on enhancing the sensitivity and stability of sensors, improving the comfort and reliability of wearable devices, and developing intelligent data processing and application algorithms. This review aims to serve as a scientific reference for the intelligent development of wearable e-skin technology.
The variable displacement pump control system has greater energy-saving advantages and application prospects than the valve control system. However, the variable displacement pump control of differential cylinder is not concurrent with the existing technologies. The asymmetric pump-controlled cylinder is, therefore, used to balance the unequal volume flow through a single rod cylinder in closed-circuit system. This is considered to be an effective method. Nevertheless, the asymmetric axial piston pump (AAPP) is a constant displacement pump. In this study, variable-displacement asymmetric axial piston pump (VAPP) is investigated according to the same principle used in investigating AAPP. This study, therefore, aims at investigating the characteristics of VAPP. The variable-displacement output of VAPP is implemented by controlling the swash plate angle with angle feedback control circuit, which is composed of a servo proportional valve and an angular displacement sensor. The angular displacement sensor is connected to the swash plate. The simulation model of VAPP, which is set up through the ITI-SimulationX simulation platform, is used to predict VAPP’s characteristics. The purpose of implementing the experiment is to verify the theoretical results. Both the simulation and the experiment results demonstrated that the swash plate angle is controlled by a variable mechanism; when the swash plate angle increases, the flow of Port B and Port T increases while the response speed of Port B and Port T also accelerates. When the swash plate angle is constant, the flow of Port B and Port T increases along with the increase of pump speed, although the pressure-response speed of Port B is faster than that of Port T. Consequently, the flow pulsation of Port B and Port T tends to decrease gradually along with the increase of pump speed. When the pressure loaded on Port B equals to that of Port T, the flow ripple cycle of Port B is longer than that of Port T, whereas the peak flow of Port B is higher than that of Port T. Since the flow ripple of Port T is bigger than that of Port B, Port T should be connected to the low pressure sides or the oil tank so that it does not affect VAPP’s performance. Further, to avoid the backflow of VAPP from Port T to Port B, Port T cannot be loaded alone, and the loading pressure of Port T also cannot exceed that of Port B.
4 December 2021 in Chinese Journal of Mechanical Engineering
The tribological properties of cylinder block/valve plate is an important consideration in the design of axial piston pump. The effect of materials and heat treatment on friction and wear properties has been studied in depth. Engineering experiences show that the speed and load also affect the tribological properties, but these have not been systematically analyzed. The purpose of this paper is to evaluate the tribological properties of the commonly used materials (CuPb15Sn5 and 38CrMoAl/42CrMo) for cylinder block/valve plate with different heat treatment and contact pressure at different speed. During the test, tribometer is used to simulate the contact pattern between the valve plate/cylinder block in axial piston pump, the friction coefficient, wear rate and surface topography are analyzed to evaluate the tribological properties of different types of friction samples at different speed. Results indicate that: (1) contact surface of the samples at 1800 r/min is more prone to adhesive wear than those at 500 r/min; (2) in the terms of wear resistance, quench-tempered and nitrided 38CrMoAl (38CrMoAl QTN for short) is better than quench-tempered and nitrided 42CrMo, although they are all commonly used materials in the axial piston pump; (3) 2.5 MPa is the critical contact pressure of the interface between valve plate made of 38CrMoAl QTN and cylinder block made of CuPb15Sn5 on the tribometer, which implies the pressure bearing area at the bottom of the cylinder block should be carefully designed; (4) the valve plate/cylinder block made of 38CrMoAl QTN/CuPb15Sn5 exhibits good tribological properties in a real axial piston pump. This research is useful for the failure analysis and structural optimization design of the valve plates/cylinder block.
14 December 2017 in Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering
In digital fluid power, fast switching valve is a potential digital hydraulic component because of less throttling loss, reliability, low price, and so on. But its outlet flow is usually small and discontinuous. In this article, a two-stage proportional flow control valve is presented, in which the main stage is a flow amplifying valve, and the pilot stage consists of several switching valves with pulse width modulation control strategy. Peak and hold technique is adopted to improve the dynamic performance of the pilot stage. Benefits of the proposed configuration are continuous outlet flow and large flow capacity. The valve performance is investigated by theoretical analysis, simulation, and test. It is shown that both poppet displacement and outlet flow fluctuate around a stable value because of the discontinuous pilot flow, but the average outlet flow as well as poppet displacement of the main stage can be approximately proportionally regulated by changing pulse width modulation duty ratio. Average outlet flow of the main stage is an amplification of that of pilot stage. Increasing the average pressure drop not only increases outlet flow but also increases the severity of flow pulsations because pressure fluctuation becomes more serious as the average pressure difference increases. In theory, higher carrier frequency leads to smoother outflow; however, tested outflow profile of the proposed valve at 50 Hz is not significantly smoother than that at 30 Hz. This phenomenon may be due to the asynchrony of the four switching valves and the pressure fluctuations during the testing process.