Yang Qu

Mr. Yang Qu

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2022 in Electronics
Verified
Journal Article
Open access
PDF file
YLYan Liu
Yan Liu
YMYan-Hua Ma
Yan-Hua Ma
ZYZhaojie Yu
Zhaojie Yu
SLShanshan Lou
Shanshan Lou
YQYang Qu
Yang Qu
YCYuchun Chang
Yuchun Chang
As the device feature size shrinks, the dissipation of power increases and further raises the carrier and lattice temperature, which finally affects device performance. In this paper, we analyze the comprehensive influence of the self-heating effect and hot carrier injection (HCI) using TCAD simulations. Based on the hydrodynamic and thermodynamic models, it is demonstrated that the thermal surface resistance had a positive impact on the carrier and lattice temperature and that the drain saturation current is reduced dramatically due to the self-heating effect. Moreover, the impact of HCI on device performance is discussed. Finally, it is concluded that the self-heating effect exacerbates the influence of HCI on device characteristics.

9 December 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YQYang Qu
Yang Qu
QZQing Zang
Qing Zang
ZLZehao Li
Zehao Li
QJQian Jiang
Qian Jiang
YLYang Liu
Yang Liu
YCYuchun Chang
Yuchun Chang
With the development of semiconductor fabrication technology, in 180 nm CMOS image sensor (CIS) process, the gap between two gates has been reduced to 0.25 μm. Under this background, charge transfer between gates is realized, like the process in charge-coupled devices (CCD). In recent literatures, skipper technology has been utilized to improve the noise performance of CIS as it was previously applied in CCDs. In this paper, a dual-channel readout low noise CIS based on skipper technology is proposed. Theoretical analysis is introduced to verify the advantages of skipper multiple sampling (SMS), compared with correlated multiple sampling (CMS). TCAD simulations were conducted to clarify the relationship between gate voltage level and the charge accommodation capacity and investigate the charge transfer efficiency (CTE) of the proposed pixel. An optimized pipeline readout chain is introduced to eliminate correlated noise and a post-simulation is implemented to study the readout circuit. According to the simulation results, the CTE improvement in the proposed skipper pixel is proved. By means of circuit-level simulations, the linearity of PGA and the input-referred noise (IRN) at different gains were obtained. Compared with conventional skipper structure, the pixel architecture proposed in this paper realizes the same noise level with half number of charge transfers, which mitigates the effect of CTE and improve the frame rate.

24 June 2023 in BMC Primary Care
Verified
Journal Article
Open access
PDF file
Yun WangYun Wang
Yun Wang
JZJianwei Zheng
Jianwei Zheng
TSTodd Schneberk
Todd Schneberk
YKYu Ke
Yu Ke
ACAlexandre Chan
Alexandre Chan
MNMichael B. Nichol
Michael B. Nichol
Primary care physicians (PCPs) play an indispensable role in providing comprehensive care and referring patients for specialty care and other medical services. As the COVID-19 outbreak disrupts patient access to care, understanding the quality of primary care is critical at this unprecedented moment to support patients with complex medical needs in the primary care setting and inform policymakers to redesign our primary care system. The traditional way of collecting information from patient surveys is time-consuming and costly, and novel data collection and analysis methods are needed. In this review paper, we describe the existing algorithms and metrics that use the real-world data to qualify and quantify primary care, including the identification of an individual’s likely PCP (identification of plurality provider and major provider), assessment of process quality (for example, appropriate-care-model composite measures), and continuity and regularity of care index (including the interval index, variance index and relative variance index), and highlight the strength and limitation of real world data from electronic health records (EHRs) and claims data in determining the quality of PCP care. The EHR audits facilitate assessing the quality of the workflow process and clinical appropriateness of primary care practices. With extensive and diverse records, administrative claims data can provide reliable information as it assesses primary care quality through coded information from different providers or networks. The use of EHRs and administrative claims data may be a cost-effective analytic strategy for evaluating the quality of primary care.

3 September 2024 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
YQYang Qu
Yang Qu
HLHongwei Liang
Hongwei Liang
SLShanshan Lou
Shanshan Lou
GZGuoqiang Zhong
Guoqiang Zhong
CYCheng Yu
Cheng Yu
YCYuchun Chang
Yuchun Chang
In this article, a noise improvement and dynamic range (DR) enhanced CMOS image sensor (CIS), using a shift biasing structure, is proposed. The shift biasing pixel is constructed from a conventional 4T pixel and three additional transistors, including a bias transistor (BT) and two switch transistors. The BT works as a switch to connect the source and drain to accumulate electrons in the source follower (SF) in shift biasing mode and provides an extra capacitance to enlarge the capacity of floating diffusion (FD) in low gain (LG) mode. Electron distribution and noise performance of SF are simulated to prove the function of shift biasing pixels. A prototype sensor, with a 512 $\times$ 128-pixel array, is fabricated with a 180 nm CIS process. Measurement shows a temporal noise of 2 e $^{{-}}$ is achieved, which is a 2 e $^{{-}}$ noise improvement compared with the reference 4T readout mode of shift biasing pixel. Additionally, an over 92 dB DR is realized by combining shift biasing mode and LG mode without any specific process or complex control circuits.