Jan Frymus

Dr. Jan Frymus

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2023 in Animals
Verified
Journal Article
Open access
PDF file
JFJan Frymus
Jan Frymus
PTPiotr Trębacz
Piotr Trębacz
AKAleksandra Kurkowska
Aleksandra Kurkowska
MPMateusz Pawlik
Mateusz Pawlik
ABAnna Barteczko
Anna Barteczko
MGMarek Galanty
Marek Galanty
Laparotomic attenuation of an intrahepatic portosystemic shunt (IHPSS) is more difficult than an extrahepatic one, and results in a higher risk of complications because the identification of the aberrant vessel in the liver remains often a challenge. Excessive preparation and traction of the parenchyma results in trauma, bleeding, and prolonged surgery, which is what worsens the prognosis. Therefore, based on computed tomographic angiography, we printed 3-dimensional (3D) individual patient liver models, scaled 1:1, and used them for surgery planning and as a guide during intraoperative identification of the shunt in four dogs with IHPSS. The advantages of the 3D technology are simple and precise planning of the surgery, fast intraoperative identification of the shunt, and low invasive dissection of the liver parenchyma. We conclude that 3D technology can potentially raise the recovery rate. To the best of our knowledge, this was the first application of 3D models in the surgery of canine IHPSS.

13 February 2025 in Animals
Verified
Journal Article
Open access
PDF file
PTPiotr Trębacz
Piotr Trębacz
JFJan Frymus
Jan Frymus
MPMateusz Pawlik
Mateusz Pawlik
ABAnna Barteczko
Anna Barteczko
AKAleksandra Kurkowska
Aleksandra Kurkowska
Michał CzopowiczMichał Czopowicz
Michał Czopowicz
The medial approach is a traditional portal during elbow arthroscopy. Some researchers have suggested that the caudo-medial arthroscopic approach allows better visualization of the medial and caudal elbow compartments. Such a portal is created caudally to the medial humeral epicondyle’s caudal aspect in the ulnar nerve’s vicinity. Therefore, we investigated the risk of ulnar nerve injury following the caudo-medial portal placement in 30 canine cadavers. After the telescope was inserted, an incision was made to visualize the nerve, and the distance between the cannula and the nerve was measured. An injury was diagnosed when the telescope at least scratched the nerve. The distance between the arthroscopic cannula and the ulnar nerve ranged from 0 to 8.0 mm (median: 0.5 mm) in 60 joints. Nerve injury occurred in 16/30 dogs (53%; CI 95%: 36%, 70%)—in 11 unilaterally and 5 bilaterally. In addition, in eight dogs, the cannula directly touched the nerve, creating a high risk of trauma. In total, nerve injury or high risk of trauma occurred in 21/30 dogs (70%; CI 95%: 52%, 83%). Ulnar nerve injury during caudo-medial arthroscopic portal creation appears common.

6 February 2024 in Animals
Verified
Journal Article
Open access
PDF file
PTPiotr Trębacz
Piotr Trębacz
JFJan Frymus
Jan Frymus
ABAnna Barteczko
Anna Barteczko
MPMateusz Pawlik
Mateusz Pawlik
AKAleksandra Kurkowska
Aleksandra Kurkowska
Michał CzopowiczMichał Czopowicz
Michał Czopowicz
(1) Background: Anatomically pre-contoured plates usually require only minimal or even no intraoperative contouring. For complex cases, such plates also assist the surgeon as an anatomical template during fracture reduction. In this study, we present our experience of using a 3D printing technology for the treatment of bicondylar humeral fractures in feline cadavers. (2) Methods: Surgeries were performed on 15 pairs of front limbs amputated at the scapula. The limbs were obtained from 15 adult cats without obvious pathology of the skeleton. After flexion of the elbow and subperiosteal elevation of the anconeus muscle, the humeral Y-T fractures were created using a bone chisel and mallet. A custom-made anatomically pre-contoured interlocking plate was used to reduce and stabilise the medial aspect of the humeral condyle to the humeral diaphysis. After reduction of the humeral condyle, a positional locking screw was then inserted from the medial to the lateral side and a straight 2.4/2.7 interlocking bone plate was used to stabilise the lateral part of the condyle to the humeral diaphysis. (3) Results: The length of the humerus ranged from 98.2 to 107.0 mm and did not differ significantly between the left and right bone. The diameter of the isthmus of the humeral condyle ranged from 5.2 to 5.5 mm and did not differ significantly between the left and right bone. In all 30 limbs, bicondylar fracture was accompanied by epicondylar comminution. In 7/30 limbs (4 left, 3 right) the fracture of the humeral shaft was also present. In the left limbs, the postoperative articular surface defect of the humeral condyle was small (2 mm) in 2/15 cases in which the condylar screw was incorrectly inserted. In the right limbs, the postoperative articular surface defect of the humeral condyle was small (<1 mm) in 14/15 cases and moderate (1–2 mm) in 1 case. (4) Conclusions: 3D printing and the technology of metal powder sintering offers a wide range of possibilities for the development of new surgical implants. The anatomically pre-contoured bone plate appears to be a valuable tool in the reduction and stabilisation of Y-T humeral fractures in adult domestic cats weighing 3.0 to 4.5 kg.

23 December 2023 in Animals
Verified
Journal Article
Open access
PDF file
PTPiotr Trębacz
Piotr Trębacz
JFJan Frymus
Jan Frymus
MPMateusz Pawlik
Mateusz Pawlik
ABAnna Barteczko
Anna Barteczko
AKAleksandra Kurkowska
Aleksandra Kurkowska
WKWojciech Kajzer
Wojciech Kajzer
The aim of this study was to compare the degree of visibility of the lateral and medial menisci before and after tibial plateau leveling osteotomy (TPLO) on 3D-printed models created after laser scanning of the right tibia with menisci derived from a fresh cadaver of a 4-year-old adult male golden retriever. The models were produced of white polylactic acid, and the menisci were filled with light-curing red resin. The models showed a similar conformation as the natural specimen harvested from the cadaver, maintaining the same length and width, in addition to reproducing the anatomical structures. From the pre- and post-TPLO radiographs, it was possible to identify the anatomical structures corresponding to the tibial plateau. The preoperative tibial plateau angle was 26.2°, and the postoperative one ranged between 4.0° and 5.3° (4.6 ± 0.4°). In the bird’s-eye photo, the total number of red pixels in the lateral and the medial meniscus was 2,053,995 and 2,140,939, respectively. Before TPLO, only between 14% and 19% of the entire area of the menisci was visible, and the unhidden part of the entire area of the meniscus before TPLO did not differ significantly between the lateral (16.2 ± 1.6%) and the medial (16.4 ± 1.6%) meniscus (p = 0.351). The visible part of the entire meniscus area increased significantly after TPLO both in the lateral and medial menisci (p < 0.001)—mean difference ± SD of 30.3 ± 4.3% (CI 95%: 27.9%, 32.6%) and 36.4 ± 6.4% (CI 95%: 32.9%, 40.0%), respectively. In conclusion, the intraoperative examination and treatment of dog menisci are easier after TPLO.

9 August 2023 in Animals
Verified
Journal Article
Open access
PDF file
PTPiotr Trębacz
Piotr Trębacz
JFJan Frymus
Jan Frymus
MGMarek Galanty
Marek Galanty
A suitable wound retraction is crucial for open surgical treatment of chylothorax in dogs. A single paracostal approach for transabdominal/transdiaphragmatic thoracic duct ligation and cisterna chyli ablation is an effective procedure. For the procedure, the use of stay sutures and handheld or automatic soft tissue retractors is recommended. However, it is often necessary to adjust the retractors several times during the surgery to provide sufficient exposure of the thoracic duct. This prolongs the operation and increases infection risk. In this report, we describe the modified application of two o-ring elastic wound retractors (O-WRs) in three large breed dogs with idiopathic chylothorax. We conclude that the O-WRs provide a static circumferential vision of the operation field and good access to the cisterna chyli, especially to the thoracic duct. The usage of other surgical instruments is not hampered by the O-WRs, and the elastic rings are not damaged by the metal instruments. Once placed in the diaphragmatic area, indeed, they do not require further manual retraction.

4 May 2024 in Animals
Verified
Journal Article
Open access
PDF file
PTPiotr Trębacz
Piotr Trębacz
JFJan Frymus
Jan Frymus
MPMateusz Pawlik
Mateusz Pawlik
ABAnna Barteczko
Anna Barteczko
AKAleksandra Kurkowska
Aleksandra Kurkowska
Michał CzopowiczMichał Czopowicz
Michał Czopowicz
(1) Background: Due to the unique structural and functional characteristics of the forelimb in cats, fractures of the radius and ulna are best repaired using internal fixation and stabilization in accordance with AO principles. This study presents the results of reduction of 42 cadaveric comminuted feline radial fractures reduced by minimally invasive plate osteosynthesis (MIPO). (2) Methods: Radius fractures were created on 21 pairs of forelimbs with intact bones. MIPO was then performed using two locking bone plates pre-contoured on 3D-printed bone models of the antebrachium of a male and a female cat. Pre- and postoperative radiographs were taken, and radius length and anatomical lateral distal radial angle (aLDRA) were measured. (3) Results: All fractures were classified as complex diaphyseal fractures of the radius. The radial bone length did not change significantly after surgery (F1,18 = 0.01, p = 0.933). However, the aLDRA was modified after surgery (F1,18 = 7.51, p = 0.013), but this change was only observed in females, in whom the aLDRA was significantly reduced (p = 0.035) compared to the value determined by the shape of the plate. In males, the pre- and postoperative aLDRA values were similar (p = 0.824). In 40 cases, alignment, adjacency of bone fragments, and apparatus were judged to be satisfactory. In two cases, the plate was fixed to the proximal radius and distal ulna due to misidentification of the distal radius. In both cases, revision surgery and correct fixation of the radius gave proper alignment, adjacency, and apparatus. (4) Conclusion: A pre-contoured plate on a 3D-printed model of the male and female domestic cat antebrachium was suitable for the reduction and stabilization of comminuted radial fractures in a cohort of domestic cat cadavers without the need to print individual antebrachial bone models for each patient.