Wojciech Kajzer

Dr. Wojciech Kajzer

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
MBMarcin Basiaga
Marcin Basiaga
WKWojciech Kajzer
Wojciech Kajzer
WWWitold Walke
Witold Walke
AKAnita Kajzer
Anita Kajzer
MKMarcin Kaczmarek
Marcin Kaczmarek

1 January 2017 in Archives of Civil and Mechanical Engineering
Verified
Journal Article
Closed access
MBMarcin Basiaga
Marcin Basiaga
WWWitold Walke
Witold Walke
Marcin StaszukMarcin Staszuk
Marcin Staszuk
WKWojciech Kajzer
Wojciech Kajzer
AKAnita Kajzer
Anita Kajzer
KNKatarzyna Nowińska
Katarzyna Nowińska

10 January 2020 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Closed access
PDF file
JJJoanna Jaworska
Joanna Jaworska
KJKatarzyna Jelonek
Katarzyna Jelonek
MJMarzena Jaworska‐Kik
Marzena Jaworska‐Kik
MMMonika Musiał-Kulik
Monika Musiał-Kulik
AMAndrzej Marcinkowski
Andrzej Marcinkowski
Janusz KasperczykJanusz Kasperczyk
Janusz Kasperczyk

1 June 2016 in Archives of Metallurgy and Materials
Verified
Journal Article
Open access
PDF file
JSJanusz Szewczenko
Janusz Szewczenko
JMJ. Marciniak
J. Marciniak
WKWojciech Kajzer
Wojciech Kajzer
AKAnita Kajzer
Anita Kajzer
The study presents the results of investigations of modeling the usable properties of implant surfaces made of Ti6Al7Nb alloy, using the example of a dynamic hip screw (DHS) applied in surgical treatment of intertrochanteric femoral neck fractures. Numerical simulation has been performed for the model load of femoral fixation with DHS screw. The load simulation results provided the basis to select mechanical properties of the fixator elements and to define those fixation areas which are mostly susceptible to development of corrosion. The surfaces of Ti6Al7Nb alloy were ground, vibro-abrasive machined, mechanically polished, sandblasted, anode oxidized at different voltage values and steam sterilized. Results of surface topography evaluation, resistance to pitting and crevice corrosion as well as degradation kinetics of the outer layer were presented. Usability of the formed passive layer in clinical applications was evaluated through wear and corrosion tests of the femoral fixation model. The test results proved usefulness of the proposed surface modification methods for clinical application of different size and shape implants

1 September 2015 in Archives of Metallurgy and Materials
Verified
Journal Article
Open access
PDF file
JMJ. Marciniak
J. Marciniak
JSJ. Szewczenko
J. Szewczenko
WKWojciech Kajzer
Wojciech Kajzer
The study discusses the methods of surface modification methods for AISAI 316 L steel and Ti6Al4V ELI titanium alloy, dedicated to complex design implants used in bone surgery. Results of structural tests have been presented along with those evaluating the physicochemical properties of the formed surface layers. Clinical feasibility of the surface layers has also been evaluated.The developed surface modification methods improved the resistance to pitting, crevice and stress corrosion and ensured better biocompatibility. Moreover, the layers formed are marked by plasticity. Results of the tests performed show applicability of the evaluated methods of surface modification in complex shape implants for the clinical use.

28 November 2020 in Archives of Civil and Mechanical Engineering
Verified
Journal Article
Open access
PDF file
MBMarcin Basiaga
Marcin Basiaga
WWWitold Walke
Witold Walke
WKWojciech Kajzer
Wojciech Kajzer
ASAgata Sambok-Kiełbowicz
Agata Sambok-Kiełbowicz
JSJanusz Szewczenko
Janusz Szewczenko
VLVira Lubenets
Vira Lubenets
The main goal of carried out tests were the impact of physicochemical properties of surface layers on the course of processes taking place on the surface of implants made of metallic biomaterials used in the bone system. As a precursor of ZnO, diethylzinc (DEZ) has been used, which reacted with water enabling the deposition of thin films. The chamber temperature was as follows—T = 200°–300 °C. The number of cycles was 500, 1000, and 1500. In the first stage, pitting corrosion test was carried out. Corrosion resistance has been tested under conditions simulating tissue environment. Moreover, the created layers were tested using electrochemical impedance spectroscopy (EIS). The conducted electrochemical tests showed the beneficial effect of the ZnO layer on the substrate made of 316 LVM steel, as evidenced by the obtained parameters describing the corrosion resistance. Furthermore, tests were performed on mechanical properties (scratch test), surface morphology (SEM and AFM method), and physical properties (wettability and thickness layers) for samples with different surface treatments. The investigations of the surface morphology of the applied ZnO layer using the ALD method showed a tendency to inherit the substrate independently of the used application parameters. On the other hand, the tests of adhesion to the substrate showed that the number of cycles of the application process has a fundamental impact on the adhesion of the applied layer to the substrate. Summarizing tests have clearly shown that the number of cycles and temperature in the case of the ZnO coating is significant and positively influences the increase of electrochemical, mechanical, and physical properties of layers.