Adel Khaleel Mahmoud

Prof. Dr. Adel Khaleel Mahmoud


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Corrosion Science
Verified
Journal Article
Closed access
AFAhmed A. Fadhil
Ahmed A. Fadhil
AKAnees A. Khadom
Anees A. Khadom
CFChaoyang Fu
Chaoyang Fu
HLHongfang Liu
Hongfang Liu
HMHameed B. Mahood
Hameed B. Mahood
AKAbdul Mun’EM A. Karim
Abdul Mun’EM A. Karim

1 January 2017 in Materials Today: Proceedings
Verified
Journal Article
Closed access
MAMuna Kh. Abbas
Muna Kh. Abbas
AMAdel Khaleel Mahmoud
Adel Khaleel Mahmoud

1 January 2024 in Material Design & Processing Communications
Verified
Journal Article
Open access
HAHiba M. Algailani
Hiba M. Algailani
SASuha I. Al-Nassar
Suha I. Al-Nassar
AMAdel Khaleel Mahmoud
Adel Khaleel Mahmoud
HAHanaa Al-Kaisy
Hanaa Al-Kaisy
AAAhmed A. A. G. Alrubaiy
Ahmed A. A. G. Alrubaiy
Metal matrix nanocomposite coatings are promising for tribological applications given their superior hardness and wear resistance compared to metals. The point of this study was to describe the shape and long‐term performance of nickel‐based coatings that were put on stainless steel using electroless codeposition and made stronger with nanoparticles of zirconia (ZrO2) and alumina (Al2O3). Scanning electron microscopy showed the uniform incorporation of nanoceramics within nickel matrices. Pin‐on‐disk tribotests evaluated wear performance across loads from 5 to 15 N and sliding speeds up to 480 cm/min. Increasing nanoparticle content from 2 to 4 g/L markedly reduced wear rate due to enhanced hardness and density. At all tested loads, Ni‐ZrO2 and Ni‐Al2O3 nanocomposites exhibited considerably lower wear than monolithic nickel. The nanometal matrix particles hindered plastic deformation, with weight losses up to 68% lower than base nickel. Initially, wear resistance rose proportionally with sliding speed resulting from protective oxide layers until abrasive wear prevailed. The nanoparticle reinforcement dramatically extended durability, making it ideal for tribological systems involving mixed or abrasive conditions. More research needs to be done to find the best compositions and other matrix materials to use for these nanoscale strengthening effects.

1 February 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
AMAdel Khaleel Mahmoud
Adel Khaleel Mahmoud
ZHZaid S. Hammoudi
Zaid S. Hammoudi
SRSamah Rasheed
Samah Rasheed
This paper aims to measuring the residual stresses practically in wear protection coatings using the sin2ψ method according to X-ray diffraction technique. The wear protection coatings used in this study was composite coating 95wt% Al2O3-5wt% SiC, while bond coat was AlNi alloy produced by using flame spraying technique on the mild steel substrate. The diffraction angle, 2θ, is measured experimentally and then the lattice spacing is calculated from the diffraction angle, and the known X-ray wavelength using Bragg's Law. Once the dspacing values are known, they can be plotted versus sin2ψ, (ψ is the tilt angle). In this paper, stress measurement of the samples that exhibit a linear behavior as in the case of a homogenous isotropic sample in a biaxial stress state is included. The plot of dspacing versus sin2ψ is a straight line which slope is proportional to stress. On the other hand, the second set of samples showed oscillatory dspacing versus sin2ψ behaviour. The oscillatory behaviour indicates the presence of inhomogeneous stress distribution. In this case the X-ray elastic constants must be used instead of Young's modulus (E) and Poisson ratio (ν)values. These constants can be obtained from the literature for a given material and reflection combination. The value of the residual stresses for the present coating calculated was compressive stresses (-325.6758MPa).


1 March 2023 in Diyala Journal of Engineering Sciences
Verified
Journal Article
Open access
PDF file
BZBasma Z.Thabeta
Basma Z.Thabeta
SASuha I. Al-Nassarb
Suha I. Al-Nassarb
HAHiba M. Algailani
Hiba M. Algailani
AMAdel Khaleel Mahmoud
Adel Khaleel Mahmoud
RNRamdziah Nasir
Ramdziah Nasir
AAAhmed Aag Alrubaiy
Ahmed Aag Alrubaiy
Silver-hydroxyapatite (Ag-HA) nanocomposite coating on stainless steel (316L) sheets was prepared by electroless deposition. Several studies have analysed the influence of bath composition on the corrosion behaviour of Ag-HA bio-nanocomposite coating produced by electroless deposition. Therefore, the present study compared the influence of varying concentrations of HA nanoparticles (0.1, 0.3, and 0.5) g/L on the mechanical (microhardness) and chemical (corrosion resistance and ion release) properties of the Ag-HA nanocomposite coating. The Ag-HA nanocomposite coating exhibited a remarkable increase in microhardness from 104.7 Hv to 139.9 Hv at 0.5 g/L HA nanoparticles and improved corrosion resistance, where the corrosion rate was enhanced for the coating from 5.954×10-1 mpy to 2.633×10-2 mpy in the presence of nano-HA. The ion release analysis of the element coating revealed that the nickel content was within the permissible limit in accordance with the amount of Ni permitted to exist inside the human body, and chromium was not found.