NIK NUR AIN AZRIN ABDULLAH

Ms. NIK NUR AIN AZRIN ABDULLAH

Biomedical Engineering and Health Sciences, Universiti Teknologi Malaysia, Johor Bahru, Johor, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2023 in Materials
Verified
Journal Article
Open access
PDF file
ZSZatul Faqihah Mohd Salaha
Zatul Faqihah Mohd Salaha
Muhammad Imam AmmarullahMuhammad Imam Ammarullah
Muhammad Imam Ammarullah
NIK NUR AIN AZRIN ABDULLAHNIK NUR AIN AZRIN ABDULLAH
NIK NUR AIN AZRIN ABDULLAH
AAAishah Umairah Abd Aziz
Aishah Umairah Abd Aziz
HGHong Seng Gan
Hong Seng Gan
Muhammad Hanif RamleeMuhammad Hanif Ramlee
Muhammad Hanif Ramlee
Total hip arthroplasty (THA) is most likely one of the most successful surgical procedures in medicine. It is estimated that three in four patients live beyond the first post-operative year, so appropriate surgery is needed to alleviate an otherwise long-standing suboptimal functional level. However, research has shown that during a complete THA procedure, a solid hip implant inserted in the femur can damage the main arterial supply of the cortex and damage the medullary space, leading to cortical bone resorption. Therefore, this study aimed to design a porous hip implant with a focus on providing more space for better osteointegration, improving the medullary revascularisation and blood circulation of patients. Based on a review of the literature, a lightweight implant design was developed by applying topology optimisation and changing the materials of the implant. Gyroid and Voronoi lattice structures and a solid hip implant (as a control) were designed. In total, three designs of hip implants were constructed by using SolidWorks and nTopology software version 2.31. Point loads were applied at the x, y and z-axis to imitate the stance phase condition. The forces represented were x = 320 N, y = −170 N, and z = −2850 N. The materials that were used in this study were titanium alloys. All of the designs were then simulated by using Marc Mentat software version 2020 (MSC Software Corporation, Munich, Germany) via a finite element method. Analysis of the study on topology optimisation demonstrated that the Voronoi lattice structure yielded the lowest von Mises stress and displacement values, at 313.96 MPa and 1.50 mm, respectively, with titanium alloys as the materials. The results also indicate that porous hip implants have the potential to be implemented for hip implant replacement, whereby the mechanical integrity is still preserved. This result will not only help orthopaedic surgeons to justify the design choices, but could also provide new insights for future studies in biomechanics.

17 April 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
BNBing Wui Ng
Bing Wui Ng
AWAbdul Hadi Abdul Wahab
Abdul Hadi Abdul Wahab
AWAbdul Muttalib Abdul Wahid
Abdul Muttalib Abdul Wahid
NIK NUR AIN AZRIN ABDULLAHNIK NUR AIN AZRIN ABDULLAH
NIK NUR AIN AZRIN ABDULLAH
MKMohammed Rafiq Abdul Kadir
Mohammed Rafiq Abdul Kadir
Muhammad Hanif RamleeMuhammad Hanif Ramlee
Muhammad Hanif Ramlee
External fixators have been used effectively in damage control orthopaedic and open fractures management of various bones. It is well known that stability of external fixators is greatly influenced by its construct. Various rules have been documented to influence the stiffness and stability of external fixators. In this study, two clinical cases treated with a novel concept of cross self-locking rods external fixation construct were being described, coupled with biomechanical analysis of its stability in comparison with other constructs by using finite element study. These novel self-locking rods configuration proven improve strength by applying the same numbers of rod and pin with the delta frame construct in clinical practice. A validated three-dimensional (3D) model of the bone from a previous study was used and external fixator were designed via computer-aided design (CAD) modelling software, Solidworks. A 1500 N load representing the axial load compression during weight bearing was applied to the tibia with the distal segment of the fracture site secured without any movement. The clinical results showed bone healing process with both cases achieving bone union within the acceptable time. The results of the finite element study shows that the double cross self-locking rods construct had better stability since it showed optimum magnitude in relative micromotion (0.18 mm), lowest stress at the fracture site (189 MPa), displacement of fixator (13.4 mm), and stress at the fixator (687 MPa). In conclusion, double cross self-locking design could provide optimum stability of the external fixator construct by providing better stress distribution at the bone and external fixator, minimize displacement and micromotion at fracture fragments.

27 June 2026 in Injury
Verified
Journal Article
Closed access
MBMuhammad Hanif Baharuddin
Muhammad Hanif Baharuddin
NIK NUR AIN AZRIN ABDULLAHNIK NUR AIN AZRIN ABDULLAH
NIK NUR AIN AZRIN ABDULLAH
MKMohamad Ikhwan Kori
Mohamad Ikhwan Kori
HGHong-Seng Gan
Hong-Seng Gan
MKMohammed Rafiq Abdul Kadir
Mohammed Rafiq Abdul Kadir
Muhammad Hanif RamleeMuhammad Hanif Ramlee
Muhammad Hanif Ramlee